Crydom Series EZ Data Sheet

AC CONTROL (120Vac)
EZ240A12 EZ240A18 EZ480A12 EZ480A18
MODEL NUMBERS
(24Vac)
EZE240A12 EZE240A18 EZE480A12 EZE480A18
DC CONTROL (5Vdc) EZ240D12 EZ240D18 EZ480D12 EZ480D18
(24Vdc) EZE240D12 EZE240D18 EZE480D12 EZE480D18
Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-660 48-660 Max. Load Current [Arms] 12 18 12 18 Min. Load Current, [mArms] 150 150 150 150
Transient Overvoltage [Vpk]
600 600 1200 1200
Max. Surge Current, (16.6ms) [Apk]
150 200 150 200
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.5 1.5 1.5 1.5
Thermal Resistance Junction to Case (R
θJC
) [°C/W] 2.0 1.1 2.0 1.1
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 95 170 95 170 Max. Off-State Leakage Current @
Rated Voltage [mArms]
0.1 0.1 0.1 0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] 500 500 500 500 Max. Turn-On Time 1/2 Cycle (DC Input), 10.0 msec (AC Input) Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input) Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS DC CONTROL
AC CONTROL
Nominal Voltage
5Vdc
5Vdc 24Vdc
120Vac 24Vac
EZE240D12
EZ240A12 EZE240A12
MODEL NUMBERS EZE240D18
EZ240A18 EZE240A18
EZ240D12
EZ480D12 EZE480D12
EZ480A12 EZE480A12
EZ240D18
EZ480D18 EZE480D18
EZ480A18 EZE480A18
Control Voltage Range
3-15 Vdc
4-15 Vdc 15-32 Vdc
90-140 Vrms 18-36 Vrms
Max. Turn-On Voltage
3.0 Vdc
4.0 Vdc 15.0 Vdc
90.0 Vrms 18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc 1.0 Vdc
10.0 Vrms 2.0 Vrms
Nominal Input Impedance
300 Ohms
240 Ohms 1500 Ohms
10.6k Ohms 1.8k Ohms
Typical Input Current @ Nominal Voltage
15 mAdc
15 mAdc 15 mAdc
10 mArms 10 mArms
GENERAL NOTES
All parameters at 25° C unless otherwise specified.Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1240V, DC control models only, all others 2500Vrms.Heat sinking required, for derating curves see page 2.Off-State leakage for snubbered
version (suffix S) is 10.0 mArms.
Turn-on time for random turn-on versions
is 0.1 msec (DC Control Models).
• Low Leakage
• Quick Connect Terminals
• SCR Output
• 24V Control Available (EZE Models)
The Series EZ SPST-NO AC output relays offer a low profile package with the convenience of quick con-
FastFax Document No.160 SERIES EZ.101000, PAGE 1 OF 2
nect terminals. The Series EZ is the preferred choice for replacement of 120V and 240V Electro-mechanical relays. Output consists of an SCR switch and is available in Zero-Cross and Random Turn-On (Phase Controlable) versions.
Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability.
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
EZ240D5
24-280
5 150 600
40
1.5
2.0 95
0.1
500
0.5
5Vdc
EZ240D05
4-15 Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13 mAdc
For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside HouseBrook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com. GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH
AVAILABLE OPTIONS
S Internal Snubber
Example: EZ240D12S
R Random Turn-On Switching (240V Only)
Example: EZ240D12R, EZ240D12RS
EZ240D5R
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms* Insulation Resistance (Min.) @ 500 Vdc 109Ohm Max. Capacitance Input/Output 8 pF Ambient Operating Temperature Range -40 to 80°C Ambient Storage Temperature Range -40 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical) 1.5 oz. (43g) Encapsulation: Thermally Conductive Epoxy Terminals: .25 Inch Faston
*240V, DC Control Models Only.
All dimensions are in inches (millimeters)
APPROVALS
UL E116950 CSA LR81689 VDE 10139 UG (240V DC Control Only)
2.63
(66.8)
2.24
(56.9)
1.50
(38.1)
.49
(12.4)
1.00
(25.4)
1.73
(43.9)
.95
(24.1)
.40
(10.2)
.12
(3.0)
SOLID-STATE RELAY
1
OUTPUT
INPUT
2
3+ 4
FASTON TERMINAL .250 X .032 4 PLCS.
.197 DIA. (2 PLCS)
CURRENT DERATING CURVES
Crydom Heat Sinks offer excellent ther­mal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details.
FastFax Document No.160 SERIES EZ.101000, PAGE 2 OF 2
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: ---DC CONTROL
5A
10°C/W
NO HEATSINK
5°C/W
110
115
Base Plate Temp [°C]
120
6 5 4 3 2
Power Dissipation
1
2 3 5 104 20 40 60 80
1
Load Current [Arms] Max Ambient Temp. [°C]
15
10
5
Power Dissipation [W]
0
2 4 8 10 126 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
12A
NO HEATSINK
6°C/W
4°C/W
2°C/W
112
116
120
124
Base Plate Temp [°C]
18
12
6
Power Dissipation [W]
0
3 6 12 15 189 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
18A
NO HEATSINK
5°C/W
2°C/W
112
116
120
Base Plate Temp [°C]
124
For recommended applications and more information contact: USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280 Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191 UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House Brook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com. GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH,