CST Berger LM800, LM800GR Instruction Manual

LM800LM800
SeriesSeries
Electronic Self-Leveling Dual-Beam Electronic Self-Leveling Dual-Beam Rotary LaserRotary Laser
LM800
Series
Electronic Self-Leveling Dual-Grade Rotary Laser
LM800 LM800GR
Instruction Manual
Manual de Instrucciones
Manuel d’Instructions
Manuale di Istruzioni Bedienungsanleitung
Instruções de Utilização
2 • LM800 - LM800GR LM800 - LM800GR • 3
LM800
Series
Electronic Self-Leveling Dual-Beam Rotary Laser
LM800 - Fig. 1 LM800GR - Fig. 2
1
3
4
9
7
2
2
1
3
5
LM800
GR
MANUAL GRADE SETTING
5
4
6
6
7
8
G N I T
T E
S E D
A
R G L
A
U N A
GR
M
0
0
8
+
M
L
-
8
Thank you for purchasing the LaserMark LM800 Series Electronic Self-Leveling Rotary Laser Level.
Please read this manual thoroughly before operation
MODELS
LM800 LM800 Electronic Self-Leveling, Dual-Beam, Rotary Laser with Plumb
Down Laser. Dual-Grade when used with Remote Control.
LM800GR Electronic Self-Leveling, Single-Grade Rotary Laser. Dual-Grade when
used with Remote Control.
Copyright © 2005 CST/berger, All rights reserved.
The information contained herein is proprietary information of CST/berger and is subject to change
without notice.
This document shall not be copied or otherwise reproduced without CST’/berger’s written consent.
SAFETY AND CERTIFICATIONS
Working safely with this instrument is possible only when the operating and safety information are read completely and the instructions contained therein are strictly followed.
The use of controls, adjustments, or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
Do not stare into the laser beams. Do not direct the laser beam at other persons. Do not disassemble the instrument or attempt to perform any internal servicing. Laser class is indicated on the instrument.
Repair and servicing of this laser are to be performed only by CST/berger or authorized service centers.
This laser complies with all applicable portions of title 21 of the Code of Federal Regulations set by: the Dept. Of Health, Education, and Welfare; the Food and Drug Administration; the Center for Devices; and the Bureau of Radiological Health.
The instrument has also been tested and complies with the CE certification requirements set forth in the EC regulations 89/336/EEC and EN 61000-6-1 (EN50082-1), EN 61000-6-3 (EN50081-1) and IEC 60-825-1.
4 • LM800 - LM800GR LM800 - LM800GR • 5
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Y
+
+
X
Fig. 9
EN
X—AXIS ERROR
Y—AXIS ERROR
SPINDLE ERROR
LM800 - LM800GR • 7
1 Glass Enclosed 2 Self-Leveling (with ±5º) Rotary Laser
Beam 3 Anti-Drift System LED Indicator 4 Manual Mode LED Indicator 5 Battery Level LED Indicator 6 Remote Sensor eye 7 Top Cage with Gun Sight with “X” &
“Y” Identifiers 8 Heavy-Duty Handle – Built-in Trivet
(LM800 only) for Laydown and
Vertical Jobs with 5/8- 11 Tripod
Threads
9 Down Plumb Beam (LM800 only)
6 • LM800 - LM800GR
APPLICATIONS
Use your LM800 Series Self-Leveling Laser for many projects including:
Outdoor General Construction Applications & Site Preparation, Grading & Excavating, Batterboards and Foundations, Masonry Work, Setting Concrete Forms, Machinery Installation, Marking Elevation, Septic Work, Paving Roads, Driveways, Checking Depth of Trenches.
Drop Ceiling Installation, Floors, Cabinets & Shelves, Carpentry, Pools, Decks & Patios, Flagpoles, Aligning 90° Joints & Edges, Landscaping, Tile Work, Septic Work, Plumbing, Batterboards, Fencing, Walls & Partitions, Remodeling, Siding Installation, Doors & Windows.
Operating Instructions for General Construction Applications
Note: A level plane of laser light is created by the rotating beam of the laser. The laser light can be used to reference elevations with the use of a laser detector.
1. Place the instrument on a flat, level surface such as a tripod. Setup the instrument in an area where it can not be obstructed and is set at a convenient height.
2. Press the “A” button. Allow the instrument to self-level.
3. Setup a "Benchmark".
Note: Setup a Benchmark During the work day, periodically check your initial set-up to ensure that the laser reference has
not moved. Establish, at a suitable distance (furthest possible), a benchmark (reference) on a stable surface
(ie. tree, building). Periodically during the work day, check the benchmark to ensure that your setup has not moved.
Power Button (Allow 60 seconds for instrument to self­level)
For LM800 – Use also to activate the Plumb Down Beam
ADS Button– Anti-Drift System ON | OFF
Manual Mode/Automatic Level
Button
Variable Rotation Button– 4 Speed Selections (LM800 Only)
Sweep Button– 4 Preset Scanning/ Angles and spot. (LM800 Only)
CW and CCW Button Clockwise andCounter- Clock­wise Head Positioning (Press and Hold Button Moves the Rotation More Quickly
For LM800– Use also during Grade Mode.
Manual Grade Adjustment Buttons (LM800 GR Only)
ICONS
Reference in the text
AA
BB
CC
DD
EE
FF
GG
HH
II
FEATURES - Fig. 1 & 2
LM800 - LM800GR • 98 • LM800 - LM800GR
Plumbing / Lay-Down (LM800 Only)
1. On a flat surface, place the instrument on its back using the built-in trivet (control
panel facing upward).
2. Press the “A” button once, and allow time for the instrument to self-level.
Variable Rotation Mode (LM800 Only)
The rotation mode will give you the option of increasing or decreasing the speed of the rotating laser. This feature can be used to create a room-wide, 360° height reference or vertical plumb line for general alignment, drop ceiling installation, and more. Pressing the “D” button, will adjust the speed from 600, 300, 150, and 0 RPM.
Sweep or Scanning Mode (LM800 Only)
Instead of creating a room-wide reference line, the Sweep (Scanning) Mode creates a shorter, brighter laser “chalk line” that can be used for leveling or plumbing doors, windows, fixtures, and more. You may also use this feature to keep the instrument from interfering with other lasers and detectors on site. Pressing the “E” button, will lengthen or shorten the sweep of the laser beam. Preset angles of 0º, 10º, 45º, 90º, and 180º can be set. Position the sweep area by using the “F” and “G” buttons.
