1.5
A
S
eries
m
p
•
120/240 Vac • AC OUTPUT
C
X
L
o
w
P
241
rofile
SI
P
CURRENT DERATING CURVE
1.5
1.0
0.5
LOAD CURRENT (AMPS)
20 40 60 80
AMBIENT TEMPERATURE (ºC)
Max. Load Current vs. Temp.
.300 (7.6)
0.69
MAX.
(17.5)
.300 TYP.
(7.6)
APPROVALS
FastFax Document No.105
SERIES CX241
Rev. 111203
PAGE 1 OF 1
CONTROL LOAD
43 2 1
.200
(5.1)
All dimensions are in inches (millimeters)
UL E116950
CSA LR81689
VDE 5921 UG
.700
(17.8)
1.70
(43.1)
1.100
(27.9)
PIN 1: AC LOAD
PIN 2: AC LOAD
PIN 3: +DC CONTROL
PIN 4: -DC CONTROL
.050
TYP.
(1.3)
.100
(2.5)
.040 (1.0) DIA.
(4 PLACES)
• Low Minimum Operating
Current
• SCR Output
•
Crydom’s Patented Design
The CX241 AC Relays are 1.5A rated
SPST-NO low profile SIP solid state
relays offering the Series ASO circuit
with the popular CXpin-out. They are
designed for switching highly inductive,
low current loads such as solenoids.
Available in either zero voltage or random switching versions (R suffix).
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
INPUT SPECIFICATIONS
Control Voltage Range 4-10 Vdc
Nominal Input Impedance 300 Ohm
Typical Input Current @ 5 Vdc 15 mAdc
Must Turn On Voltage 4.0 Vdc
Must Turn Off Voltage 1.0 Vdc
OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz) 12-280 Vrms
Load Current Range .025-1.5 Arms
Transient Over-Voltage 600 Vpk
Max. Surge Current, (16.6ms) 40 Apk
Min. Off-State dv/dt @ Max. Rated Voltage
Max.Off-State Leakage @ Rated Voltage 0.1 mArms
Max. On-State Voltage Drop @ Rated Current
Max.Turn-On Time 1/2 cycle 0.1 msec
Max. Turn-Off TIme 1/2 cycle
Power Factor (Min.) WIth Max. Load 0.5
GENERAL SPECIFICATIONS
Dielectric Strength ➁ 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc ➁ 10
Max. Capacitance 8.0 pF
mbient Operating Temperature Range -30 to 80ºC
A
Ambient Storage Temperature Range -30 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical) 0.4 oz. (11 g)
Encapsulation: Thermally Conductive Epoxy
GENERAL NOTES
MODEL NO. CX241 CX241R
➀
➀
➂ 500 V/µsec
1.5 Vpk
9
Ohm
© 2003 CRYDOM CORP, Specifications subject to change without notice.
➀ All parameters at 25ºC unless otherwise specified.
➁ Dielectric and insulation resistance are measured between input and output.
➂ Off-State dv/dt test method per EIA/NARM standard RS-443.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506