CryptOn CRT1081IRD-S2-MX User Manual

CRT1081IRD-S2-MX
USER’s MANUAL
USER’S MANUAL
CRT1081IRD-S2-MX
Compact size 8-channel multiplexing DVB-S2 IRD
Crypton, January 2013
CRT1081IRD-S2-MX
USER’s MANUAL
1.1 DESCRIPTION
1.2 PACKAGING CONTENTS
1.3 TECHNICAL SPECIFICATIONS
2.1 GENERAL SAFETY GUIDELINES
2.2 DEVICE SAFE OPERATION GUIDELINES
3.1 PHYSICAL DESCRIPTION
3.1.1 Front view........................................................................................................................................................................8
3.1.2 Rear view.........................................................................................................................................................................8
3.2 HARDWARE INSTALLATION
3.3 HARDWARE SETUP
3.3.1 Default network settings................................................................................................................................................10
3.3.2 Network and authorization settings reset......................................................................................................................10
3.3.3 Reset the device configuration to the factory settings...................................................................................................10
4.1 LOGING IN TO THE WEB INTERFACE
4.2 MAIN PAGE.
4.3 INPUT PAGE
4.3.1 Tuners setting up............................................................................................................................................................13
4.3.2 Common Interface setting up for CAM descrambling...................................................................................................14
4.3.3 ASI input state monitor..................................................................................................................................................15
4.4 ASI OUTPUT CONFIGURATION
4.5 DVB-OVER-IP CONFIGURATION
4.5.1 Device control IP configuration....................................................................................................................................16
4.5.2 DVB-over-IP streaming configuration..........................................................................................................................17
4.6 PROGRAM FILTERING
4.6.1 Input PSI/SI acuiring.....................................................................................................................................................19
4.6.2 Program service information preview...........................................................................................................................20
4.6.3 Program assignment to multiplexes...............................................................................................................................22
4.6.4 PSI/SI edit......................................................................................................................................................................23
4.6.5 CRT1081IRD-S2-MX output configuration...................................................................................................................25
4.7 NIT & EIT INSERTION
4.7.1 EIT program scadule broadcast....................................................................................................................................27
4.7.2 NIT broadcast................................................................................................................................................................28
4.8 OPTIONS MENU
4.8.1 Network configuration...................................................................................................................................................29
4.8.2 Authentication................................................................................................................................................................30
4.8.3 Time and Data setiings..................................................................................................................................................31
4.8.4 Firmware update............................................................................................................................................................32
4.8.5 Fimware recovery..........................................................................................................................................................34
4.8.6 Import and export configuration information................................................................................................................35
Crypton, January 2013 2
CRT1081IRD-S2-MX
USER’s MANUAL
1 General information
1.1 Description
CRT1081IRD-S2-MX – is a compact size eight channel DVB-S2 integrated receiver decoder with embedded four channel DVB remultiplexer. The device consists of 8 full featured DVB-S/S2 receivers, 4 DVB-ASI input interfaces, flexibly configurable 8-channel Common Interface for descrambling services and 4-channel DVB remultiplexer with DVB EPG processor, DVB-ASI and DVB-over-IP outputs, all in one 19-inch, 1U case. Such a compact and high integrated solution lets you build your network central station with an exceptional efficiency. WEB control interface lets you control all the system no matter where you are at the moment.
1.2 Packaging contents
CRT1081IRD-S2-MX 1
AC power cord 1
User’s manual 1
Crypton, January 2013 3
CRT1081IRD-S2-MX
USER’s MANUAL
1.3 Technical specifications
DVB-S/S2 receivers
Number of channels 8 Receiving frequency range 950-2150 MHz Input signal level -65…-25 dBm Nominal RF input impedance 75 Ohm Connector type IEC, F-type Max. LNB power 13/18 V, 400 mA Symbol rate 1-45 Mbaud(QPSK, 8PSK) FEC auto
Common Interface
Number of channels 8 Specifications EN50221, ETSI TS 101699
DVB-ASI inputs
Number of channels 4 Specifications EN 50083-9 Connector type IEC 169-8, BNC-type Operation modes auto detect Max. input bitrate, Mbit/s 213 (packet), 72 (byte)
DVB multiplexers
Number of input channels 12 Number of output channels 4 Specifications ISO IEC 13818-1 Max. output bitrate(all channels On) 300 Mbit/s(IP), 400 Mbit/s(ASI) PID restamping Yes SI/PSI processing Yes DVB EPG server Yes(embedded) DVB NIT server Yes(embedded) PCR jitter < 500 ns
DVB-ASI outputs
Number of output channels 4 Specifications EN 50083-9 Connector type IEC 169-8, BNC-type Operation modes Byte/Packet, 188 byte Max. output bitrate, Mbit/s 213 (packet), 72 (byte)
DVB-over-IP
Specification ETSI TS 102034 Streaming protocol UDP Streaming type Multicast/Unicast Number of DVB-over-IP streams 4 (ASI bound MPTS) Network interface 1 Gbit Ethernet
Control software HTTP server (Web) Control interface 100 Mbit Ethernet, TCP/IP Supply voltage 100-240 V Max. power 60 W Operational conditions
Crypton, January 2013 4
CRT1081IRD-S2-MX
USER’s MANUAL
Temperature 10…30 ºC Relative Humidity Up to 95 %, without condensation
Dimensions
Width, mm
440
Depth, mm
356
Height, mm
44
Crypton, January 2013 5
CRT1081IRD-S2-MX
USER’s MANUAL
2 Safety guidelines
2.1 General safety guidelines
Use the following guidelines when unsafe conditions exist or when potentially hazardous
voltages are present:
Always use caution and common sense.