Re-Leveling
If bumped or moved, the instrument will automatically attempt to re-level itself. On a job site, it may be necessary to prevent re-leveling in order to prevent inaccurate measurements by the operator. The Anti-Drift System (ADS) is used for this purpose (see Anti-Drift System - ADS). The instrument can also be placed in Manual Mode to allow the instrument to continue operating when out of level ( see Manual Mode ).
Axis Drive Error
If the laser is set up or tipped beyond its self-leveling range of ±5°, the laser head will initially attempt to level; however, when the self-leveling limit is reached, an error will indicate an axis error (Fig. 6). Turn the instrument OFF, move the instrument to a more level position, then turn the instrument on again.
Spindle Motor Error
If the laser spindle motor fails to rotate or rotates outside of the set speed, an error indicator will indicate a spindle motor error (Fig. 6). If this occurs, see Troubleshooting.
4. Set the Variable Rotation Mode to the desired rotation speed of the laser head. Ideal speed for use with laser detector is 600 RPM. (LM800GR: the rotation speed is fixed at 600 RPM)
5. Take elevation readings using the plane of laser light as a reference (Fig. 3). Follow the Detector Operation Procedures in this manual.
Ceiling Grid Applications
1. Attach the laser to the optional wallmount bracket. Be sure the control buttons are facing outward. Tightening the locking screw will secure the instrument to the bracket.
2. After installing the first piece of ceiling trim, attach the wallmount to it. Be sure the wallmount is secure to the trim.
3. Press the “A” button. Allow the instrument to self-level.
4. Adjust the distance of the instrument from the grid, typically 1.5-inch (38mm) below the grid. Loosen the adjustment screw and slide the instrument up/down on the wall mount. When the desired height has been reached, tighten the adjustment screw to secure the instrument.
5. Setup a "Benchmark".
6. Install the ceiling grid. Attach the magnetic laser target to the ceiling trim being installed. Adjust the height of the trim until the laser beam strikes the target (Fig. 4).
Laydown Applications (LM800 Only) - (Fig. 5)
1. Place the instrument in the laydown position on a flat, level surface.
2. Press the “A” button. Allow the instrument to self-level.
3. Setup a "Benchmark"
OPERATIONS
Remove the laser from its carrying case.
Note:
Instruments are shipped with ADS on as the default setting. This setting can be changed by
the user (see Anti-Drift System - ADS )
Leveling
1. The instrument can stand alone on a level, sturdy surface or preferably secured to a 5⁄8" -11 surveyor’s tripod.
2. Press the “A” button once, and allow time (up to 60 seconds) for the instrument to self-level. Note: The laser head may begin to rotate before leveling is complete. The self-leveling
speed is approximately 1° per 4 seconds.
3. After self-leveling, the instrument will begin operating in Rotation Mode for LM800-GR, last select mode of operation (i.e. Sweep, Spot, Rotation Mode) for LM800.
LM800 - LM800GR • 1110 • LM800 - LM800GR
Grade Mode –Dual Axis Grade
The LM800 Series can also be used for Dual Axis Grade using the remote control (57-RC700).Fig. 8
The MODE button on the remote control when pressed will put the instrument in Manual Mode, if ADS is not selected. Once in Manual Mode, the UP ("MORE") and DOWN ("LESS") arrow buttons on the remote control adjusts the rotating head on the Y axis to the desired grade. The LEFT("MORE") and RIGHT("LESS") arrow buttons on the remote control, adjusts the rotating head on the X axis to the desired grade (Fig. 9).
Line Position Mode (LM800 Only) - Fig. 10
In this mode, the instrument allows you to fine-tune the location of your vertical (plumb) laser line. For example, if you’ve established a plumb line and find that the line is slightly off to the left or right
of your target, use Line Position to jog the line into place without moving the entire instrument (useful for floor and wall tile installation, walls or partitions, etc.). The laser will now remain aligned to your target even if you enter other modes (Rotation, Spot, Sweep.)
Line Position mode is activated when the instrument is placed in the plumbing position (control panel facing upward). While the instrument is in the pluming position, it can be used in Rotation, Sweep, or Spot mode. To enter the Line Position mode and position the laser reference point, the instrument must be rotating. Use the “F”and “G”buttons to position the laser reference point while the instrument is rotating. If the instrument is in Spot mode or Sweep mode the “F” and “G” buttons are used to move the spot or sweep.
NOTE: The LEFT and RIGHT Arrow buttons on the 57-RC700 Remote can be used to position the laser reference point in any mode of operation. If the instrument is in Manual Mode, the Up and Down Arrow buttons can also be used to position the laser reference point up and down.
Plumb Down Beam/Powering Off (LM800 Only)
The “A” button is a dual purpose button. This button is used to power the instrument on/off and to turn on the plumb down beam. While the instrument is off, press the “A” button momentarily, turning the instrument ON. Momentarily pressing the “A” button again, after the instrument is ON, will toggle the plumb down beam on/off. To turn the instrument off, press and hold the “A” button . The Manual and ADS LEDs will alternately flash to indicate that the “A” button can be released (approx. 3 seconds).
Anti-Drift System – ADS
The Anti-Drift System, when ON, will signal to the operator that the instrument has been moved out of level. When the instrument has been moved out of level, The laser head will stop rotating and the beam and ADS LED will blink.
The default setting for ADS is user selectable. The default setting may be set to ADS ON or ADS OFF. When the instrument is OFF, press and hold the “I” button (LM800-GR) or the “G” button (LM800) and then press the “A” button. Once the instrument is on, turn the instrument off for 15 Sec and then back on. If ADS was ON (OFF), it will now be OFF (ON).
When the LM800 series is first turned on, the ADS feature does not begin recording for one minute. This allows the instrument to be set up and adjusted.
To activate ADS, Turn off the Manual Mode (if it is on) and then press the “B” button. If after 1 minute, the instrument is disturbed and the ADS LED is flashing it is necessary to check any bench marks that have been made and ensure the proper "HI" (Height of Instrument). Reset ADS, by pressing the button one time, you will have an additional minute to set and check your measurements.
To turn ADS off press the “B” button once. This will put the instrument into normal Auto Self­Leveling mode.
Manual Mode
Manual mode disengages the leveling feature; allowing the instrument to be placed in any position (to grade). To activate the Manual Mode, Turn off the ADS (if it is on) and then press the “C” button. (Note: The instrument should be level before entering manual mode to eliminate the possibility of error.) Once the button has been pressed the MANUAL light will blink. Press the “C” button again to return to normal operation.
Note: When returning to normal operation the instrument must be within its leveling range. Re-set the instrument to a level position before pressing the “C” button to the off position.
Grade Mode –Single Axis Grade
The single grade function is ideal for general site grading, checking excavations, landscaping and drainage, and more.
