C-Squared CO Analyzer User Manual

C-Squared Inc. 1440 S State College Blvd, Unit 4L, Anaheim, CA 92806
Tel: (714) 999-2791, Fax: (714) 999-2928, sales@c-squaredinc.com, www.c-squaredinc.com
Introduction
The C-Squared CO Analyzer is designed to measure CO levels in the 1ppm to 100ppm range. It can be used to measure the CO content to assure safety in gas mixes that may be contaminated due to the introduction of CO from internal combustion engines or other pumping devices where CO is a bi-product. The Analyzer is designed to be able to verify CO concentration in cylinders as well as analyze closed spaces.
The C-Squared Analyzer has a digital display, an internally or externally mounted temperature compensated sensor with a 1 year life expectancy. The power is supplied by three AAA 1.5 volt batteries providing an expected operation life of one year before replacement is required.
The case has an environmentally sealed, potentiometer, on/off switch, long life sensor and digital panel meter. The Analyzer is water resistant and sealed to prevent moisture from affecting the internal components.
The Analyzer is shipped in a high impact case that can be used for storage or other purposes. The Analyzer is ready to use out of the box with no additional work other than checking on the calibration with an appropriate calibration gas at 50 or 100ppm.
Controls
The C-Squared Carbon Monoxide Analyzer has a splash proof on/off switch. When the switch is centered it is in the off position. When not in use, the switch should be in the off position to conserve battery life. When the switch is in the up position it is on. When the switch is flipped down the unit will remain in the off position.
When switched on, the analyzer’s display will indicate a CO reading. Please note that the analyzer has been calibrated prior to shipping but it should be checked routinely (see calibration section).
The low battery warning is a battery symbol in the left corner of the display. When present change the batteries prior to using the analyzer.
The display has a 1 ppm resolution and is sealed.
Incorporated
Carbon Monoxide Analyzer
Instruction Manual
Carbon Monoxide Analyzer Manual Page 2
C-Squared Inc. 1440 S State College Blvd, Unit 4L, Anaheim, CA 92806
Tel: (714) 999-2791, Fax: (714) 999-2928, sales@c-squaredinc.com, www.c-squaredinc.com
Gas Calibration:
Calibration is desirable prior to every use. For gas mixtures or room monitoring you should use a CO calibration of 50ppm or 100ppm concentration before use. This assures minimum deviation and greatest accuracy. The CO Analyzer is factory calibrated and marked for 93 ppm CO with calibration gas. As the sensor ages it would be correct to either send the unit back for recalibration or reset the calibration using the above concentrations of certified gas. For regular use expose the analyzer to the calibration gas and adjust the calibration knob until the display reads the listed concentration of the Calibration gas.
The analyzer is now ready for CO measurement.
WARNING: The analyzer is sensitive to partial pressure. Calibration must always be carried out at the same pressure as the CO measurement.
Carbon Monoxide Calibration:
Obtain the 50ppm or 100ppm Carbon Monoxide from a certified Distributor and measure the gas using a 100 to 300 cc per minute flow rate. Be sure to allow the reading to stabilize.
Loading...