CTS WAC-2112 SERIES User Manual

Trademarks
CTS is a registered trademark of Connection Technology Systems Inc.. Contents subject to revision without prior notice. All other trademarks remain the property of their owners.
Copyright Statement
Copyright Connection Technology Systems Inc. This publication may not be reproduced as a whole or in part, in any way whatsoever
FCC Warning
WAC-2112 Series Media Converters have been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These standards are designed to provide reasonable protection against harmful interference when these devices are operated in a commercial environment. These devices generate, use, and can radiate radio frequency energy and may cause harmful interference to
radio communications unless installed in accor dance with this User’s Guide. Operation
of these devices in a residential area is likely to cause harmful interference which will make the user responsible for the appropriate remedial action at his / her own expense.
CE Mark Warning
These are Class A products. In a domestic environment these products may cause radio interference in which case the user will need to consider adequate preventative methods.
1. Checklist
The package should contain the following items:
-
WAC-2112 Media Converter
-
CD (Users Manual and MIB file)
-
Power Adaptor (Optional)*
-
Users Guide and Installation Guide
*For detailed information, please refer to Section 9.
Please notify your sales representative immediately if any item is missing or damaged.
2. Overview
WAC-2112 Series Media Converters are designed to meet the massive needs for Fast Ethernet network deployments and aim at industrial applications that demand wide range of operating temperature. WAC-2112 Media Converters are fully compliant with IEEE802.3, 802.3u and 802.3x standards. Via single mode fiber cable, they are able to extend a copper-based network to a maximum distance up to 100KM.
Besides, redundant AC and DC power supplies are both offered on WAC-2112 Series Media Converters for users to create a reliable and stable network in the event of power failure. They can also be mounted on the wall or onto 35mm DIN rail using DIN rail clip on the media converter. The installation and operation procedures are simple and straightforward. Operation status can be locally monitored through a set of diagnostic LED indicators located on the front panel.
Major Features:
-
Auto-Negotiation in TP port
-
Store and Forward Switching Mechanism
-
Support MDI/MDIX Auto-Crossover
-
Support Flow Control
-
Support Link Alarm
-
Support alarms for power and port failure
-
Support 1K MAC address
-
Support 9K bytes Jumbo Frame
-
Support redundant AC and DC power supply
-
Support wide range of operating temperature (-20oC ~60oC)
-
Support DIN Rail and Wall Mounting
3. Network Installation
-
Attach fiber cable from WAC-2112 to the fiber network.
-
Attach a UTP cable from the 10/100Base-TX network to the RJ-45 port on WAC-2112.
-
Connect the power adaptor to WAC-2112 and check that the Power LED lights up. The TP Link/ACT and F/O Link/ACT LED will light up when all the cable connections are satisfactory.
Figure 1. Basic Network Connection for BTFX Series.
Figure 2. Basic Network Connection for WDM/SFP Series
4. DIP SWITCH Setting
WAC-2112 Series Media Converters provide users with a DIP Switch to configure switching functions. The DIP Switch is located at the bottom of the media converter and the default setting of all pins is OFF.
Figure 2. Terminal Block and DIP Switch (Bottom Panel)
Pin NO.
Function
OFF
ON
1
Speed 1
Auto-Negotiation
(Pin 2 OFF)
10M
(Pin 2 OFF)
2
Speed 2
-
100 M 3 Flow Control
Disable
Enable 4 Reserved
Always OFF
5
Reserved
Always OFF
6
Link Alarm
Disable
Enable
7
TP Configuration
From S/W
From DIP
8
F/O Fault Alarm
Disable
Enable 9 TP Fault Alarm
Disable
Enable
NOTE: 1. Pin 1 and 2 must be set together to configure the speed.
2. Please perform Power On reset after modifying the DIP Switch setting.
5. Terminal Block
TB1 and TB2 Power Supply: There are two pairs of contacts
(TB1 and TB2) on the terminal block connector for power redundancy purpose. You can use both pairs of power supply for redundancy purpose or use either one pair of power supply on the terminal block and AC external power supply to create redundant setup. The redundant power supply will take over seamlessly when one power source is down to protect your device or network from the loss of power. When you use only one power supply (no redundant power is available), the LED Power/Port Status will flash in orange to alert the user.
Port Fault Alarm: One pair of port fault connection on the terminal block is used to connect alarm devices such as speakers or LED to alert users when TP or F/O port link is disconnected. To make this function work, you must first set pin 8 and 9 on the DIP Switch to ON position (Enable).
Figure 4. Terminal Block Front and Top View
6. Link Alarm
Link Alarm allows users to easily identify and diagnose the linking status. If Link Alarm DIP switch is set to Enable, TP and F/O can link up only when both linking conditions are good. In addition, if the TP or F/O port link is down during operation, the other port will also be turned down to alert the user. Setting Link Alarm DIP switch to Enable gives the user a transparent link indication between two network devices interconnected by WAC-2112.
