of ONE (1) YEAR from date of shipment to original purchaser. Under this warranty, our obligation is limited to repairing or replacing any equipment
proved to be defective by our inspection within one year of sale to the original purchaser. This warranty shall not apply to equipment which has been
repaired outside our plant in any way, so as to, in the judgment of CTI Products, Inc. affect its stability or reliability, nor which has been operated in a
manner exceeding its specifications, nor which has been altered, defaced, or damaged by lightning.
Equipment manufactured by CTI Products, Inc. is warranted to be free from defects in material and workmanship for a period
CUSTOMER REMEDIES
the customer shall call CTI Products, Inc. to obtain a Return Authorization Number and return the product or module, shipping and insurance prepaid. CTI
Products, Inc., will then at its option, either repair or replace the product or module and return it, shipping prepaid, or refund the purchase price thereof.
On-site labor at the purchaser's location is not included in this warranty.
EQUIPMENT NOT MANUFACTURED BY CTI Products, Inc.
but is subject to the warranty provided by its manufacturer, a copy of which will be supplied to you upon specific written request.
NO OTHER WARRANTIES.
IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR
PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS OR ANY OTHER MATTER.
NO LIABILITY FOR CONSEQUENTIAL DAMAGES.
OR ITS SUPPLIERS BE LIABLE FOR ANY DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES OR FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, OR
OTHER PECUNIARY LOSS) ARISING OUT OF THE USE OF OR INABILITY TO USE CTI PRODUCTS, INC. EQUIPMENT BY PURCHASER OR
OTHER THIRD PARTY, WHETHER UNDER THEORY OF CONTRACT, TORT (INCLUDING NEGLIGENCE), INDEMNITY, PRODUCT LIABILITY
OR OTHERWISE, EVEN IF CTI PRODUCTS, INC. HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. IN NO
EVENT SHALL CTI PRODUCTS, INC.’S, LIABILITY EXCEED THE TOTAL AMOUNT PAID BY PURCHASER FOR THE EQUIPMENT GIVING
RISE TO SUCH LIABILITY.
. In the event of a defect, malfunction, or failure to conform to specifications established by the seller during the period shown,
Equipment not manufactured by CTI Products, Inc. is excluded from this warranty,
The foregoing constitutes the sole and exclusive remedy of the buyer and exclusive liability of CTI Products, Inc., AND IS
WITHOUT LIMITING THE FOREGOING, IN NO EVENT SHALL CTI PRODUCTS, INC.
CTI Products, Inc.
1211 W. Sharon Rd.
Cincinnati, OH 45240
If you have questions about this equipment, call us at:
(513) 595-5900. (8:30 to 5:00 Eastern)
Information contained in this document is subject to change without notice and does not represent a commitment on the part of CTI Products, Inc.
No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for
any purpose without the written permission of CTI Products, Inc.
Copyright 1996, CTI Products, Inc. All rights reserved.
MCN is a trademark of CTI Products, Inc. Other trademarks referenced are properties of their respective owners.
The MCN-RYB-8 board is a relay board accessory to the MCN Monitoring and
Control Network product family.
The MCN-RYB-8 board has the following features:
• (8) DPDT Relays (Configured to switch circuit pairs).
• Hi-reliability long-life sealed relays.
• Relays rated for low-level (dry circuit) audio switching, up to 2A.
• Selectable 600 Ohm terminations for the Normally Open, Normally Closed, or
Common circuits (may be de-selected).
• LEDs to indicate which relays are active.
• Control Connector (relay coil inputs) which is pin-compatible with the MCN
IOB modules.
• 25-pair telco connectors used for control inputs and relay outputs.
• Jumpers to control adjacent relays.
• Jumpers for Sub-Category strapping for MCNRCD variable status text
messages.
• Optional EIA 19” rack-mount panel available for mounting (4) MCN-RYB-8
boards.
