CSB CSB GPL1272-F2FR Datasheet

Maintenance-Free Sealed Lead Acid Battery.
Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99%.
Design for Standby Power Applications
Design Life Float Charging Voltage
Up to 8 Years in Standby Service at 25
13.5 ~ 13.8 VDC/Unit at 25℃ (77)
Eurobat (20) : 10/12 YEARS LONG LIFE Equalization Charging Voltage
Self Discharge
Less than 10% after 90 days, can be stored up to 6 months at 25℃ (77℉);
Fully recharging is required before usage, and charged sooner if stored
Storage: -15 ~ 40 (5~104) at higher temperature than 25 (77℉).
Design according with IEC 61056-1/2:2012
Nominal Capacity
265A
--
Length (L) 150.9±2.0 mm 5.94±0.08 inch Width (W) 64.8±1.0 mm 2.55±0.04 inch Container Height (h) 94.3±1.0 mm 3.71±0.04 inch Overall Height (H) 98.6±1.0 mm 3.88±0.04 inch
F.V/Time 5 MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 32.3 20.3 15.1 8.65 4.99 3.60 2.84 2.05 1.34 0.882 0.719 0.375
1.67V 30.5 19.8 14.9 8.58 4.96 3.58 2.82 2.04 1.32 0.873 0.713 0.373
1.70V 29.5 19.4 14.7 8.53 4.94 3.57 2.80 2.02 1.31 0.866 0.708 0.371
1.75V 27.5 18.5 14.3 8.39 4.88 3.53 2.77 1.98 1.28 0.850 0.695 0.366
1.80V 24.7 17.1 13.5 8.11 4.75 3.46 2.70 1.93 1.25 0.821 0.672 0.357
1.85V 21.3 15.3 12.2 7.60 4.50 3.30 2.58 1.85 1.19 0.784 0.642 0.343
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR 20HR
1.60V 338 221 167 100 57.4 41.6 33.0 23.7 15.6 10.6 8.56 4.45
1.67V 325 217 166 99 57.2 41.4 32.8 23.6 15.5 10.5 8.55 4.43
1.70V 317 214 164 99 57.0 41.3 32.7 23.5 15.4 10.4 8.54 4.41
1.75V 298 206 160 97 56.3 40.9 32.4 23.4 15.3 10.3 8.53 4.35
1.80V 275 194 152 95 55.0 40.0 31.8 23.0 15.2 10.2 8.52 4.27
1.85V 246 177 139 89.2 52.2 38.1 30.4 22.1 14.8 10.1 8.51 4.12
Please refer to the official site for the latest rating confirmation. URL: www.csb-battery.com
Issued: 200930
Tel: +31(0)180-418-140 Tel: +886-2-2880-5600
Fax: +31(0)180-418-327
Fax: +866-2-2888-3300
Tel: +86-10-6597-8065/8165/8265
Fax: +86-10-6597-8565
7.2 Ah @20hr-rate to 1.75V per cell @25 (77)
GPL series
GPL 1272
Valve Regulated Lead Acid Battery
General
Nominal Operating Temperature : 25(77)
Discharge : -15 ~ 50 (5~122)
Charge: -15 ~ 40 (5~104)
Specification
Nominal Voltage
12V (6 cells per unit)
Short Circuit Current
Maximum Charge Current
2.16A
Terminal types
Weight
Approx. 2.60 Kg (5.73 lbs)
Maximum Discharge Current
100/130A (5sec)
Internal Resistance
Approx. 22.0mΩ
Constant Current Discharge Characteristics Unit: A (25, 77)
Constant Power Discharge Characteristics Unit: W (25, 77)
Sales Offices
Dimensions
Recognized under UL 1989,
and certified by ISO 9001, 14001, 45001, 50001.
BEIJING OFFICE (CHINA)
Tel: +86-755-8831-6488/6775/6075
Tel: +86-21-5046-1622/0833/0094
BUSINESS HEADQUARTERS
Tel: +886-2-2880-5600
Fax: +886-2-2888-3300
USA OFFICE
EUROPE (EMEA) OFFICE
TAIPEI OFFICE
Fax: +86-755-8831-6548
Fax: +86-21-5046-1046
F1/F2 Faston Tab Terminal (187/250)
Tel: +1-817-244-7777 / 1-(800)3-CSB-USA (272872)
Fax: +1-817-244-4445
SHENZHEN OFFICE (CHINA)
SHANGHAI OFFICE (CHINA)
Terminal tightening torque
Container Material
ABS (UL 94-HB) & Flame Retardant (94-V0) available upon request
Loading...