MCN MCN RYB-8 Relay Board
Hardware Manual
S2-60657-100
68-11206-100
Standard Limited Hardware Warranty
LIMITED WARRANTY.
of ONE (1) YEAR from date of shipment to original purchaser. Under this warranty, our obligation is limited to repairing or replacing any equipment
proved to be defective by our inspection within one year of sale to the original purchaser. This warranty shall not apply to equipment which has been
repaired outside our plant in any way, so as to, in the judgment of CTI Products, Inc. affect its stability or reliability, nor which has been operated in a
manner exceeding its specifications, nor which has been altered, defaced, or damaged by lightning.
Equipment manufactured by CTI Products, Inc. is warranted to be free from defects in material and workmanship for a period
CUSTOMER REMEDIES
the customer shall call CTI Products, Inc. to obtain a Return Authorization Number and return the product or module, shipping and insurance prepaid. CTI
Products, Inc., will then at its option, either repair or replace the product or module and return it, shipping prepaid, or refund the purchase price thereof.
On-site labor at the purchaser's location is not included in this warranty.
EQUIPMENT NOT MANUFACTURED BY CTI Products, Inc.
but is subject to the warranty provided by its manufacturer, a copy of which will be supplied to you upon specific written request.
NO OTHER WARRANTIES.
IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR
PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS OR ANY OTHER MATTER.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES.
OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR
OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE CTI PRODUCTS, INC. EQUIPMENT BY PURCHASER OR
OTHER THIRD PARTY, WHETHER UNDER THEORY OF CONTRACT, TORT (INCLUDING NEGLIGENCE), INDEMNITY, PRODUCT LIABILITY
OR OTHERWISE, EVEN IF CTI PRODUCTS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. IN NO
EVENT SHALL CTI PRODUCTS, INC.’S, LIABILITY EXCEED THE TOTAL AMOUNT PAID BY PURCHASER FOR THE EQUIPMENT GIVING
RISE TO SUCH LIABILITY.
. In the event of a defect, malfunction, or failure to conform to specifications established by the seller during the period shown,
Equipment not manufactured by CTI Products, Inc. is excluded from this warranty,
The foregoing constitutes the sole and exclusive remedy of the buyer and exclusive liability of CTI Products, Inc., AND IS
WITHOUT LIMITING THE FOREGOING, IN NO EVENT SHALL CTI PRODUCTS, INC.
CTI Products, Inc.
1211 W. Sharon Rd.
Cincinnati, OH 45240
If you have questions about this equipment, call us at:
(513) 595-5900. (8:30 to 5:00 Eastern)
Information contained in this document is subject to change without notice and does not represent a commitment on the part of CTI Products, Inc.
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for
any purpose without the written permission of CTI Products, Inc.
Copyright 1996, CTI Products, Inc. All rights reserved.
MCN is a trademark of CTI Products, Inc. Other trademarks referenced are properties of their respective owners.
2
CTI Products, Inc. MCN RYB-8 Relay Board Manual
1. INTRODUCTION...............................................................................................1
1.1 R
ELATED DOCUMENTS
.......................................................................................1
2. CIRCUIT DESCRIPTION ..................................................................................2
2.1 R
ELAY CONTROL INPUTS
2.2 S
UB-CATEGORY JUMPERS
2.3 A
DJACENT RELAY DRIVE JUMPERS
2.4 600 O
HM TERMINATION JUMPERS
E1-E8 “B” S
E1-E8 “A” S
E17-E23.......................................................3
E9-E16..........................................................4
...........................................................2
IDE
.........................................................3
IDE
3. JUMPER LIST ..................................................................................................5
3.1 P
OWER INPUT
3.2 R
ELAY OUTPUT CONNECTIONS
3.3 R
ELAY INPUT CONNECTIONS
-- TB1 ........................................................................................5
-- J1 ...................................................................6
-- J2.......................................................................7
4. MOUNTING AND CABLING.............................................................................9
5. SPECIFICATIONS ..........................................................................................11
6. SCHEMATIC...................................................................................................12
7. BOARD LAYOUT............................................................................................13
68-11206-100
i
This page intentionally left blank
ii
CTI Products, Inc. MCN RYB-8 Relay Board Manual
1. Introduction
The MCN-RYB-8 board is a relay board accessory to the MCN Monitoring and
Control Network product family.