Part NumberDescription
S3-60644Basic board with no jumpers installed
S2-60694Board with standard jumpers installed
E1-E8:B1 installed (I/O Line 1 controls relays)
E9-E16:(2) jumpers installed in park position
S2-XXXXXBoard with custom jumpering
Note: The MCN RYB-8 Relay board is pin-compatible with the IOB module and
is fully supported for operation with it. Although it is also pin- compatible with
the CIB Comparator Interface Module (in Spectra-TAC mode only), it is not
supported for use with CIB modules. References are made within this document
to the CIB Comparator Interface Module only for completeness, especially with
the MCNRCD PC Software.
1.1 Related Documents
1. MCN IOB Input/Output Control Module
Part Number S2-60630
2. MCN System Manual
Part Number S2-60425
3. MCN Remote Comparator Display (MCNRCD) Manual
Part Number S2-60428
B4 installed (Spare sub-category jumper, parked)
(600 Ohm Termination de-selected)
1
68-11206-100
MCN RYB-8 Relay Board Manual CTI Products, Inc.
2. Circuit Description
The MCN-RYB-8 board has 8 identical circuits. The following will describe the
first such circuit.
Relay K1 has the following I/O bits associated with it:
I/O bits 1 or 3 can be used as inputs to drive the coil of the relay (see Figure 1).
2.1 Relay Control Inputs E1-E8 “B” Side
Each relay has its own jumper block (E1-E8) to select the input that will drive the
relay coil. Each relay can be controlled from either I/O bit 1 or 3 associated with
it, depending upon the position of the B1 or B3 jumper in jumper blocks E1-E8.
The following table shows the jumper configuration for relay K1:
CIB Module
Signal
IOB Mode 1
Signal
J2 PinI/O BitJumper
211E1-B1 In (Default)
203E1-B3 In
Only one jumper (E1-B1 or E1-B3) should be installed at a time.
I/O BIT
VOTE
RX
DIS
FAIL
JUMPER POSITIONS FOR
SUB-CATEGORY JUMPERING
Figure 1 Input Jumpering E1-E8
Positions B2 and B4 can be used to "park" unused jumpers.
A
B
1
2
3
4
DEFAULT POSITION
I/O BIT 1 DRIVES RELAY
B2 PARKING FOR UNUSED JUMPER
ALTERNATE POSITION
I/O BIT 3 DRIVES RELAY
B4 PARKING FOR UNUSED JUMPER
CA-80270-100
2
CTI Products, Inc.MCN RYB-8 Relay Board Manual
2.2 Sub-Category Jumpers E1-E8 “A” Side
When you use the MCN Relay Board with an MCN IOB module and the
MCNRCD PC Software, you can use the “A” side of jumper blocks E1 through
E8 to provide static sub-category status text selections. This will allow you to
specify different status text messages (On/Off, Up/Down, Main/Standby, etc. as
defined in the MCNRCD.CFG file) for different relays on the MCN-RYB-8
board.
Since I/O bit 1 is normally used to control the relay, I/O bits 2-4 are available for
sub-category selection. Up to (8) sub-categories can be configured with these 3
bits. When a jumper is inserted, the bit is active. See the MCNRCD Software
Manual and IOB hardware manual for more details on sub-categories.
2.3 Adjacent Relay Drive Jumpers E17-E23
In some applications you may need to drive two relays from the same input signal.
You can use jumpers E17-E23 to connect a relay's coil to an adjacent relay's coil.
E17 jumpers the coils for relays 1 & 2 together. E18 jumpers relays 2 & 3, and so
on.
MCNRCD
Bit Weight
Caution
When you insert the Adjacent Relay Drive jumpers (E17-E23), be sure that you
have only one input active (E1-E8 "B" side) for each set of relays that are
connected together.
These jumpers are normally not installed from the factory, unless a custom
configuration is ordered.
3
68-11206-100
MCN RYB-8 Relay Board Manual CTI Products, Inc.