The selected grade can be as much as a positive or negative 10%, and set in reference to the Y axis of the instrument (Fig. 7), noted by the raised printing on the sides of the top cage of the instrument.
The laser will react to “MORE” and “LESS” input. Allow the instrument ample time to react to the input provided, between grade setups or changes.
Note: LM800 will respond to “MORE” and “LESS” only in ROTATE mode, when using control panel.
NOTE: The total percent grade possible is from a perfectly level base position. If the instrument is mounted on a tripod head which is not perfectly level, the grade percentage range capability will be reduced by the slope of the base, as this affects the tilt range of the laser head. For maximum grade range, ensure a level tripod head using a spirit level before mounting your instrument.
LM800 - LM800GR • 1312 • LM800 - LM800GR
Upright Position Calibration – X axis
Keep the instrument in its current position. Power OFF the instrument.
1. Power On the instrument while holding the “C” button down, then release the “A” button. You will know if Calibration Mode is activated when the
MMAANNUUAALL
and
AADDSS LLEEDD
s flash alternately.
2. The “C” and “B” buttons change the x-axis increments. The “C” button will produce a positive (+) increment.
3. The “F” and “G” buttons change the y-axis increments. The “F” button will produce a positive (+) increment. In the LM800GR the “H” and “I” Arrow buttons change the y-axis increments. The “H” Arrow will produce a (+) increment.
4. You must raise or lower the beam to center between Position A and B on the target (Fig. 12). The instrument will react to “+” and “–” input within the X+ quadrant. The instrument DOES NOT react to adjustments until the instrument is forced to re-level (ie. rotate and re-check Position “A”.
If Position B is below Position A, increase the increment (+). If Position B is above Position A, decrease the increment (-).
5. Turn the instrument OFF. The adjustments are automatically saved.
You must now repeat the peg test to insure you have made the correct calibration. A peg test can be done in Calibration Mode with a detector.
Upright Position Peg Test and Calibration – Y axis
To test the Y axis, mount the instrument on a tripod and place approximately 100 feet (30m) away from the target, with the control side (Y– quadrant) facing the target; follow steps 2 thru 4 of "Upright Position Peg Test – X axis". Calibrate as in "Upright Position Calibration – X axis", choosing the Y axis to calibrate and adjusting “+” and “–” input as necessary within the Y+ quadrant (Fig.
13).
If you are unable to calibrate the instrument, or if the difference between points A and B is too great to calibrate, please contact CST/berger or an authorized service center for assistance.
Laydown Position Peg Test – Z axis (LM800 Only)
1. To test the Z axis, place the instrument on its back using the built-in trivet (control panel facing upward), 100 feet (30m) from a wall on a flat, level surface (Fig. 14).
2. Hang a plumb line down the wall at least 8 feet (2.5 m) long.
3. Press the “A” button and allow the instrument to self-level. If necessary, adjust the rotation speed to easily view the laser beam on the wall. Orient the instrument parallel to the wall and attempt to align with your plumb line.
If the laser line does not align with the plumb line, then calibration is necessary.
BATTERY REPLACEMENT
The battery indicator LED indicates the battery voltage level.
Green Fully Charged battery Red Battery is Low, but will operate. Flashing Red Battery is TOO Low for instrument to properly operate and battery should
be replaced/recharged immediately.
Rechargeable Battery Pack
The rechargeable battery pack (57-NB1000) will begin to perform optimally after five full charges and discharges.
To charge the battery pack, ensure the power is off, and connect the charging plug to the battery pack charge port. (1 - Fig. 11) Then plug the charger into the appropriate 110/230V AC outlet. Charge time is typically around 8 hours depending on the discharge state of the battery pack. The instrument can be charged and used at the same time, but the charge time will be extended.
CALIBRATION
Your LM800 Series Self-Leveling Laser is a sealed instrument and is calibrated to precise accuracies at the factory. However, a calibration check is recommended before the initial use of your laser, and then periodically from that point forward. Be sure to allow time (up to 60 seconds) for the instrument to completely self-level before each check.
Upright Position Peg Test – X axis
1. To test the X axis, mount the laser on a tripod or a level, sturdy surface and place approximately 100 feet (30m) away from a wall. Face the right side of the instrument to the wall (Fig. 12).
2. Press the “A” button and allow the instrument to self-level. Using the laser detector, locate and mark the position of the laser line on the
wall Position “A”).
3. Loosen the instrument from the tripod and rotate the instrument 180°. Ensure that the height of the tripod does not change, as this will affect your results. Secure and re-level the instrument.
4. Again, using the laser detector, locate and mark the position of the laser on the wall (Position “B”).
5. Mark the centerline between Position A and Position B (Position “C”). Callibration is necessary if the vertical difference between Position A and Position C or Position B and Position C is greater than the specified accuracy.
LM800 - LM800GR • 1514 • LM800 - LM800GR
Vertical Leveling No Yes Grade Capability with Control Panel– Single Axis (Up to ±10%)
with Remote– Dual Axis (Up to ±10%)
Self-Leveling Range ±5° ±5° Battery Power 15± Hours Continuous Use with Fully Charged
Ni-Cad Battery Pack (variable w/ temp./usage)
Rotation Speed Fixed Variable (0,150, 300, 600) Weight 5.5 ±lbs (2.5kg) with Battery Visible Split Beam No Yes Plumb Down Beam No Yes, using the POWER button Scanning Feature No Yes Operating temperature 22°F to 120°F (-6°C to 49°C)
Environment IP67 – Waterproof
TROUBLESHOOTING
The following information lists basic tests that can be performed to check the LM800 Series in the event of poor performance.
Rechargeable Battery Pack: For maximum battery life, the battery pack must contain a full charge. The batteries will begin to perform optimally after five full charges and discharges.
Instrument does not rotate or self-level, or produces “Error” message: Ensure that the instrument is within its self-leveling range. Reset the internal processor by turning power OFF, wait 15 seconds, and power the instrument ON again. If the instrument rotates but does not self-level, be sure that MANUAL mode is not selected.
If troubleshooting is not effective, please contact CST/berger or an authorized service center for assistance.
WARRANTY
Two Year Warranty. CST/berger, a division of Stanley Works, warrants the LM800 against defects in material and workmanship for a period of two years from the date of purchase. Deficient products will be repaired or replaced at CST/berger's discretion.
For warranty and repair information, contact your local distributor.
For U.S.: Before returning the instrument to CST/berger, call (815) 432-9200 for a Return Authorization Number from our Customer Service Department.