To reduce the risk of electrical shock, do not operate equipment with the cover removed.
Repairs must be performed by qualified service personnel only.
Remember that voltages higher then 60 V DC or 30 V AC rms are dangerous.
2.2 Device Safe Operation Guidelines
Use only specified power supply and signals.
Have device power off when doing connections.
Proper cable types must be used.
Use the device under the specified environmental conditions.
Do not obstruct the ventilation system.
Crypton, January 2013 6
CRT1081IRD-S2-MX
USER’s MANUAL
3 Installation and setup
3.1 Physical Description
3.1.1 Front view
Fig. 1 Front view
1. Front panel with mounting holes;
2. 1Gbit Ethernet port for IP streaming of DVB services;
3. Device network/factory settings RESET button;
4. LEDs for tuners lock and CAM modules insertion indication;
5. 100Mbit Ethernet port for device control;
6. Common Interface slots for CAM modules.
3.1.2 Rear view
Fig. 2 Rear view
1. 8 DVB-S/S2 receiver LNB inputs;
2. 8 DVB-S/S2 receiver Loop outputs;
3. 4 DVB-ASI outputs from multiplexers;
4. 4 DVB-ASI multiplexers inputs;
5. Power socket;
6. Power switch.
Crypton, January 2013 7
CRT1081IRD-S2-MX
USER’s MANUAL
3.2 Hardware Installation
The following sequence of operations is recommended.
1. Unpack the device and check that all components are safe. If the device was taken to the installation room from a colder place wait at least one hour until condensed damp is dry.
2. Put the device at the place of operation and fix it properly. Special telecom rack is the best choice for multiple devices installation.
3. Provide necessary connections of LNB inputs, ASI inputs and outputs.
4. Connect the device Ethernet port to the same type port of the host PC with cross cord or use patch cord when Ethernet switch is used.
5.
Connect the power supply cord to an AC outlet
. Only specified voltage should be used. Pay a special
attention to use power cords and plugs with a ground wire.
The chassis is grounded through the three
prong AC receptacle.
6. Insert CAM Modules into Common Interface slots. To prevent damage of the interface only use EN50221 specified CAM Modules, push them gently no exceeding effort is required.
7. Switch the device power on. Short period LED lights signal the device is ready to operate.
Crypton, January 2013 8
CRT1081IRD-S2-MX
USER’s MANUAL
3.3 Hardware setup
3.3.1 Default network settings
The following default network settings are usually appear when fist time device power on. Please check that your Host PC network settings match to those default settings to make the the device connection.
MAC address 00:01:00:15:xx:xx IP address 192.168.0.100 Subnet Mask 255.255.255.0 Gateway IP address 0.0.0.0 Login admin Password admin
Note. Please see your device MAC address information attached to the accompanying documentation.
3.3.2 Network and authorization settings reset
You can reset the device network setting and access rights to the default any time you need. When the device is operating please carefully press IP RESET button on the front panel and hold for 1-2 seconds. The device will automatically start reboot for new settings to take effect. Use the default network and authorizatuin settings to access the device.
3.3.3 Reset the device configuration to the factory settings
You can reset the device configuration to the factory settings. When the device is operating please carefully press IP RESET button on the front panel and hold at least 20 seconds antil LEDs start blinking. The device will automatically start reboot for new settings to take effect. Factory configuration appears after reboot.
Crypton, January 2013 9
CRT1081IRD-S2-MX
USER’s MANUAL
4 Configuring the device using WEB interface
4.1 Loging in to the WEB interface
Before you start please check the following.
An IP address that identifies the CRT1081IRD-S2-MX Ethernet interface on the
LAN, and the Subnet Mask for the LAN segment.
A 10BaseT or 100BaseT network connection.
A grounded AC power outlet.
A PC or other workstation with a web browser connected to the network to access the
Web Interface to configure the unit for operation. It is recommended to use
the following list
of current or later Browser versions:
Google Chrome 3.0 Firefox 3.5 Opera 10 Internet Explorer 8.0
Note. 192.168.0.100 – is the default IP address
Enter current Login and Password to access the device settings.
Fig. 3 Authorization page
Note. Default password is admin.
Note. See 4.8.4 for authorization rights change.
Note. After 15 minutes of inactivity the device will disconnect automatically.
Crypton, January 2013 10
CRT1081IRD-S2-MX
USER’s MANUAL
4.2 Main Page.
After Logging process is successfully finished CRT1082IPE Main page opens, as shown in the following example.
Fig. 4 Main Page
Use menu on the left to select different device components such as Tuner/ASI inputs,
IPE/ASI outputs, Service filter etc.
Use Logout button in the left up conner to disconnect the device from your PC.
Reboot is used to restart the device software;
Find language selector and context help switch button in the right up conner.
You can find the component configuration window in the center of the screen or brief device
configuration instructions immediately after loging in.
Crypton, January 2013 11
Loading...
+ 23 hidden pages