AC CONTROL (120Vac)
EZ240A12 EZ240A18 EZ480A12 EZ480A18
MODEL NUMBERS
(24Vac)
EZE240A12 EZE240A18 EZE480A12 EZE480A18
DC CONTROL (5Vdc) EZ240D12 EZ240D18 EZ480D12 EZ480D18
(24Vdc) EZE240D12 EZE240D18 EZE480D12 EZE480D18
OUTPUT SPECIFICATIONS
➀
Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-660 48-660
Max. Load Current ➃ [Arms] 12 18 12 18
Min. Load Current, [mArms] 150 150 150 150
Transient Overvoltage [Vpk]
600 600 1200 1200
Max. Surge Current, (16.6ms) [Apk]
150 200 150 200
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.5 1.5 1.5 1.5
Thermal Resistance Junction to Case (R
θJC
) [°C/W] 2.0 1.1 2.0 1.1
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 95 170 95 170
Max. Off-State Leakage Current @
Rated Voltage [mArms]
➄
0.1 0.1 0.1 0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁ 500 500 500 500
Max. Turn-On Time ➅ 1/2 Cycle (DC Input), 10.0 msec (AC Input)
Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input)
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
INPUT SPECIFICATIONS ➀ DC CONTROL
AC CONTROL
Nominal Voltage
5Vdc
5Vdc 24Vdc
120Vac 24Vac
EZE240D12
EZ240A12 EZE240A12
MODEL NUMBERS EZE240D18
EZ240A18 EZE240A18
EZ240D12
EZ480D12 EZE480D12
EZ480A12 EZE480A12
EZ240D18
EZ480D18 EZE480D18
EZ480A18 EZE480A18
Control Voltage Range
3-15 Vdc
4-15 Vdc 15-32 Vdc
90-140 Vrms 18-36 Vrms
Max. Turn-On Voltage
3.0 Vdc
4.0 Vdc 15.0 Vdc
90.0 Vrms 18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc 1.0 Vdc
10.0 Vrms 2.0 Vrms
Nominal Input Impedance
300 Ohms
240 Ohms 1500 Ohms
10.6k Ohms 1.8k Ohms
Typical Input Current @ Nominal Voltage
15 mAdc
15 mAdc 15 mAdc
10 mArms 10 mArms
GENERAL NOTES
➀ All parameters at 25° C unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ 240V, DC control models only, all others 2500Vrms.
➃ Heat sinking required, for derating curves see page 2.
➄ Off-State leakage for snubbered
version (suffix S) is 10.0 mArms.
➅ Turn-on time for random turn-on versions
is 0.1 msec (DC Control Models).
• Low Leakage
• Quick Connect Terminals
• SCR Output
• 24V Control Available
(EZE Models)
The Series EZ SPST-NO AC output
relays offer a low profile package
with the convenience of quick con-
FastFax Document No.160
SERIES EZ.101000, PAGE 1 OF 2
nect terminals. The Series EZ is the
preferred choice for replacement of
120V and 240V Electro-mechanical
relays. Output consists of an SCR
switch and is available in Zero-Cross
and Random Turn-On (Phase
Controlable) versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
EZ240D5
24-280
5
150
600
40
1.5
2.0
95
0.1
500
0.5
5Vdc
EZ240D05
4-15 Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13 mAdc
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com.
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH
AVAILABLE OPTIONS
S Internal Snubber
Example: EZ240D12S
R Random Turn-On Switching (240V Only)
Example: EZ240D12R, EZ240D12RS
EZ240D5R
GENERAL SPECIFICATIONS
Dielectric Strength ➂ 50/60Hz Input/Output/Base 4000 Vrms*
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical) 1.5 oz. (43g)
Encapsulation: Thermally Conductive Epoxy
Terminals: .25 Inch Faston
*240V, DC Control Models Only.
All dimensions are in inches (millimeters)
APPROVALS
UL E116950
CSA LR81689
VDE 10139 UG (240V DC Control Only)
2.63
(66.8)
2.24
(56.9)
1.50
(38.1)
.49
(12.4)
1.00
(25.4)
1.73
(43.9)
.95
(24.1)
.40
(10.2)
.12
(3.0)
SOLID-STATE RELAY
1
OUTPUT
INPUT
2
3+ 4
FASTON
TERMINAL
.250 X .032
4 PLCS.
.197 DIA.
(2 PLCS)
CURRENT DERATING CURVES
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet for
all the details.
FastFax Document No.160
SERIES EZ.101000, PAGE 2 OF 2
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
©2000 CRYDOM CORP, Specifications subject to change without notice.
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: ---DC CONTROL
5A
10°C/W
NO HEATSINK
5°C/W
110
115
Base Plate Temp [°C]
120
6
5
4
3
2
Power Dissipation
1
2 3 5 104 20 40 60 80
1
Load Current [Arms] Max Ambient Temp. [°C]
15
10
5
Power Dissipation [W]
0
2 4 8 10 126 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
12A
NO HEATSINK
6°C/W
4°C/W
2°C/W
112
116
120
124
Base Plate Temp [°C]
18
12
6
Power Dissipation [W]
0
3 6 12 15 189 20 40 60 80
Load Current [Arms] Max Ambient Temp. [°C]
18A
NO HEATSINK
5°C/W
2°C/W
112
116
120
Base Plate Temp [°C]
124
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: intsales@crydom.com.
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH,