Crydom Series HA, Series HD48 Data Sheet

Page 1
DataSheet
HA / HD48 Series
Panel Mount
Ratings from 12A to 125A @ 48-530 VAC
SCR output for heavy industrial loads
Zero turn-on or instantaneous turn-on outputs
UL/CSA/VDE Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
AC or DC control
Direct bond copper substrate
EMC compliant to Level 3
Direct power lead frame
Epoxy free design
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage 12A 25A 50A 75A 90A 110A 125A
4-32 VDC HD4812 HD4825 HD4850 HD4875 HD4890 HD48110 HD48125 90-280 Vrms HA4812 HA4825 HA4850 HA4875 HA4890 HA48110 HA48125 18-36 Vrms HA4812E HA4825E HA4850E HA4875E HA4890E HA48110E HA48125E
AVAILABLE OPTIONS
Series
Control Voltage A: 90-280 VAC D: 4-32 VDC AxxxxE: 18-36 VAC
48
Operating Voltage 48: 48-530 VAC
25
Rated Load Current 12: 12 Amps 25: 25 Amps 50: 50 Amps 75: 75 Amps 90: 90 Amps 110: 110 Amps 125: 125 Amps
KEAH P G
Termination Blank: Screw F: Quick Connect
(Up to 50 Amps models)
K: Hex standoffs
Overvoltage Protection Blank: Not Included P: Included
(8)
Input Status LED Blank: Not Included
(7)
G: Included
(14)
Required for valid part number For options only and not required for valid part number Not all part number combinations are available.
*
Contact Crydom Technical Support for information on the availability of a specific part number.
Snubber Blank: Not Included S: Included
S H
Switching Type Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On
-10
Thermal Pad Blank: Not Included H: Included
(9)
OUTPUT SPECIFICATIONS
Description 12A 25A 50A 75A 90A 110A 125A
Operating Voltage (47-440Hz) [Vrms] (2) 48-530 48-530 48-530 48-530 48-530 48-530 48-530 Transient Overvoltage [Vpk] 1200 1200 1200 1200 1200 1200 1200 Maximum Off-State Leakage Current @ Rated Voltage [mArms] (3) 1 1 1 1 1 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] 500 500 500 500 500 500 500 Maximum Load Current [Arms] (4) 12 25 50 75 90 110 125 Minimum Load Current [mArms] 150 150 150 150 150 150 150 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 134/140 239/250 597/625 954/1000 1145/1200 1432/1500 1670/1750 Maximum On-State Voltage Drop @ Rated Current [Vrms] 1.15 1.15 1.15 1.15 1.15 1.15 1.15 Thermal Resistance Junction to Case (Rjc) [°C/W] 1.03 0.8 0.45 0.3 0.27 0.25 0.22 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 66/60 285/259 1770/1629 4555/4150 6560/5976 10249/9338 13950/12709 Minimum Power Factor (at Maximum Load) (8) 0.5 0.5 0.5 0.5 0.5 0.5 0.5
(1)