Connect to 10/100BASE-TX Network
Connect to SC/ST 100BASE-FX Fiber Network
TX/RX
TX RX
Connect to 10/100BASE-TX Network
Connect to 100BASE-FX Fiber Network
Terminal Block
DIP Switch
Use flat-head screwdriver to loosen and tighten the screw.
Insert positive or negative wire as indicated.
If Link Alarm is disabled, the TP and F/O will link up based on their individual linking condition. Furthermore, if either port link (TP or F/O) is down during operation, it will not turn down the other port
link.
7. LED Description
8. Technical Specifications
Standards
IEEE 802.3, 802.3u, 802.3x
Interface
1 X 10/100 RJ-45 connector 1 X 100 SC/ST F/O port or SFP slot
LED
PW ADC, PW T1, PW T2, TP Link/ACT, Speed, FDX, F/O Link/ACT, PWR/Port Status
Power
DC Input Voltage: 12/48VDC DC Power Jack x 1; DC Terminal Block x 2
Shipping Weight
0.275KG
Dimensions
105mm(W)X93mm(D)X35mm(H)
Temperature
Operating: -20oC ~60oC; Storage: -20oC ~70oC
Humidity
5%~90% RH non-condensing
EMC Safety
FCC Part 15 Class A, CE
Media TP:
EIA/TIA-568 CAT 5e
Fiber:
50/125, 62.5/125um multi-mode fiber 9/125, 10/125um single-mode fiber
*Please contact us for further reports and updates.
9. Optional Accessory
Power Adapters:
Fiber Transceiver Information
100M Multi-Mode
TYPE
BTFC
BTFT
Connector Type
SC
ST
Wavelength
1310nm
1310nm
Typical Distance
2Km
2Km
Min TX PWR
-20.0dBm
-20.0dBm
Max TX PWR
-14.0dBm
-14.0dBm
Sensitivity
-31.0dBm
-31.0dBm
Link Budget
11.0dB
11.0dB
Single-Mode
TYPE
BTFC
(SM-30)
BTFC
(SM-50)
BTFC
(SM-80)
BTFC
(SM-100)
Connector Type
SC
SC
SC
SC
Wavelength
1310nm
1310nm
1310nm
1550nm
Typical Distance
30Km
50Km
80Km
100Km
Min TX PWR
-15.0dBm
-5.0dBm
0dBm
-5.0dBm
Max TX PWR
-8.0dBm
0dBm
5.0dBm
0dBm
Sensitivity
-34.0dBm
-35.0dBm
-36.0dBm
-35.0dBm
Link Budget
19.0dB
30.0dB
36.0dB
30.0dB
Wave-Length WDM
TYPE
W2A
(SM-20)
W2B
(SM-20)
W2A
(SM-40)
W2B
(SM-40)
Connector Type
SC
SC
SC
SC
TX Wavelength
1310nm
1550nm
1310nm
1550nm
RX Wavelength
1550nm
1310nm
1550nm
1310nm
Typical Distance
20 Km
20 Km
40 Km
40 Km
Min TX PWR
-14.0dBm
-14.0dBm
-8.0dBm
-8.0dBm
Max TX PWR
-8.0dBm
-8.0dBm
0dBm
0dBm
Sensitivity
-31.0dBm
-31.0dBm
-34.0dBm
-34.0dBm
Link Budget
17.0 dB
17.0 dB
26.0 dB
26.0 dB
NOTE: Specifications may change without prior notice.
Contact Information
Connection Technology Systems INC (CTS)
18F-6, No.79, Sec.1, Xintai 5th Rd., Xizhi Dist., New Taipei City 221, TAIWAN, R.O.C. TEL: +886 2 26989661 FAX: +886 2 26989662 E-Mail: info@ctsystem.com
WAC-2112 SERIES
10/100Base-TX to 100Base-FX Fast Ethernet Managed Media Converter
with Extended Operating
Temperature
User’s Guide
Version 1.3
LED
Color
Function
PW ADC
Green
AC or DC power is available.
PW T1
Green
Terminal Block 1 powers up.
PW T2
Green
Terminal Block 2 powers up.
TP
Link/ACT Green
TP link is up.
Blinking
Green
TP is receiving and transmitting data.
Speed
Off
Link is down or TP works in 10M.
Green
TP works in 100M.
FDX
Off
TP port works in half duplex mode.
Green
TP port works in full duplex mode.
F/O
Link/ACT Green
F/O link is up.
Blinking
Green
F/O is receiving and transmitting data.
PWR/Port
Status
Orange
TP or F/O link is down. (This indication only works when DIP 8 and 9 are set to Enable.)
Blinking
Orange
Redundancy system is abnormal (only one power source is available).
MODEL
Connector Type
Volt/Watt
WAP-POWER-12J18
DC Jack
12V/18W
WAP-POWER-48J90
DC Jack
48V/90W
WAP-POWER-48D75
Terminal Block
48V/75W
WAP-POWER-48D240
Terminal Block
48V/240W
Loading...