MODEL NUMBERS
AC CONTROL HA6025 HA6050 HA6090 HA60125
DC CONTROL HD6025 HD6050 HD6090 HD60125
OUTPUT SPECIFICATIONS
➀
Nominal Line Voltage (±10%) [Vrms] 600 600 600 600
Operating Voltage Range (47-63 Hz) [Vrms] 48-660 48-660 48-660 48-660
Max. Load Current ➂[Arms] 25 50 90 125
Min. Load Current, [mArms] 40 40 40 150
Transient Overvoltage [Vpk] 1200 1200 1200 1200
Max. Surge Current, (16.6ms) [Apk] 250 625 1,200 1,750
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.7 1.7 1.7 1.7
Thermal Resistance Junction to Case (R
θJC
) [° C/W] 1.02 0.63 0.28 0.22
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1,620 6,000 12,700
Max. Off-State Leakage Current @ Rated Voltage [mArms]
➆
5555
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁ 500 500 500 500
Max. Turn-On Time ➄ 1/2 Cycle (DC Input), 10.0 msec (AC Input)
Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input)
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS ➀ DC CONTROL AC CONTROL AC CONTROL
(D PREFIX) (A PREFIX)➃ (E SUFFIX)
Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) 18-36 Vrms
Max. Reverse Voltage -32 Vdc --- ---
Max. Turn-On Voltage 3.0 Vdc 90 Vrms 18 Vrms
Min. Turn-Off Voltage 1.0 Vdc 10 Vrms 4.0 Vrms
Nominal Input Impedance See Note ➅ 60K Ohms 9.0K Ohms
Typical Input Current 2.0 mA➅ 2mA @ 120 Vrms, 4mA @ 240 Vrms 3mA @ 24 Vrms
GENERAL NOTES
➀All parameters at 25°C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ 24 Vac Input option, E suffix.
➄ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➅ Input circuitry incorporates active current limiter.
➆ No internal snubber.
• Zero Voltage and Random
Turn-On Switching
• Panel Mount
• 1200V Blocking Capability
• 600Vac - the preferred
choice in Canada
FastFax Document No.159
SERIES HA/HD60. 041900
PAGE 1 OF 3
Featuring state-of-the-art Surface
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
Series HA60/HD60
25-125Amp • 600 Vac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
• Integrated Overvoltage
Protection by Automatic
Self Turn-On (Suffix P)
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com.
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • Email: vertrieb@crydom.com

GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical) 3.0 oz. (86.5g)
Encapsulation: Thermally Conductive Epoxy
Terminals: Screws and Saddle Clamps Furnished, Unmounted
APPROVALS
UL E116950
CSA LR81689
VDE 10143 UG
Crydom Heat Sinks offer excellent
thermal management and are perfectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
FastFax Document No.159
SERIES HA/HD60. 053000
PAGE 2 OF 3
Series HA60/HD60
25-125Amp • 600 V ac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
(Screws dry without grease.)
Fastons:
Single pair (up to 25A)
Double pair* (up to 50A).
*
Caution: User must connect to both pairs
.90
(22.9)
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
BASE PLATE
.125 (3.2)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.87 REF.
(22.2)
12
OUTPUT
43
INPUT
1.00
(25.4)
1.80
(45.7)
.45
(11.4)
1.10
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
.90
(22.9)
FASTON
TERMINAL
.187 X .032
(2 PLCS.)
BASE PLATE
.125 (3.2)
FASTON TERMINAL
.250 X .032 (2 PLCS.)
1.87
(47.5)
.78
(19.8)
2.30
(58.4)
1.70
(43.2)
.87 REF.
(22.2)
12
OUTPUT
43
INPUT
1.00
(25.4)
1.80
(45.7)
.45
(11.4)
1.10
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
All dimensions are in inches (millimeters)
AVAILABLE OPTIONS
E
24 VAC Input (18-36 Vac)
Example: HA6025E
F Faston Terminals (Up to 50 Amp Models)
Example: HD6050F
Input Status LED.
G
Agencies Approval Pending
Example: HD6050G
Note: Control Voltage Range 4.5-32Vdc
for DC Control Models.
P Internal Overvoltage Protection.
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For
Capacitive Loads.
Agencies Approval Pending.
Example: HD6025P
-10 Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: HD6090-10
Ordering System: Combination of the
suffixes should be made in the following order:
EFPG-10.
Example: HA6050EFPG-10
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
BASE PLATE
.125 (3.2)
1.10
(27.9)
.45
(11.4)
OUTPUT
12
1.87
(47.5)
SOLID-STATE RELAY
INPUT
1.00
(25.4)
1.80
(45.7)
(43.2)
+--
34
2.30
(58.4)
1.70
6-32 TERMINAL
(2 PLACES)
8-32 TERMINAL
(2 PLACES )
.78
(19.8)
.90
(22.9)
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com.
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH,
Gewerbegebiet Im Schachen, D-66687 Nunkirchen, Germany • Email: vertrieb@crydom.com