![](/html/c6/c68b/c68b645126169c61f175e83677f6a281561680e3746e7afb3ed0781412ae188a/bg1.png)
Powered by
69.5 58.9 50.0 43.4 38.7 34.7 31.7 26.9 19.7 15.7 11.49 6.63 4.78
60.5 52.1 45.1 39.9 35.6 32.4 29.8 25.4 19.0 15.3 11.28 6.52 4.72
53.8 46.5 41.1 36.5 33.0 30.2 27.8 24.0 18.2 14.7 10.95 6.38 4.62
46.3 40.5 36.0 32.1 29.4 27.0 24.9 21.8 16.8 13.8 10.42 6.12 4.43
UPS12460
UPS 12460 is specially designed for high efficient discharge
application. Its characteristics are high energy density, small
footprint and high discharge efficiency. It can be used for more
than 260 cycles at 100% discharge in cycle service, up to 5 years
Specification
Cells Per Unit 6
Voltage Per Unit 12
Capacity
Weight Approx. 2.50 kg(5.51 lbs)
Maximum Discharge Current 130A(5sec)
Internal Resistance Approx. 18.0m
Operating Temperature Range
Nominal Operating Temperature Range 25
Float Charging Voltage 13.5 to 13.8 VDC/unit Average at 25
Recommended Maximum Charging 3.60A
Current Limit
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25
Self Discharge CSB Batteries can be stored for more than 6 months at
Terminal
Container Material
in standby service.
460W @ 5min-rateto Watt(1.60V)/pcs @25
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15
Storage: -15
3 (77 5 )
(77 ). Please charge batteries before using. For
25
higher temperatures the time interval will be shorter.
F2-Faston Tab 250
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
(77 )
~40 ( 5 ~104 )
~40 ( 5 ~104 )
(77 )
(77 )
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Dimensions :
Unit: mm (inch)
(http://www.csb-battery.com)
Constant Current Discharge Characteristics
F.V/Time 2MIN 3MIN 4MIN 5MIN 6MIN 7MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
77.2 63.0 52.7 44.9 39.7 35.6 32.3 27.3 19.9 15.9 11.57 6.65 4.80
66.0 56.9 48.6 42.4 37.9 34.0 31.1 26.5 19.6 15.6 11.44 6.60 4.75
Constant Power Discharge Characteristics
Overall Height (H) Container height (h) Length (L)
98.3±1.0(3.87± 0.04) 94.0±1.0 (3.70±0.04) 151.0±2.0 (5.95±0.08) 65.0±1.0 (2.56±0.04)
The system of manufacturer was certified
by TUV CERT according to ISO 9001,ISO 14001.
Unit:A
Unit:W
(25
(25
,77
,77
Width (W)
)
)
F.V/Time 2MIN 3MIN 4MIN 5MIN 6MIN 7MIN 8MIN 10MIN 15MIN 20MIN 30MIN 60MIN 90MIN
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
710 606 520 460 412 373 343 296 224 180 133 77.3 56.4
673 579 500 444 400 367 338 291 221 178 132 77.0 56.0
650 561 489 435 394 362 334 288 220 178 132 76.7 56.0
605 523 462 414 378 349 321 280 215 175 130.4 76.4 55.7
555 482 429 387 356 327 303 266 207 168 127.5 75.1 54.7
486 432 387 355 324 297 276 244 189 158 121.5 72.2 52.8
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
RA1308
![](/html/c6/c68b/c68b645126169c61f175e83677f6a281561680e3746e7afb3ed0781412ae188a/bg2.png)
UPS 12460
140
120
100
140
120
100
0.049
0.042
0.035
0.028
80
0.021
60
0.014
40
0.007
20
0.049
0.042
0.035
0.028
80
0.021
60
0.014
40
0.007
20
2.60
2.40
2.20
2.00
1.80
1.60
1.40
2.60
2.40
2.20
2.00
1.80
1.60
1.40
)Ratio
1PWx15Min
1PWx7.5Min
30 6 9 12 15 18
)Ratio
1PWx15Min
1PWx7.5Min
2.45V
0.025PA
68
14.70V
0.025PA
30 6 9 12 15 18
Charging Procedures
Charging Procedures
Application
Cycle Use
Standby
Temperature Set Point Allowable Range
25
25
Charge Voltage(V/Cell)
(77 )
(77 )
2.275 2.25~2.30
2.45 2.40~2.50
Max.Charge Current
0.1PA
P: For single cell wattage at 15 minute rate to 1.67V per cell.
Tel: +886-2-2880-5600
Fax: +886-2-2888-3300
+86-21-5064-1046
E-mail: chinasls@csb-battery.com
+86-10-5820-5336/5338
+86-10-58203053
Final Discharge
Voltage V/Cell
Discharge
Power(W)
1PW 0.62PW 0.47PW 0.25PW 0.16PW
1.75 1.70 1.60 1.30
(W)<0.25P 0.25P (W)<1.0P (W) 1.0P
0.1P>(W)
0.1P
EUROPE OFFICE
Tel: +31(0)180 418 140
Fax: +31(0)180 418 327
E-mail: eurosales@csb-battery.eu
Tel: +86-755-8831-6488/6396/16356
Fax: +86-755-8831-6548
E-mail: she@csb-battery.com.cn