![](/html/ec/ecc1/ecc1abc1b4ff92bb4112ca5215ac197d9569f5968f60af0d0ff0bb03969df815/bg1.png)
L
inea
S
eries
r
P
r
oportional
L
L
P
oad
C
C
ontroller
V
•
P
recise Proportional Load
C
ontrol
• O
ptically Is
• 0-5 V
•
0-5 Vdc CONTROL
EL NUMBERS
MOD
OUTPUT SPECIFICATIONS
Operating Voltage (60 Hz) [Vrms] 20-300 20-300 20-300 20-300 20-300
Load Current Range [Arms] .10-15 .10-25 .10-40 .15-75 .20-110
Transient Overvoltage [Vpk] 600 600 600 600 600
Max. Surge Current, (16.6ms) [Apk] 150 250 625 1000 1500
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 15 20 30 50
Thermal Resistance Junction to Case (R
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 94 260 1620 4150 9340
Maximum Voltage Drop (100% On) [Vpk] 1.6 1.6 1.6 1.6 1.6
Minmum Off-State dv/dt [V/µsec] 200 200 200 200 200
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5 0.5
0-10 Vdc CONTROL
4-20 mA CONTROL
) [ûC/W] 1.48 1.02 0.63 0.31 0.28
JC
d
I
nput Control Model
C
ontrol Circuit Requires no
A
djustment or Calibration
olated
c
, 0-10 V
d
c
, 4-20mA
s
5LPCV2415 5LPCV2425 5LPCV2440 5LPCV2475 5LPCV24110
10LPCV2415 10LPCV2425 10LPCV2440 10LPCV2475 10LPCV24110
20LPCV2415 20LPCV2425 20LPCV2440 20LPCV2475 20LPCV24110
The LPCV Linear Proportional
Controllers control loads up 110
Amps. Changes in the input signal
linearly vary the firing angle of the
thyristor load control device. Control
circuitry and power switch are in the
same package. The PS-120 (120V)
and PS-240 (240V) power supplies are
designed for use with the LPCV controller to provide the 20Vac required
in addition to the control voltage.
INPUT
Control Range (Nominal) 0-5 Vdc 0-10 Vdc 4-20 mA
Control Range Limits (Min/Msx) -0.5/10 Vdc -1.0/20 Vdc -0.5/25 mA
Turn-On Threshold .25 Vdc 0.5 Vdc 4.5 mA
Min. Input Impedance 12.7K Ohms 25K Ohms 460 Ohms
GENERAL
All parameters at 25˚ûC unless otherwise specified.
➀
Linear taper potentiometer 1-10K Ohm, 1/2 Watt.
②
50Hz models available.
➂
➃
FastFax Document No. 207
SERIES LPCV.
Rev. 111303
PAGE 1 OF 3
SPECIFICATIONS
NOTES
20Vac must be in phase with load.
© 2003 CRYDOM CORP, Specifications subject to change without notice.
TYPICAL APPLICATION
F
(20 mA)
(4 mA)
iring Angle v
10V
7.5V
5V
2.5V
0V
180
135
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
s
. I
nput
S
ignal
90
45
WEB SITE: http://www.crydom.com
5V
2.5V
0V
0
•
Infrared and Quartz Heaters
•
Resistive Heating Elements
•
Transformers
•
Rectified DC Motors
•
Thermal Forming Equipment
•
Blow Molding Equipment
•
Industrial Temperature Controllers
•
Conveyor Speed Control
•
Printing Applications
S
![](/html/ec/ecc1/ecc1abc1b4ff92bb4112ca5215ac197d9569f5968f60af0d0ff0bb03969df815/bg2.png)
L
inea
S
eries
r
P
r
oportional
L
L
P
oad
C
C
ontroller
V
All dimensions are in inches
(millimeters)
S
c
rew
T
orque
R
6-32 Screws - 10 in./lbs.,
equirement
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
s
:
8-32 TERMINALS
(2 PLACES)
.250 FASTON
TERMINALS
(5 PLACES)
PROPORTIONAL CONTROLLER
MOUNTING SLOT
0.17 (4.3) DIA.
2.21
(56.1)
1.52
(38.6)
OUTPUT
.62
(15.7)
GENERAL SPECIFICATION
S
Dielectric Strength, Signal to Load 2500 Vrms
Dielectric Strength, Signal to Base
Ambient Operating Temperature Range
2500 Vrms
-30 to 80˚C
Ambient Storage Temperature Range -40 to 125˚C
MEC
HANICAL
SPECIFICATION
S
Weight: (typical) 6.0 oz. (175g)
Encapsulation: Thermally Conductive Epoxy
Terminals: 8-32 Screws, .25 Inch Fastons
2.21
(56.1)
.30 Typ.
(7.6)
1.35 Max.
(40.6)
1.05
(26.7)
1.60 Max.
(40.6)
(66.5)
.12
(3.0)
2.62
2.50
(63.5)
1.00
(25.4)
6-32 TERMINALS
(2 PLACES)
2.00
(50.8)
INPUT
PS
120/PS240
1.00
(25.4)
OUTPUT
2.25
(57.2)
2.10
(53.3)
.250 FASTON
TERMINALS
(2 PLACES)
.12
(3.0)
WIRING DIAGR
OUTPUT
12
PROPORTIONAL CONTROLLER
76 543
-
-
20 Vac from Power
Supply Module ➃
PS-120 (120Vac)
PS-240 (240Vac)
See
note
➃
FastFax Document No. 207
SERIES LPCV.
Rev. 111303
PAGE 2 OF 3
From Control
0-5 Vdc
0-10 Vdc
4-20 mA
~
AM
POWER SUPPLY SPECIFICATION
➃
SPS
120
PS
240
Input Voltage 50/60Hz 120 Vac 240 Vac
Output Voltage 50/60Hz 20 Vac/100mA
Ambient Operating Temperature Range
20 Vac/100mA
-30 to 80˚C
Ambient Storage Temperature Range -40 to 125˚C
MEC
HANICAL
SPECIFICATION
S
Weight: (typical) 8.6 oz. (245g)
Encapsulation:
Thermally Conductive Epoxy
Terminals: 6-32 Screws, .25 Inch Fastons
12Vdc Output
For Manual Control
+
543
➁
Note: Not Used
if Connected to
Analog Card
NOTE: UNSUITABLE APPLICAT
The LPCV is not suitable for some load control applications including, but not limited to the following:
•
AC Motor Control
•
Three Phase Motors
•
Tranformers requiring pure sine wave input
•
Applications which cannot withstand thyristor noise
•
Zero Crossing Applications
©2003 CRYDOM CORP, Specifications subject to change without notice.
ION
S
Please contact Crydom's application engineering department for additional information and specific application questions.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506