Laydown Position Calibration – Z axis (LM800 Only)
Keep the instrument in its current position. Power OFF the instrument.
1. Power ON (”A” button) the instrument while holding the “C” button down, then release the “A” button. You will know if Calibration Mode is activated when the
MMAANNUUAALL
and
AADDSS LLEEDD
s
flash alternately.
2. The “C” and “B” button change the axis increments. The “C” button will produce a positive (+) increment.
3. Select the “C” button to position the rotating beam counterclockwise, or the “B” button to position the rotating beam clockwise into alignment with your hanging plumb line. For example, the rotating beam must be positioned counterclockwise to align with the plumb line, so you must select the “C” button (See Figure 14).
4. Turn the instrument OFF. The adjustments are automatically saved.
You must now repeat the peg test to insure you have made the correct calibration. A peg test can be done in Calibration Mode.
MAINTENANCE AND CARE
Always clean the instrument after use. Use a soft, dry cloth to remove any dirt or moisture from the instrument. Do not use benzene, paint thinner, or other solvents to clean the instrument. Store the instrument in its case when not in use. Batteries should be removed before long-term storage.
ENVIRONMENTAL PROTECTION
Recycle raw materials instead of disposing as waste. The machine, accessories and packaging should be sorted for environmental-friendly recycling. Do not throw used batteries into waste, fire or water but dispose of in an environmentally friendly manner according to the applicable legal regulations.
SPECIFICATIONS
Description LM800GR LM800
Operating Range Up to 2000’ (610m) diameter with laser detector Class & Diode Power 2M - 650 nm 2M - 635 nm High Power Leveling Accuracy ±1/16-in @100’ 1/16”@100’
(+/-1.5 mm @ 30m) (+/-1,5 mm@30m)
Vertical Accuracy N/A 1/8”@100’(6,4 mm@30m) Leveling Type Electronic Self-Leveling
Horizontal Leveling Yes Yes
LM800 - LM800GR • 1716 • LM800 - LM800GR
Features (Fig. 16)
1 LCD readout window 5. Beam Resolution 2 Speaker 6. Volume ON | OFF 3 Beam Capture Window 7. LCD Readout Window (LD-400 and LD-120 only) 4 Power ON/OFF 8. Battery Door
Power
A 9-volt battery will provide up to 3 months of typical usage. When the instrument is turned on and the low battery symbol remains lit, the battery should be replaced.
Operation– Laser Detector
1. Mount the instrument onto a sighting rod if you are using one. Turn on the instrument by pressing the ON/OFF pad. The LCD symbols will momentarily flash and the “coarse” beam indicator symbol will remain lit and the audio signal will be on (Fig. 17).
2. Expose the beam capture window of the laser detector towards the direction of the rotating laser.
3. Slowly move the laser detector in an upward and downward direction until the LCD beam indicator arrows appear and/or a pulsing audio signal is heard. Use the Beam Resolution feature to choose between the coarse/low setting, used for approximating level or for initial locating of the center level point, the medium setting, used for greater accuracy, and the fine/high setting, used for the most accurate pinpointing of level. (to see the available Resolutions, please refer to the Specs Table).
4. Move the detector upward when the low beam indicator light is lit (with volume on, a short pulsing audio tone is heard). Move the detector downward when the high beam indicator arrow is lit (with volume on, a long pulsing audio tone is heard). When the beam is level, the level beam indicator line will be lit and a solid audio tone will be heard.
If the detector is not struck by a laser beam after 5-8 minutes, the detector will automatically shut itself off to preserve battery life. Turn the instrument back on using the power button.
Special Features– Laser Detector
The LCD display of the detector LD-400 has seven distinct channels of information, indicating the position of the detector in the plane of laser light, as indicated in Fig. 18 (the detectors LD-120 and LD-100N have three).
As you move the detector closer to the center, the arrows fill in to indicate the laser position. The detector has a unique memory feature, which preserves the last position of the laser beam if
the detector is moved out of the plane of laser light, as well as built in electronic filtering for bright sunlight and electromagnetic interference.
The detector LD-400 has three speaker selections (Off, Loud (105dBA) and Louder (125+ dBA)), whereas the models LD-120 and LD-100N have only two (Off and On).
CST/berger's liability under this warranty is limited to repair or replacement of the instrument. Any attempt to repair the product by other thanfactory authorized personnel will void this warranty. Calibration, batteries and maintenance are the responsibility of the user. Where permitted by law, CST/berger is not responsible for incidental or consequential damages.
Agents of CST/berger cannot change this warranty. CST/berger is not responsible for damage resulting from wear, abuse, or alteration of this product. The user is expected to follow ALL operating instructions.
This warranty may provide you with additional rights that vary by state, province or nation. LASERMARK is a registered trademark of CST/berger.
IMPORTANT NOTE: The customer is responsible for the correct use and care of the instrument. Moreover he is completely responsible for checking the job along its prosecution, and therefore for the calibration of the instrument. Calibration and care are not covered by warranty.
Subject to change without notice
57-RC700 REMOTE CONTROL - (Fig. 15)
The remote control can be used up to a maximum of 100 feet (30 m) away from the instrument. The remote must be pointed towards the instrument for proper operation. Requires 2 ‘AA’ Alkaline batteries.
(1) Variable Rotation adjusts to preset rotation speeds–LM800 Only (2) Line Positioning (only in lay-down position) – LM800 Only
X-Axis Grade Adjustment– LM800/LM800GR (3) CCW- positions the laser in sweep or spot mode -- LM800 Only (4) N/A– (5) Y-Axis Grade Adjustment LM800/LM800GR (6) Scan/Sweep Mode- adjusts to preset sweep angles– LM800 Only (7) CW-positions the laser in sweep or spot mode -- LM800 Only
(8) Manual Mode– Places instrument in manual grade if ADS is not selected.
UNIVERSAL LASER DETECTOR
Introduction
The LaserMark® Universal Laser Detector aids in locating and targeting a visible or invisible beam emitted by a rotary laser; perfect for use in outdoor conditions, where sunlight and distance may make locating the beam more difficult. The laser detector includes a rod clamp which allows to mount the detector onto square, round or oval sighting rods.
LM800 - LM800GR • 1918 • LM800 - LM800GR
Gracias por su confianza en nuestros niveles láser LaserMark LM800. Se recomienda leer atentamente estas instrucciones de uso, antes de la primera
utilización del láser.
MODELOS
57-LM800 LaserMark Láser autonivelante electrónico Horizontal / Vertical, Doble
Plomada arriba y abajo. Doble Inclinación manual en posiciones horizon tal y vertical, utilizando el mando a distancia
57-LM800GR LaserMark Láser autonivelante electrónico Horizontal con Inclinación
manual. Doble Inclinación manual, uilizando el mando a distancia
Copyright© 2005 CS/berger. Derechos reservados.
