MODEL NUMBERS DC CONTROL AC CONTROL
DC60S3-B
DC60S3 DC60S5 DC60S7 DC60SA3 DC60SA5 DC60SA7
OUTPUT SPECIFICATIONS
Operating Voltage Range [Vdc] 3-60 3-60 3-60 3-60 3-60 3-60
Load Current Range2[Adc] .02-3 .02-5 .02-7 .02-3 .02-5 .02-7
Max. Surge Current, (1 sec) [Adc] 6 1 0 14 6 10 14
Thermal Resistance Junction to Case (RJC) [°C/W] 2.2 2.2 2.2 2.2 2.2 2.2
Max. Turn-On Time [msec] 0.1 0.1 0.1 10 10 10
Max. Turn-Off Time [msec] 0.3 0.3 0.3 40 40 40
1
3-60
.02-3
6
1.3
q
2.2
0.3
0.3
0.1
DC60S5-B
3-60
.02-5
10
1.5
2.2
0.3
0.3
0.1
DC60S7-B
3-60
.02-7
14
1.7
2.2
0.3
0.3
0.1
DC60SA3-B
3-60
.02-3
6
1.3
2.2
0.3
40
10
DC60SA5-B
3-60
.02-5
10
1.5
2.2
0.3
40
10
DC60SA7-B
3-60
.02-7
14
1.7
2.2
0.3
40
10
INPUT SPECIFICATIONS
Configuration Normally Open Normally Open
Control Voltage Range 3.5-32 Vdc 90-280 Vrms
Max. Turn-On Voltage 3.5 Vdc 90 Vrms
Min. Turn-Off Voltage 1.0 Vdc 10 Vrms
Nominal Input Impedence 1500 Ohms 60K Ohms
Typical Input Current 2.2mA @ 5 Vdc 2mA @ 120 Vrms, 4mA @ 240 Vrms
GENERAL NOTES
1
DC CONTROL AC CONTROL
Normally Closed (-B)
3.5-32 Vdc
1.0 Vdc
3.5 Vdc
1500 Ohms
2.2mA @ 5 Vdc
©2006 CRYDOM CORP, Specifications subject to change without notice.
1 All parameters at 25°C unless otherwise specified. 2 Heat sinking required, for derating curves see page 2.
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
SERIES DC60. Rev. 050406 PAGE 1 OF 2
Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
Normally Closed (-B)
90-280 Vrms
10 Vrms
90 Vrms
60K Ohms
2mA @ 120 Vrms, 4mA @ 240 Vrms
AC CONTROL MODELS PIN 3: AC CONTROL PIN 4: AC CONTROL DC CONTROL MODELS PIN 3 : + DC CONTROL PIN 4: -- DC CONTROL
Input and output polarity must be observed.
Inductive loads must be diode suppressed.
4 1 (+)
OUTPUT
SSR
INPUT
3 2 (
Series DC60
3-7Amp • 60 Vdc - DC OUTPUT
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz (input/output/base) 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 10 9 Ohm
Max. Capacitance Input/Output 8 pF
Ambient Operating Temperature Range -30 to 80°C
Ambient Storage Temperature Range -30 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical) 3.0 oz. (86.5g)
Encapsulation: Thermally Conductive Epoxy
Terminals: Screws and Saddle Clamps Furnished, Unmounted
1.10
MOUNTING HOLE/SLOT
0.17 (4.3) DIA.
LOAD
(+)
-)
(-)
1.87
(47.5)
(27.9)
.45
(11.4)
OUTPUT
+- -
1 2
INPUT
1.70
(43.2)
3 4
+ --
2.30
(58.4)
8-32 TERMINAL
(2 PLACES )
All dimensions are in inches (millimeters)
Screw Torque Requirements:
6-32 Screws - 10 in. lbs., 8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.)
Transient Protection
All loads are inductive, even ones that are not so labeled. An inductive load will produce harmful transient voltages when it is turned off. Diodes should be fast recovery type with PIV rated greater than supply voltage.
3A
12
8
7.5°C/W
NO HEAT SINK
4
Power Dissipation
0
1 2 1.5 2.5 3 20 40 60 100 80
Load Current [Arms] Max Ambient Temp. [°C]
Crydom Heat Sinks offer excellent thermal management and are per­fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom's Heat Sink specification sheet for all the details.
1.00
(25.4)
1.80
(45.7)
CURRENT DERATING CURVES
Base Plate Temp [°C]
12
8
4
Power Dissipation
0
1 2 4 5 3 20 40 60 100 80
12
8
4
Power Dissipation
0
1 2 4 5 6 7 3 20 40 60 100 80
100
105
110
115
120
6-32 TERMINAL (2 PLACES)
.78
(19.8)
.90
(22.9)
5A
100
2°C/W
7.5°C/W
NO HEAT SINK
5°C/W
105
110
115
120
Load Current [Arms] Max Ambient Temp. [°C]
7A
100
2°C/W
7.5°C/W
NO HEAT SINK
Load Current [Arms] Max Ambient Temp. [°C]
© 2006 CRYDOM CORP, Specifications subject to change without notice.
5°C/W
105
110
115
120
Base Plate Temp [°C]
Base Plate Temp [°C]
SERIES DC60. Rev. 050406 PAGE 2 OF 2
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
Loading...