2.4 600 Ohm Termination Jumpers E9-E16
A selectable 600 Ohm termination is available for each relay. The termination is
used in some telephone line applications when you need to terminate an unused
phone line. Jumper blocks E9 to E16 control the terminations. You can terminate
the Normally Open, Normally Closed, or Common pair as shown in Table 2 and
Figure 2
600 Ohm TerminationE9-E16 Jumpers Installed
NoneNone (or insert in "Park" positions)
Common PairA1 & B1
Normally Open PairA2 & B2
Normally Closed PairA4 & B4
Table 2 - 600 Ohm Termination Jumpering
1
B
---------------
A
12
23
4
TERMINATE
COMMON PAIR
34
1
23
B
---------------
A
12
1
23
B
---------------
A
12
1
23
B
---------------
A
12
4
TERMINATE
N.O. PAIR
34
4
TERMINATE
N.C. PAIR
34
4
NO TERMINATION
(PARKING FOR UNUSED JUMPERS)
34
CA-80272-100
Figure 2 600 Ohm Termination Jumpering E9-E16
4
CTI Products, Inc.MCN RYB-8 Relay Board Manual
3. Jumper List
JumperControls
Relay
E11Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E22Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E33Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E44Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E55Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E66Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E77Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E88Input Select (B1 & B3) and Sub-Category Jumpering (A1-A4)
E91600 Ohm Termination Selection
The board requires 12V external power at 704 mA. Power is applied through
screw terminal block TB1 as shown in Table 4.
TB1 PinFunction
1+12V
2+12V (can be used to daisy-chain power)
3Ground
4Ground (can be used to daisy-chain power)
Table 4 - Power Connections TB1
5
68-11206-100
MCN RYB-8 Relay Board Manual CTI Products, Inc.
3.2 Relay Output Connections -- J1
The relay output connections appear on a 50-pin female micro-ribbon telco style
connector, J1. The pinouts are as follows:
J1 PinFunction
26K1 Tip Common
1K1 Ring Common
27K1 Tip Normally Open (N.O.)
2K1 Ring Normally Open (N.O.)
28K1 Tip Normally Closed (N.C.)
3K1 Ring Normally Closed (N.C.)
29K2 Tip Common
4K2 Ring Common
30K2 Tip Normally Open (N.O.)
5K2 Ring Normally Open (N.O.)
31K2 Tip Normally Closed (N.C.)
6K2 Ring Normally Closed (N.C.)
32K3 Tip Common
7K3 Ring Common
33K3 Tip Normally Open (N.O.)
8K3 Ring Normally Open (N.O.)
34K3 Tip Normally Closed (N.C.)
9K3 Ring Normally Closed (N.C.)
35K4 Tip Common
10K4 Ring Common
36K4 Tip Normally Open (N.O.)
11K4 Ring Normally Open (N.O.)
37K4 Tip Normally Closed (N.C.)
12K4 Ring Normally Closed (N.C.)
38K5 Tip Common
13K5 Ring Common
39K5 Tip Normally Open (N.O.)
14K5 Ring Normally Open (N.O.)
40K5 Tip Normally Closed (N.C.)
15K5 Ring Normally Closed (N.C.)
41K6 Tip Common
16K6 Ring Common
42K6 Tip Normally Open (N.O.)
17K6 Ring Normally Open (N.O.)
43K6 Tip Normally Closed (N.C.)
18K6 Ring Normally Closed (N.C.)
44K7 Tip Common
19K7 Ring Common
45K7 Tip Normally Open (N.O.)
20K7 Ring Normally Open (N.O.)
46K7 Tip Normally Closed (N.C.)
21K7 Ring Normally Closed (N.C.)
47K8 Tip Common
22K8 Ring Common
48K8 Tip Normally Open (N.O.)
23K8 Ring Normally Open (N.O.)
49K8 Tip Normally Closed (N.C.)
24K8 Ring Normally Closed (N.C.)
50No Connection
25No Connection
Table 5 - J1 Relay Contact Pinout
6
CTI Products, Inc.MCN RYB-8 Relay Board Manual
3.3 Relay Input Connections -- J2
The relay input connections appear on a 50-pin female micro-ribbon telco style
connector, J2. The relay input connector is laid out to match the MCN IOB
module pin-for-pin. J2 can be connected to the IOB module directly through a 25pair straight-through male to male cable.
Since the MCN CIB module was originally set up to match the Digitac P805
pinout, the signals are a bit scrambled. For convenience, the pinouts are as shown
in two tables, the first sorted by relay and function, and the second sorted by pin
number. The corresponding signal names for the CIB and IOB modules are also
shown.