Toda esta información es propiedad de CST/berger. Este documento no debe ser copiado o reproducido sin el consentimiento escrito de CST/berger.
SEGURIDAD Y ESPECIFICACIONES
Es posible trabajar con el aparato sin peligro, sólo después de haber leído atentamente las instrucciones para el uso y las advertencias de seguridad, y siguiendo estrictamente las instrucciones.
El uso de instrumentos ópticos, controles, ajustes o procedimientos de funcionamiento distintos a los especificados en el presente manual pueden provocar una exposición a radiación peligrosa. La clase del láser está indicada en la etiqueta.
No mirar hacia el rayo. No apuntar el rayo láser hacia otras personas. No desmontar el instrumento, ni intentar hacer ninguna reparación. La reparación y el mantenimiento de este láser deben ser realizados solamente por CST/berger o centros de servicio autorizados.
El equipo cumple con todas las especificaciones del artículo 21 del Código de Regulación Federal (U.S.A.) el Departamento de Sanidad, Educación, Alimentación y del Centro para la Salud Radiológica.
El láser también cumple con las especificaciones CE según las normas 89/336/EEC, EN 61000-6-1 (EN50082-1), EN 61000-6-3 (EN50081-1) y IEC 60-825-1.
Care of Your Universal Laser Detector
This instrument is gasket sealed for water and dust protection. Use a soft, dry cloth to remove any dirt or moisture from the instrument before storage. Do not use benzene, paint thinner, or other solvents to clean the instrument. Remove battery before long-term storage of the instrument.
Specifications
* Note: Sensitivity values based on standard conditions with most lasers; may vary slightly due to make, manufacturer, beam size, or working conditions.
Subject to change without notice
DDeessccrriippttiioonn LLDD--440000 LLDD--112200 LLDD--110000NN
Dimensions 6.6” H x 3“ W x 1” D (169mm x 76mm x 25mm)
Weight 10 oz. (275g)
Range Up to 2000-ft (610m) Diameter
Beam Resolution *
Fine ±0.75mm Medium ±1.5mm Wide ±3mm
Medium ±1.5 mm Wide ±3 mm
Medium ±1.5mm Wide ±3mm
Readout LCD, 2 windows LCD, 2 windows LCD, 1 window
Power One 9-volt battery provides 3 months of typical usage
Warranty 1 year (For warranty conditions see “Warranty”)
E
LM800 - LM800GR • 2120 • LM800 - LM800GR
APLICACIONES
Utilice su nivel láser de Nivelación Automática para estos y muchos otros proyectos: NIVELACIONES EN INTERIORES: Instalación de falsos techos, armarios, mostradores, ventanas. NIVELACIONES EN EXTERIORES: Porches, cubiertas, cercados, postes, jardines,
inclinaciones, cementos.
Instrucciones de manejo en aplicaciones generales
Nota: El rayo láser giratorio crea un plano de luz a nivel. Esta luz láser puede utilizarse junto con un receptor láser como referencia de elevaciones.
1. Coloque la unidad en una superficie llana y nivelada (por ejemplo, un trípode). Instale la unidad en una zona libre de obstáculos al paso del láser y situada a una altura adecuada.
2. Pulse el botón de encendido. Deje que la unidad se nivele automáticamente.
3. Fije una marca de referencia.
4. Fije el modo de rotación variable a la velocidad a la que quiera que gire el cabezal del láser. La velocidad ideal para el uso con receptor láser es de 600 r.p.m. (El láser LM800GR tiene una velocidad de rotación fija de 600 r.p.m.)
5. Tome las medidas de elevación tomando como referencia el plano de luz láser (Fig. 3). Siga las instrucciones para el manejo del receptor que aparecen en este manual.
1 Cabeza protegida mediante
urna de cristal
2 Cabeza rotatoria, campo de
autonivelación” de +/- 5°
3 Indicación alarma
antimovimiento (ADS) 4 Indicación Funcion Manual 5 Indicación LED de carga de
las pilas
6 Tres receptores del mando
a distancia 7 Punto de mira con
indicaciones de los ejes “X”
y “Y” 8 Asa de transporte / Rosca
5/8” x 11 para colocar
verticalmente el láser en
trípode 9 Salida de la plomada hacia
abajo (sólo LM800)/ Rosca
5/8” x 11 estandard
IInntteerrrruuppttoorr OONN//OOFFFF
(conexión / desconexión) – 60 segundos para que el láser se autonivele.
(Sólo para LM800 – Una segunda pulsación apaga la plomada de abajo / para apagado total mantener pulsado el interruptor unos dos segundos)
IInntteerrrruuppttoorr
sistema de alarma
antimovimiento
((AADDSS))
IInntteerrrruuppttoorr ffuunncciióónn mmaannuuaall
IInntteerrrruuppttoorr ddee aajjuussttee ddee llaa vveelloocciiddaadd
de la cabeza. Cuatro velocidades (LM800GR – sólo una velocidad)
IInntteerrrruuppttoorr
ddee bbaarrrriiddoo
. 4 ángulos
fijos y punto fijo (Sólo LM800) IInntteerrrruuppttoorreess ddiirreecccciioonnaalleess ddee llaa
ccaabbeezzaa
. Rotación en ambos sentidos. Manteniendo presionado los botones se aumenta la velocidad de rotación de la cabeza
(LM800 – Utilizar también en el Modo Inclinación Manual)
IInntteerrrruuppttoorreess ppaarraa aajjuussttaarr llaass iinncclliinnaacciioonneess
manuales (sólo
LM800GR)
DESCRIPCIÓN DEL PANEL DE CONTROL
Referencia nel texto
CARACTERISTICAS Fig. 1 & 2
AA
BB
CC
DD
FF
EE
HH
GG
II
ESTABLECER UNA REFERENCIA Durante el día de trabajo, compruebe periódicamente la configuración inicial para asegurarse de
que la referencia del láser no se ha movido. Establezca una marca de referencia en una superficie fija, como un árbol o un edificio, a una distancia adecuada (lo más lejos posible). Compruebe periódicamente la
marca de referencia a lo largo del día para asegurarse de que la configuración no ha variado.
Rotación vertical (LM800)
1. Coloque la unidad en posición “tumbada” sobre una superficie nivelada lisa utilizando la asa, con el panel de control hacia arriba.
