portable dew point, pressure and temperature meter
0970 0055 DP 500 English, V1.0, 21.05.12
Page 2
DP 500 DP 500
Table of Contents
1. General information
Important information 3
Areas of application 3
Installation considerations 3
Notes on safety 3
2. What‘s in the box
3. Getting ready for measurement
4. Operation
Buttons and connectors 7
Symbols 7
Main screen 8
Basic operation 8
Calibration function 8
Special considerations 10
5. Technical data
6. Order information
7. Trademarks
8. Quality
9. Warranty
3
4
5
7
11
12
12
13
13
2
0970 0055 DP 500 English, V1.0, 21.05.12
Page 3
1. General information
Important
information
Area of
application
Installation
and operation
The operating instructions must be read in full and carefully observed before starting up the device. The manufacturer cannot be
held liable for any damage which occurs as a result of nonobservance or non-compliance with this manual.
Should the device be tampered with in any manner other than a
procedure which is described and specified in the manual, the warranty is cancelled and the manufacturer is exempt from liability.
CS Instruments is not liable for errors which may have slipped into
this operating manual.
The DP 500 is to be used for measuring the moisture, pressure and
temperature of air and gases.
Do not apply any corrosive gases to the sensor! Any use other than
that described here compromises the safety of persons and the
entire measuring system and is, therefore, not permitted.
The manufacturer is not liable for damage caused by improper or
non-designated use.
The measuring device must only be installed, connected, commissioned and maintained by qualified and authorized specialists (e.g.
electrical technicians) in full compliance with the instructions in this
manual, the applicable norms, legal regulations and certificates
(depending on the application).
The measuring device may only be modified or repaired if such work
is permitted in this instruction manual.
In order to achieve and maintain the accuracy stipulated in the technical data, the sensor must be installed according to the instructions
in this manual.
Notes on
• Do not exceed the pressure range of 1.6 MPa. Please contact
safety
• Observe permissible storage, transport and operating tempera-
0970 0055 DP 500 English, V1.0, 21.05.12
manufacturer for high pressure options.
tures.
3 14
Page 4
DP 500 DP 500
2. What’s in the box?
Depending on your order DP 500 comes with various options and
accessories which are explained in this chapter:
DP 500 instrument (0560 0500).
Parking chamber and closer.
Measuring chamber (0699 3492).
The Teflon hose with quick connect (0554 0003).
Charger and USB cable (0554
0018).
4 13
0970 0055 DP 500 English, V1.0, 21.05.12
Page 5
Instruction manual and calibration certificate
Hand strap
3. Getting ready for measurement
This chapter describes how to connect DP500 to the process for
measurement.
The parking chamber is
screwed on the sensor head to
keep the sensor dry. For measuring it has to be removed and
replaced by the measuring
chamber.
During removal use the closer
to seal the desiccant in the
parking chamber.
0970 0055 DP 500 English, V1.0, 21.05.12
5 12
Page 6
DP 500 DP 500
The measuring chamber is
screwed on the sensor head for
measurement. After finishing the
measurement please replace the
measuring chamber by the parking chamber.
The Teflon hose with quick connector is used to connect the
measuring chamber to the process. The hose is connected to
the 6mm connector at the chamber.
The quick connector is connected
to the process.
6 11
0970 0055 DP 500 English, V1.0, 21.05.12
Page 7
4. Operation
4.1 Buttons and connectors
Function keys
(used in model DP
On/Off key
SD card slot (for DP
520 only)
USB port
4.2 Symbols on screen
Symbol shows the battery status in % of
available energy.
The calibration is expired. It‘s recommended to
re-calibrate the sensor unit. Contact CS Service
General error indication. Please note down the
error codes and contact CS Service
0970 0055 DP 500 English, V1.0, 21.05.12
7 10
Page 8
DP 500 DP 500
4.3 Main screen
4.4 Basic operation
We didn’t describe the operation in detail in this user guide, as the
operation is easy and similar to what everyone is used to have on
their mobile phones. Please try the functions through the touch
screen and experience the features of this product.
4.5 Calibration function
DP 500/520 have a user calibration for dew point and pressure integrated. This chapter describes the special considerations when calibrating the instrument.
Pressure calibration
If the instrument is not showing 0 pressure at ambient conditions,
it’s recommended to perform a fast zero calibration. For that purpose
please use the calibration function and select ,<pressure calibration> . Follow the steps on the screen.
8 9
0970 0055 DP 500 English, V1.0, 21.05.12
Page 9
Dew point calibration
The instrument is calibrated ex factory and doesn’t need a recalibration within the specified period—usually within one year. However if the instrument has a slight drift due to aging, temperature or
other effects a one-point calibration can be performed. Performing a
dew point calibration is critical and following considerations should
be taken:
• Perform dew point calibrations at the working point. For
example if you measure at around -40 °C
at that point.
do the calibration
td
• Do not perform calibration at too high dew points, as it will
cause big errors at low dew points!
• We recommend calibration between -40 and -55 °C
If there is any doubt about the correct calibration process and result,
the calibration can be removed at any time. Please follow the instructions on the screen.
.
td
0970 0055 DP 500 English, V1.0, 21.05.12
Page 10
DP 500 DP 500
4.7 Special considerations
Please don’t remove and even
don’t touch the sinter cap
×
which protects the sensor
element from dust and particles. Wrong handling can effect or even destroy the sensitive sensor element..
The sensor unit can be removed by opening 2 screws on
the backside of the instrument.