The MCN-RYB-8 board has the following features:
• (8) DPDT Relays (Configured to switch circuit pairs).
• Hi-reliability long-life sealed relays.
• Relays rated for low-level (dry circuit) audio switching, up to 2A.
• Selectable 600 Ohm terminations for the Normally Open, Normally Closed, or
Common circuits (may be de-selected).
• LEDs to indicate which relays are active.
• Control Connector (relay coil inputs) which is pin-compatible with the MCN
IOB modules.
• 25-pair telco connectors used for control inputs and relay outputs.
• Jumpers to control adjacent relays.
• Jumpers for Sub-Category strapping for MCNRCD variable status text
messages.
• Optional EIA 19” rack-mount panel available for mounting (4) MCN-RYB-8
boards.
Part Number Description
S3-60644 Basic board with no jumpers installed
S2-60694 Board with standard jumpers installed
E1-E8: B1 installed (I/O Line 1 controls relays)
E9-E16: (2) jumpers installed in park position
S2-XXXXX Board with custom jumpering
Note: The MCN RYB-8 Relay board is pin-compatible with the IOB module and
is fully supported for operation with it. Although it is also pin- compatible with
the CIB Comparator Interface Module (in Spectra-TAC mode only), it is not
supported for use with CIB modules. References are made within this document
to the CIB Comparator Interface Module only for completeness, especially with
the MCNRCD PC Software.
1.1 Related Documents
1. MCN IOB Input/Output Control Module
Part Number S2-60630
2. MCN System Manual
Part Number S2-60425
3. MCN Remote Comparator Display (MCNRCD) Manual
Part Number S2-60428
B4 installed (Spare sub-category jumper, parked)
(600 Ohm Termination de-selected)
1
68-11206-100
MCN RYB-8 Relay Board Manual CTI Products, Inc.
2. Circuit Description
The MCN-RYB-8 board has 8 identical circuits. The following will describe the
first such circuit.
Relay K1 has the following I/O bits associated with it:
J2
Relay I/O Bit Relay Board
Pin
21 1 1 Input/Output VOTE 1 Input/Output 1
22 1 2 Output RECEIVE 1 input 1
20 1 3 Input/Output DISABLE 1 Input/Output 9
23 1 4 Output FAIL 1 input 9
Function
I/O bits 1 or 3 can be used as inputs to drive the coil of the relay (see Figure 1).
2.1 Relay Control Inputs E1-E8 “B” Side
Each relay has its own jumper block (E1-E8) to select the input that will drive the
relay coil. Each relay can be controlled from either I/O bit 1 or 3 associated with
it, depending upon the position of the B1 or B3 jumper in jumper blocks E1-E8.
The following table shows the jumper configuration for relay K1:
CIB Module
Signal
IOB Mode 1
Signal
J2 Pin I/O Bit Jumper
21 1 E1-B1 In (Default)
20 3 E1-B3 In
Only one jumper (E1-B1 or E1-B3) should be installed at a time.
I/O BIT
VOTE
RX
DIS
FAIL
JUMPER POSITIONS FOR
SUB-CATEGORY JUMPERING
Figure 1 Input Jumpering E1-E8
Positions B2 and B4 can be used to "park" unused jumpers.
A
B
1
2
3
4
DEFAULT POSITION
I/O BIT 1 DRIVES RELAY
B2 PARKING FOR UNUSED JUMPER
ALTERNATE POSITION
I/O BIT 3 DRIVES RELAY
B4 PARKING FOR UNUSED JUMPER
CA-80270-100
2