2. Presionar el interruptor “A” una vez, y dejar aprox. 60 segundos al láser para que se ponga a nivel. Para un ajuste fino de la línea vertical o de la plomada, ver “Función Posición Línea”.
Rotación de la cabeza (LM800)
Con este “Funcion Rotación” se puede aumentar o disminuir la velocidad de rotación de la cabeza.
Presionando varias veces el interruptor “D”, se consigue una velocidad de 600, 300, 150 o 0 RPS.
Funcion “barrido” (LM800)
El funcion “barrido” del láser LM800 crea una línea láser muy visible, que puede ser dirigida girando la cabeza rotatoria. Esto es particularmente útil cuando hay que delimitar el área del rayo láser para evitar interferencias con otros láser o receptores en la obra. Además con esta función se aumenta de una manera considerable la visibilidad del rayo láser. Se puede utilizar esta función en horizontal y en vertical.
Presionando el interruptor “E” se elige entre ángulos fijos de 0°, 10°, 45°, 90° y 180º. Con los interruptores “F” y “G” se dirige la cabeza rotatoria
Auto-nivelación
En caso de que el instrumento sea golpeado o desnivelado, el instrumento intenta auto-nivelarse automáticamente. En la obra, más vale evitar que el láser vuelva a auto-nivelarse, para evitar medidas imprecisas; para eso se utiliza la Función alarma antimovimiento (ADS).
Es también posible seleccionar la Función Manual para permitir que el láser siga trabajando cuando esté fuera de nivel (ver “Función Manual”).
Error “fuera de nivelación”
En caso que el láser sea golpeado más allá de su “campo de autonivelación” de +/- 5°, el láser intenta autonivelarse, pero cuando ha llegado a su límite, una indicación evidenciará un error (Fig.
6). Apagar el láser, ponerlo en una posición más nivelada, luego encenderlo de nuevo.
Error “Spindle Motor”
Si con el motor en funcionamiento la cabeza no gira, se produce un error de Spindle indicado mediante el encendido intermitiente de los dos LED rojos (Fig. 6). Dirigirse a la sección “Solución de Problemas”.
LM800 - LM800GR • 2322 • LM800 - LM800GR
Uso en falsos techos con rejilla
1. Monte el láser en el soporte de pared (opcional). Asegúrese de que los botones de control queden mirando hacia afuera. La unidad se afianza al soporte apretando el tornillo de sujeción.
2. Después de instalar el primer puntal en el techo, fíjele el soporte de pared. Asegúrese de que el soporte de pared está firmemente sujeto al puntal.
3. Pulse el botón de encendido “A”. Deje que la unidad se nivele automáticamente.
4. Ajuste la distancia del aparato a la rejilla (normalmente unos 38 mm por debajo de ésta). Afloje el tornillo de ajuste y deslice la unidad hacia arriba o abajo a lo largo del soporte de pared. Cuando logre la altura deseada, apriete el tornillo de ajuste para afianzar la unidad.
5. Fije una marca de referencia.
6. Instale el enrejado en el techo. Instale el objetivo magnético del láser al puntal del techo que va a montar. Ajuste la altura del puntal hasta que el rayo láser alcance el objetivo magnético (Fig. 4).
Aplicaciones en superficie (sólo LM800) – (Fig. 5)
1. Coloque la unidad en una superficie plana y equilibrada.
2. Pulse el botón de encendido. Deje que la unidad se nivele automáticamente.
3. Fije una marca de referencia.
FUNCIONAMIENTO
Sacar el láser del maletín. Nota: TODOS LOS INSTRUMENTOS VIENEN DE FÁBRICA CON LA FUNCIÓN ADS POR DEFECTO.
No obstante el usuario puede variarlo (ver “Sistema Alarma Antimovimiento – ADS”).
Nivelación
1. El láser se puede colocar sobre cualquier superficie lisa o montarlo en un trípode estándar con rosca de 5/8” x 11.
2. Presionar el interruptor “A” una vez, y dejar aprox. 60 segundos al láser para que se autonivele. Nota: La cabeza puede empezar a girar antes que el láser se ha nivelado. La velocidad de nivelación es de aprox. 1° cada 4 segundos.
3. Cuando el láser esté nivelado, empieza a funcionar en “modo rotación” en el modelo LM800­GR; en el último modo seleccionado antes de apagarlo (por ej. Barrido, Punto Fijo, Rotación) en el modelo LM800.
Nota: El LM800 reaccionará al cambio de grados sólo en Función Rotación, cuando se utilize los botones del panel de la unidad. Con el mando a distancia se pueden cambiar los grados indipendientemente de la función (PUNTO, BARRIDO, ROTACION).
Utilizando el mando a distanzia 57-RC700, se puede realizar la doble inclinación (Fig. 8), mediante la desconexión del ADS, pulsación de la tecla “Función Manual”, y la utilización de los cuatro botones indicados con el símbolo “punta flecha”.
Las dos flechas arriba y abajo inclinan el plano Y y las flechas derecha e izquierda inclinan el plano X (Fig. 9).
Función posición línea (LM800) – Fig. 10
En esta función, la unidad permite ajustar la posición del plano vertical (plomada). Por ejemplo, si ha establecido una orientación y se da cuenta que está desviada hacia la derecha
o izquierda del objetivo, use la función “Posición de la Línea” para colocar la línea en su lugar sin tener que mover la unidad (útil para la instalación de paredes y tabiqueria, ecc.). El láser se mantendrá alineado, incluso al cambiar a otras funciones (rotación, punto, punto-a-punto).
Posición de línea será activado únicamente si la unidad es situada en posición de nivelación vertical (panel de control hacia arriba). En esta posición el láser puede trabajar en funcion Rotación, Barrido, o Punto. Para activar la Función Posición Línea y orientar la línea, el láser tiene que estar en Rotación. Use los botones “F” y “G”, para ajustar la posición del punto de referencia laser. Cuando el láser esté en función Punto o Barrido, presionando estos botones “F” y “G”, se mueve el punto láser en el sentido contrario a las agujas del reloj o en el sentido de las agujas del reloj, así como si el láser estuviera en nivelación horizontal.
Nota: Con el mando a distancia 57-RC700 utilizar el botón izquierdo o el botón derecho para orientar la posición del plano láser, independientemente que el láser esté en Función Rotación, Punto o Barrido.
Se puede analogamente orientar el plano vertical utilizando como referencia el punto laser horizontal (emitido desde la parte superior de la unidad); el plano vertical se moverá manteniendo un ángulo de 90º con el punto.
NOTA: En Función Manual, se pueden también utilizar los otros dos botones “punta flecha” para inclinar el plano vertical.
LM800 - LM800GR • 25
Sistema de alarma antimovimiento - ADS –
Esta función avisa al usuario cuando el láser puede variar la cota de trabajo. Con esta función conectada, cuando la cota del instrumento varíe porqué por ej. el trípode se ha movido, la cabeza detiene su rotación, y la indicación ADS y la señala láser parpadean. Esta función puede ser activada tanto en la rotación horizontal como en la rotación vertical (LM800).
El usuario puede ajustar por defecto en ON o OFF. Con la unidad apagada, mantener pulsado el botón “I” (LM800GR) o “G” (LM800), y después apretar el botón “A”. Cuando la unidad está encendida, apagarla durante 15 segundos y encenderla otra vez.
Si la función ADS estaba ajustada por defecto en ON (OFF), estará ahora en OFF (ON). Cuando se activa la función ADS, hay que esperar 1 minuto para que esta función sea realmente
activa. Eso permite el ajuste del láser. Para activar la función ADS, desconectar la Función Manual, si está conectado, presionando “C”,
y depués presionar “B”. Después de un minuto, si el láser está golpeado y la indicación ADS parpadea, el usuario tiene que
dirigirse al láser, controlar que ha pasado y luego nivelarlo, presionando el interruptor ADS (“B”); ahora tiene otro minuto para ajustar el láser. Presionando el interruptor “B” otra vez se desconecta la función ADS y el láser vuelve a auto-nivelarse normalmente.
Función manual
La función manual desconecta la autonivelación del láser; así se puede colocar el instrumento en todas las posiciones.
Para activar la función manual, apague el ADS (si está conectado), luego presione el interruptor “C”. (Nota: Se aconseja esperar que el láser esté nivelado y la cabeza gire, antes de activar el funcion manual, así se elimina la posibilidad de error). Después el indicador de “Función Manual” parpadeará. Presione otra vez el interruptor “C” para volver a trabajar en funcion autonivelante.
Nota: Cuando se vuelva a trabajar en función autonivelante, el láser tiene que estar posicionado dentro de su campo de autonivelación; antes de presionar este interruptor, asegúrese que el láser esté bastante nivelado.
Ajuste de las Inclinaciones - Inclinación manual individual
Esta función es ideal para hacer en general inclinaciones en una obra, controlar excavaciones, drenaje etc.
La inclinación seleccionada puede ser tanto positiva como negativa en un 10% máximo, y ajustar una referencia al eje Y de la unidad (Fig. 7).
Dar tiempo a la unidad para reaccionar entre cambios de grados.
24 • LM800 - LM800GR
Nota: Se puede obtener el 10% sólo cuando el láser está sobre una base perfectamente nivelada. Si por ejemplo el trípode no está perfectamente nivelado, el porcentaje de inclinación posible será disminuido de la inclinación de la cabeza del trípode, pues esta influye en el campo de movimiento de la cabeza del láser.
Calibración del error horizontal– Eje X
No mueva el instrumento de su posición actual. Apague la unidad.
1. Encienda el láser mientras tiene presionado el interruptor “C”; luego soltar el botón “A”. El láser está ahora en el función “calibración” y para indicarlo los LEDs de “Función Manual ”y de “ADS” parpadean alternadamente.
2. Los botones “C” y “B” cambian los incrementos del eje X. El botón “C” sube el rayo.
3. Los botones “F” y “G” cambian los incrementos del eje Y. El botón “F” sube el rayo. LM800GR: los botones “H” y “I” cambian los incrementos del eje Y. El botón “H” sube el rayo.
4. Hay que subir o bajar el rayo láser para buscar el centro entre los puntos “A” y “B” en la pared (Fig. 12). La unidad reaccionará al cambio de los incrementos en el cuadrante X(+). La unidad no reacciona a los ajustes hasta que está forzada a volver a nivelar (rotar y volver a comprobar el punto “A”). Si la marca B está bajo A, hay que subir el rayo presionando el botón “C” Si B está arriba de A, hay que bajar el rayo presionando el botón “B”.
5. Apague el láser. Las correcciones se guardan automáticamente. Comprobar de nuevo la precisión de la rotación repitiendo los pasos 1-4 de la sección precedente. La comprobación se puede hacer en Modo Calibración con la ayuda del receptor láser. Ajustar cuanto sea necesario.
Comprobación de error en la rotación horizontal y calibración- Eje Y
Si desea comprobar también el eje “Y”, montar la unidad en un trípode y situarlo aprox. a 100 pies (30 metros) de distancia del objetivo, con el lado de control (cuadrante Y- ) encarando al objetivo; seguir los pasos 2 a 4 de “ Comprobación de error en la rotación horizontal –eje X). Calibrar como en “Calibración del error horizontal – eje X”, seleccionando el eje Y para calibrar y ajustar “+” y “­“ dentro del cuadrante Y+ (Fig. 13).
Si la calibración no sale bien, o si la diferencia entre los puntos A y B es demasiado grande para corregirla electrónicamente, póngase por favor en contacto con su proveedor o con un centro de Servicio Autorizado CST/berger.
Comprobación en la rotación vertical - Eje “Z” (sólo LM800)
1. Coloque la unidad en posición “tumbada” a 100 pies (30 metros) de una pared sobre una superficie nivelada lisa, con el panel de control hacia arriba y con un lado del instrumento hacia la pared (Fig. 14).
2. Cuelgue una plomada de por lo menos 8 pies (2,5 m) a una pared.
3. Presione el interruptor “A” y permita que la unidad se autonivele. Si necesario, ajuste la velocidad de rotación de la cabeza de una manera que se pueda ver claramente la línea láser sobre la pared. Ponga el láser paralelo a la pared y alinee la línea láser con la plomada.
Si esto no es posible, el eje Z debe ser calibrado.
LM800 - LM800GR • 27
Plomada hacia abajo / Desconexión del láser (Sólo LM800)
El botón encendido/apagado “A” además de encender y apagar el láser, conecta también la plomada hacia abajo mediante una segunda pulsación. Una tercera pulsación desconectaría la plomada, y así sucesivamente. Para apagar el láser, mantener presionado el botón “A” durante unos dos/tres segundos, hasta que los LEDs rojos de Manual y ADS parpadeen alternadamente.
SUSTITUCIÓN DE LA BATERIA
El color del LED indica el nivel de carga de la bateria.
Verde Carga total Rojo Carga baja, aunque en funcionamiento Rojo parpadeante Bateria agotada. Cargue o reemplace inmediatamente.