The sensor unit can be replaced easily with a newly
calibrated one without the
need to return the complete
instrument.
The instrument comes with a
Teflon hose for the connection
to the compressed air system.
Please ensure that the hose
remains dry and clean. Wet
and contaminated hoses can
effect the measurement and
should be exchanged.
Dew point: ± 2 °C
Pressure: ± 0.005 MPa
Temperature: ± 0.3 °C
Stated uncertainty at:
Ambient / process temperature: 23 °C ± 3 °C
Ambient humidity: <90%, no condensation
T95: -50 —> -10 °Ctd: < 10 seconds
-10 —> -50 °C
g/m3, mg/m3, ppmv, g/kg
Dew point and moisture at atmospheric conditions
Ambient temp.: 0 … +50 °C
Storage temp.: -40 … +65 °C
Ambient humidity: < 90%, no condensation
EMC: IEC / EN 61326
USB charger: 5V, 2A (charging through USB port possible)
Battery life: 6 hours
@ -50 °Ctd
td
td
: < 5 minutes
Approvals
Certificates
0970 0055 DP 500 English, V1.0, 21.05.12
CE mark: The measuring system is conform with the
statutory requirements of the EC Directives.
CS Instruments has successful tested the
device and affixed the CE mark.
Page 12
DP 500 DP 500
Order information
Trademarks
6. Order information
Order No. Description
0600 0500
0560 0500
0699 3500
0554 0003
0554 0018
0554 0019
7. Trademarks
Bluetooth®
Registered trademark of the Bluetooth Organisation
DP 500 Set consisting of
DP 500 instrument
Parking/Measuring chamber for fast sensor response
Teflon hose with quick connector
USB charger with USB cable
Transport case DP 500
0970 0055 DP 500 English, V1.0, 21.05.12
Page 13
8. Quality at CS
Quality
Warranty
CS Instruments is specialized in practice oriented measurement instruments for industrial applications. Even though the company is just 7
years old, the founders have more than 20 years solid experience in
instrumentation.
Our strength is based on cooperation with Engineers and users in the
field of industrial measurement technology for many years. As a result
we offer instruments which are proofed and practical in the daily measurement tasks.
CS products require a high level of know-how and experience, which you
can rely on. Quality at CS Instruments means:
• 1-2 years warranty
• 100 % computerized tests in production
• Each instrument passes through a final test procedures
• Process within the company are documented and are based
on ISO 9001
• Employees are trained and highly motivated
• Internal audits monitoring the implemented processes
• More than 50.000 instruments are in operation world wide
9. Warranty
CS provides a warranty for this product of 24 months covering the
material and workmanship under the stated operating conditions from
the date of delivery. Please report any findings immediately and within
the warranty time guaranteed by us.
Excluded from this warranty is damage caused by improper use and
non-adherence to the instruction manual.
The warranty is also cancelled once the measuring instrument has
been opened provided this is not described in the instruction manual
for maintenance purposes. This is also the case if the serial number
has been changed, damaged or removed.
If in addition to the warranty service necessary repairs, adjustments or
similar are carried out, the warranty services are free of charge but
there is a charge for other services such as transport and packing
costs. Other claims, especially those for damage occurring outside the
instrument are not included unless responsibility is legally binding.
0970 0055 DP 500 English, V1.0, 21.05.12
Page 14
DP 500 DP 500
EC Declaration of Conformity
according to the guideline of the Board for Approximation
of Laws of the member states on the
electromagnetic compatibility (89/336/EWG)
Portable dew point meter DP 500 / DP 520
CS Instruments (Asia) as the manufacurer herewith declares that the above
mentioned humidity sensor correspond with the requirements of the following
guideline:
Electromagnetic compatibility (EMV) (89/336/EWG)
The assessment of the instrument was subject to the following
standards:
Emitted interference: EN 61326: 1997 + A1; 1998 + A2: 2001
CS Instruments (Shenzhen) Co., Ltd. Shenzhen, 15.05.2012
The Management
This declaration does not guarantee any product characteristics.
0970 0055 DP 500 English, V1.0, 21.05.12
Page 15
EC Declaration of Conformity
for
DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL of 27. January 2003 on waste electrical and electronic equipment (WEEE)
and
DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE
COUNCIL
of 27. January 2003 on the restriction of the use of certain hazardous substances in
electrical and electronic equipment (RoHS)
for the following instruments of CS Instruments:
Portable dew point meter DP 500 / DP 520
CS Instruments as the manufacturer herewith declares that the above instruments
and accessories belong to the category 9 (WEEE 2002/96/EC). Therefore the
above instruments are not affected by the directive RoHS 2002/95/EC and by the
material restriction.
In accordance with directive WEEE 2002/96/EC the measuring instruments specified above will be taken back from CS Instruments for disposal.
CS Instruments (Shenzhen) Co., Ltd. Shenzhen, 15.05.2012
The Management
This declaration does not guarantee any product characteristics.
Please do also adhere to the safety instructions stated in the enclosed documentation.
0970 0055 DP 500 English, V1.0, 21.05.12
15
Page 16
Asia Head Quarters
CS Instruments (Shenzhen) Co. Ltd.
303-2-22, Krystal Point, Jalan Sultan Azlan Shah, Bayan
Lepas, 11900 Penang, Malaysia
Tel: +60-4-643 1522
Fax: +60-4 643 1518
Email: sales@csinstrument.com.my
Website: http://www.csinstrument.com