Table 7 - Relay Inputs Connector J2 Pinout -- Sorted by Pin Number
8
MCN RYB-8 Relay Board Manual CTI Products, Inc.
4. Mounting and Cabling
The following options are available for the MCN-RYB-8 relay board:
S2-60646Relay Board quad rack-mounting panel
S2-60645Ribbon Cable assembly for CIB or IOB to relay board
(25-pair)
The Mounting Panel mounts in an EIA 19” rack. It can hold 4 MCN RYB-8
boards. It has snap-in standoffs for board mounting and includes tie-points for use
with cable ties. It is 10.5” high (6 Rack Units).
Figure 3 shows a back view of the Mounting Panel with the boards mounted. It
also shows the ribbon cable used to connect the relay boards with an IOB or CIB
module.
6 RACK UNITS
1 RACK UNIT
K1
J2
PRODUCTS, INC.
IN
NETWORK
K2
K4
K6
K8
261
305
MCN-RYB
COPYRIGHT 1996
OUT
K2
K3
K4
K5
K6
K7
K8
J2
261
30535104015452050
84-11194-100
MCN-RYB
10-14-96
COPYRIGHT 1996
PRODUCTS, INC.
NETWORK
IN
OUT
DC IN
NOTE: MOUNTING PLATES SHOWN SEPARATED FOR CLARITY,
PANELS MAY BE MOUNTED ADJACENT.
MODULEGROUP
25
Products, Inc.
J1
1
26
5
30
10
35
15
40
20
45
25
50
TB1
1
++
12V
--
GND
4
ERR
PWR
ACT
ON
123
4
RESET
OPTION
K1
K3
K5
K7
35104015452050
84-11194-100
10-14-96
GROUP
DC IN
K1
PRODUCTS, INC.
IN
K2
K3
K4
K5
K6
K7
K8
J2
261
305
35104015452050
84-11194-100
MCN-RYB
COPYRIGHT 1996
10-14-96
NETWORK
OUT
GROUP
DC IN
J1
1
26
5
30
10
35
15
40
20
45
25
50
TB1
1
++
12V
--
GND
4
25
Products, Inc.
ERR
PWR
ACT
MODULE
1
4
2
3
ON
RESET
OPTION
J1
1
26
5
30
10
35
15
40
20
45
25
50
TB1
1
++
12V
--
GND
4
25
Products, Inc.
ERR
PWR
ACT
MODULE
ON
1234
OPTION
J2
PRODUCTS, INC.
IN
NETWORK
RESET
K1
K2
K3
K4
K5
K6
K7
K8
261
30535104015452050
84-11194-100
MCN-RYB
10-14-96
COPYRIGHT 1996
OUT
MODULEGROUP
DC IN
S2-60435 MCN RACK MOUNT KIT
PWR
ON
OPTION
25
Products, Inc.
ERR
1234
J1
1
26
5
30
10
35
15
40
20
45
25
50
TB1
1
++
12V
--
GND
4
ACT
RESET
QUAD SIZE A
CA-80267-101
Figure 3 Relay Mounting Panel--Rear View
9
68-11206-100
MCN RYB-8 Relay Board Manual CTI Products, Inc.
CABLE TIE HOLE
AMP
CIB OR IOB MODULE
R
VELCRO STRAP
CA-80274-100
Figure 4 Relay Mounting Panel Side
10
MCN RYB-8 Relay Board Manual CTI Products, Inc.
5. Specifications
Relay Circuits8, DPDT (Dual Form C), Sealed
Relay TypeMIL-R-39016/6
Contact TypeGold Plated over Hardened Silver;
Stationary contacts are bifurcated
Contact rating and life
expectancy
Supply Current
(all 8 relays activated)
Operate & Release Time4.0 ms max.
Board Size H x W x D7.5” x 3.75” x 2.5” (mounted with connectors seated)
Relay Control (Input)
Connector
Relay Output (Contact)
Connector)
Optional telephone line
terminations:
Power Connector:4-pin screw terminal strip, accepts #24 to #14 AWG wire.
FuseAGC 1A
PCB Flammability Rating:94V-0
Temperature Rating-25 to +65 Degrees C