Bateria recargable
La bateria (57-NB1000) tendrá un rendimiento óptimo después de cinco ciclos de carga. La bateria tiene que ser cargada cuando esté montada en el láser. Asegúrese que el instrumento
está apagado, y conectar el enchufe con la toma que se encuentra en la parte lateral de la unidad (1 – Fig- 11)). Luego introduzca el enchufe del cargador en la toma de 220 V. El tiempo de carga completa es de aprox. 8 horas. Durante la carga se puede utilizar el láser, pero sólo una pequeña parte de la bateria recibirá carga.
CALIBRACIÓN
Su nivel láser es una unidad con grado de protección IP54 y calibrada en fábrica para trabajos precisos. Se recomienda hacer una prueba de calibración antes de comenzar a utilizarlo y luego periódicamente desde ese momento en adelante.
Permita al láser aprox. 60 segundos para que se nivele antes de controlarlo.
Comprobación de error en la rotación horizontal (Eje “X”)
1. Coloque la unidad a 100 pies (30 metros) de una pared encima de una superficie nivelada lisa o de un trípode con un adaptador de 5/8” x 11. Alinee el laser de manera que, con usted encarado con el panel frontal, la pared le quede a la derecha (Fig. 12).
2. Encienda el láser y permita que se autonivele por sí mismo. Utilizando el receptor láser, detecte el rayo láser y haga una marca “A” en la pared.
3. Aflojar el láser del trípode y girar el instrumento 180°. Asegúrese que la cota no ha cambiado y renivele la unidad.
4. Utilizando de nuevo el receptor, detecte el rayo láser y marque este nuevo punto como “B”.
5. Localice la línea central entre “A” y “B” y marque este punto como “C”. Si la diferencia vertical entre “A” y “C” o “B” y “C” es mayor que la tolerancia del instrumento, entonces proceda a su calibración.
26 • LM800 - LM800GR
AAuuttoonniivveellaacciióónn eelleeccttrróónniiccaa Horizontal si si Vertical no si I
nncclliinnaacciióónn mmaannuuaall
Con los botones del panel de control un eje hasta +/- 10% Mediante el mando a distancia doble inclinación hasta +/-10%
RRaannggoo ddee aauuttoonniivveellaacciióónn
+/- 5° +/- 5°
DDuurraacciióónn ddee llaa bbaatteerrííaa
más que 15 horas de uso continuado con bateria recargable ni­cad a plena carga (según temperatura)
VVeelloocciiddaadd ddee rroottaacciióónn
fijo 600 RPM variable 0,150,300,600 RPM
PPeessoo
2.5 libras (2,5 kg) con pilas
PPlloommaaddaa aarrrriibbaa
no si
PPlloommaaddaa aabbaajjoo
no si, mediante el boton “A”
BBaarrrriiddoo
no si
TTeemmppeerraattuurraa ddee ttrraabbaajjoo
de 22°F a 120°F (de –6°C a +49°C)
GGrraaddoo ddee pprrootteecccciióónn
IP67
SOLUCIÓN DE PROBLEMAS
Estas informaciones sirven como ayuda básica en caso de que el rendimiento del láser no sea óptimo.
BBaatteerrííaa rreeccaarrggaabbllee
– Para obtener el rendimiento mejor, la batería tiene que ser cargada completamente. Como en la mayoría de las baterias de níkel-cadmio, cuanto más cargada esté, más le costará cargarse completamente. La bateria tendrá un rendimiento óptimo después de cinco ciclos de carga.
EEll lláásseerr nnoo ssee aauuttoonniivveellaa oo llaa ccaabbeezzaa nnoo ggiirraa,, oo mmuueessttrraa uunn eerrrroorr
Asegurarse que el instrumento está dentro su campo de autonivelación. Reiniciar el procesador interno apagando el láser, esperando unos 15 segundos y encendiéndolo de nuevo. Si la cabeza gira, pero el láser no se autonivela, asegurarse que la Función Manual NO esté seleccionado.
Si no es posible solucionar el problema, póngase en contacto por favor con Su proveedor.
GARANTIA del láser
CST/Berger
a division of Stanley Works
, garantiza sus instrumentos electrónicos de medición contra deficiencias en materiales o mano de obra durante los dos años posteriores a la fecha de compra.
Los productos defectuosos serán reparados o reemplazados, a elección de CST/Berger, tras ser recibidos junto con su prueba de compra.
LM800 - LM800GR • 29
Calibración de posición tumbaba – eje Z (sólo LM800)
Apague la unidad presionando el interruptor”A”.
1. Encienda la unidad mientras mantiene presionado el interruptor “C”; luego soltar el botón “A”. El láser está ahora en el función “calibración” y para indicarlo los dos LEDs de “Función manual” y “ADS” parpadean alternadamente.
2. Los botones “C” y “B” cambian los incrementos del eje Z. El botón “C” produce un incremento positivo (+).
3. Seleccionar el botón “C” para rotar el rayo laser hacia la izquierda , o el botón “B” hacia la derecha para alinearlo con la línea de plomada. Por ejemplo: el rayo debe rotar hacia la izquierda para alinearse con la línea de plomada, entonces debe usar el botón “C” (ver Fig. 14).
4. Apague el láser. Las correcciones se guardan automáticamente.
Comprobar de nuevo la precisión de la rotación repitiendo los pasos 1-3 de la sección precedente. La comprobación se puede hacer en Modo Calibración.
MANTENIMIENTO Y CONSERVACIÓN
Después del uso, limpiar el instrumento utilizando un paño suave y seco para eliminar la humedad. No utilizar ni detergentes ni disolventes agresivos.
Guardar el láser en su maletín cuando no vaya a usarlo. En caso de no utilizar el aparato durante un largo período, se aconseja quitar la bateria.
MEDIDAS ECOLÓGICAS
Recuperación de materias primas en lugar de producir desperdicios. Aparato, accesorios y embalaje deberían someterse a un proceso de reciclaje. No tirar las pilas
gastadas entre los desperdicios domésticos o al fuego o al agua; eliminarlas de manera ecológica de acuerdo a las directrices legales.
DATOS TÉCNICOS
Descripción LM800GR LM800 DDiissttaanncciiaa
Hasta 2000 pies (610 m) en diámetro con el receptor láser
CCllaassee -- DDiiooddoo LLáásseerr
2M - 650 nm 2M - 635 nm “high power”
PPrreecciissiióónn
+/- 1/16 pul a 100 pies +/- 1/16 pul a 100 pies (+/- 1,5 mm a 30 m) (+/- 1,5 mm a 30 m)
PPrreecciissiióónn vveerrttiiccaall --
+/- 1/8 pul a 100 pies (+/- 6,4 mm a 30 m)
28 • LM800 - LM800GR