Crydom Series LR Data Sheet

25-40
A
m
p
120/240/480 Vac - AC OUTPU
DC or AC Control
Zero Cross and Random Switching
Up to 1200V Transient Capability
SCR Output
PCB Mount
Low Profile
Manufactured in Crydom’s ISO 9001 Certified facility for optimum product
performance and reliability.
S
eries
L
R
T
MODEL NUMBERS
CURRENT DERATING CURVES
25A
30 25 20 15 10
Power Dissipation
5 0
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [˚C]
40A
60
1.38
(35.0)
1.0
(25.4)
1.5˚C/W
40
20
Power Dissipation
0
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [˚C]
MEC
HANICAL DIMENSION
All dimensions are in inches (millimeters)
+
Input
-
.500
(12.7)
APPROVALS
3˚C/W
1˚C/W
2˚C/W
AC
AC
Output
1˚C/W
2˚C/W
.5˚C/W
S
.78
(19.8)
.050 Typ. (1.2)
.25
(6.3)
UL (Pending) CSA (Pending) VDE (Pending)
Series LR
Rev. 111303 PAGE 1 OF 1
100
110
120
1.12
(28.4)
.39
(9.8)
LR1200480D25 LR1200480D40 LR1200480D25R
48-530
0.15-25 1200
250 260 500
0.1
1.6
1/2 cycle
1/2 cycle
0.5
DC Control
0.5
240V AC Control
11mA@ 240Vac
2
V/µsec]
LR600240D25 LR600240D25R
24-280
0.15-25 600
250
260
500
0.1
1.6
1/2 cycle
1/2 cycle
0.5
120 Vac Control
90-140 Vac
90 Vac
10 Vac
15mA@120 Vac
LR600240D40 LR600240D40R
24-280
0.15-40 600
400 660 500
0.1
1.6
1/2 cycle
1/2 cycle
Zero Cross Turn-on Random Turn-on
OUTPUT SPECIFICATIONS
95
Load Current Range [Arms] 0.15-40 Transient Over-Voltage [Vpk] 1200 Max. Surge Current Non-Repetitive, (16.6ms) [Apk] 400
2
Max. I t For Fusing (8.3 msec.) [A sec]
Base Plate Temp [˚C]
Min. Off-State dv/dt @ Max. Rated Voltage [ Max.Off-State Leakage @ Rated Voltage [mArms]
Max. On-State Voltage Drop @ Rated Current [Vpk] Max.Turn-On Time
90
Max. Turn-Off Time 1/2 cycle Power Factor (Min.) WIth Max. Load 0.5
100
INPUT SPECIFICATIONS
110
Base Plate Temp [˚C]
Control Voltage Range 4-32 Vdc
120
Must Turn On Voltage 4 Vdc Must Turn Off Voltage 1 Vdc Typical Input Current at 5Vdc 9 mA@ 5 Vdc
GENERAL SPECIFICATIONS
Dielectric Strength 2500 Vrms Insulation Resistance (Min.) @ 500 Vdc Max. Capacitance 8.0 pF Ambient Operating Temperature Range -30 to 80˚C Ambient Storage Temperature Range -30 to 125˚C
10
9
Ohm
MECHANICAL SPECIFICATIONS
Weight: (typical) 0.5 oz. (14.4 g)
GENERAL NOTES
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25˚C unless otherwise specified.Dielectric and insulation resistance are measured between input and output.Off-State dv/dt test method per EIA/NARM standard RS-443.Turn on time for random switching models is 0.1 ms (use suffix when ordering random turn on version)DC Input circuitry incorporates active current limiter.
Use suffix -120 for 120Vac control and -240 for 240Vac control.
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
WEB SITE: http://www.crydom.com
LR1200480D40R
48-530
660
500
0.1
1.6
1/2 cycle
180-260 Vac
180 Vac
10 Vac