• 24 Volt Culligan’s MVP™ Controller – Field
programmable with a back-lit LCD display and
UL listed 120v/24v transformer.
• Single,Duplex, Triplex, or Quad Configurations
• Regeneration initiation by choice of time clock,
meter or differential pressure switch.
• Carbon Filters – For reduction of organics (flow
rates up to 39gpm), or chlorine (flow rates up to
77gpm).
• Depth Filters – Flow rates up to 193gpm.
• Top-Mounted Control Valve – Keeps plumbing
connections simple and adaptable. Full flow
porting with rounded orifices and wide-open
cartridges promote good flow characteristics and
low pressure fluctuations.
• Corrosion resistant tanks – Made oflow carbon
steel with epoxy interior lining and finish coat
painted exterior.
Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other
countries. Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice. , Brunermatic, Hey Culligan Man,
Culligan Man, Culligan Commercial @ Work, www.culligan.com and Culligan Service Network are trademarks of Culligan International Company or its affiliates.
Superior – Best quality water with lowest pressure loss. Recommended for influent suspended solid loads up to and g reater than 300 ppm.
**
High – Very good quality water with increased pressure loss.Recommended for influent suspended solid loads less than 300 ppm.
***
Utility – Satisfactory quality water with greatest pressure loss.Shorter on line time between backwashing.Recommended for influent suspended solid
loads less than 150 ppm.
1
For Sediment and organic removal use the flow rates from the superior water quality column.
2
For chlorine removal only, use the flow rates from the utility water quality column.
All pressure drop figures are based on new filter media and a water temperature of60°F.
Depth filters are capable of 10 micron effluent water quality,whereas all other filter types are capable of 40 micron effluent water quality.
Water Qualit y
High
**
Utility
***
Depth Filters
Carbon Filters
System Specifications
Pressure:30–100 psig
207–690 kPa
Power:120 VAC/24 VAC
50/60 Hz
Temperature:40–120°F
4–49°C
Applications and Benefits
• Food and Beverage–Superior taste and increased
cost savings.
• Drinking Water–Reduces turbidity and chlorine;
improves taste and clarity.
• Boilers—Turbidit y reduction, minimize sludge
blowdown.
• Light Industry Processes—Reduces particulate matter.
• Pretreatment—For softeners,RO’s and DI systems.
• Vehicle Wash—Turbidity reduction.
Options
• Patented Prog ressive FlowCulligan’s MVP™ controller can
monitor flow demands,bring ing
additional tanks on-line or off-line
as flows increase or decrease.
• Differential Pressure Switch
• A.S.M.E. Code Tanks
• Sample cocks and pressure gauges
• Separate source regeneration kits
• Skid mounting
• Flow meter
Warranty
Culligan’s Hi-Flo55e water filters are
backed by a limited 1-year warranty
against defects in material,
workmanship and corrosion.In
addition, tanks carry a limited 5-year
warranty.*
* See printed warranty for details.
Culligan will provide a copy of the
warranty upon request.
NOTES:
1 Service flow rates are based on 7 gpm/ft2 (26 L/m2/min) for Normal and 15 gpm/ft2 (57 L/m2/min) for Peak Flow rates. Actual service rate can vary from
2 to 20 gpm/ft2 (8 - 76 L/m2/min) depending upon the application and the raw water.
2 Backwash flow rates are based on 12-14 gpm/ft2 (45-53 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature or the type of carbon used.
3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently
NOTES:
1 Service flow rates are based on 5 gpm/ft2 (19 L/m2/min) for Organic Adsorption and 10 gpm/ft2 (38 L/m2/min) for Dechlorination. Actual flow rate may vary
depending upon the application and the raw water.
2 Backwash flow rates are based on 10 gpm/ft2 (38 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature or the type of carbon used.
3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently
NOTES:
1 Service flow rates are based on 5 gpm/ft2 (19 L/m2/min). Actual flow rate may vary depending upon the application and the raw water.
2 Backwash flow rates are based on 12-14 gpm/ft2 (45-53 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon
water temperature or other water conditions.
3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently