Crydom Series CX241 Data Sheet

1.5
A
S
eries
m
p
120/240 Vac • AC OUTPUT
C
X
L
o
w
P
241
rofile
SI
P
CURRENT DERATING CURVE
1.5
1.0
0.5
LOAD CURRENT (AMPS)
20 40 60 80
AMBIENT TEMPERATURE (ºC)
Max. Load Current vs. Temp.
.300 (7.6)
0.69 MAX. (17.5)
.300 TYP.
(7.6)
APPROVALS
FastFax Document No.105 SERIES CX241
Rev. 111203 PAGE 1 OF 1
CONTROL LOAD
43 2 1
.200 (5.1)
All dimensions are in inches (millimeters)
UL E116950 CSA LR81689 VDE 5921 UG
.700
(17.8)
1.70
(43.1)
1.100 (27.9)
PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: -DC CONTROL
.050 TYP. (1.3)
.100 (2.5)
.040 (1.0) DIA.
(4 PLACES)
Low Minimum Operating
Current
SCR Output
Crydom’s Patented Design
The CX241 AC Relays are 1.5A rated SPST-NO low profile SIP solid state relays offering the Series ASO circuit with the popular CXpin-out. They are designed for switching highly inductive, low current loads such as solenoids. Available in either zero voltage or ran­dom switching versions (R suffix).
Manufactured in Crydoms ISO 9001 Certified facility for optimum product performance and reliability.
INPUT SPECIFICATIONS
Control Voltage Range 4-10 Vdc Nominal Input Impedance 300 Ohm Typical Input Current @ 5 Vdc 15 mAdc Must Turn On Voltage 4.0 Vdc Must Turn Off Voltage 1.0 Vdc
OUTPUT SPECIFICATIONS
Operating Voltage Range (47-63 Hz) 12-280 Vrms Load Current Range .025-1.5 Arms Transient Over-Voltage 600 Vpk Max. Surge Current, (16.6ms) 40 Apk Min. Off-State dv/dt @ Max. Rated Voltage Max.Off-State Leakage @ Rated Voltage 0.1 mArms Max. On-State Voltage Drop @ Rated Current Max.Turn-On Time 1/2 cycle 0.1 msec Max. Turn-Off TIme 1/2 cycle Power Factor (Min.) WIth Max. Load 0.5
GENERAL SPECIFICATIONS
Dielectric Strength 4000 Vrms Insulation Resistance (Min.) @ 500 Vdc 10 Max. Capacitance 8.0 pF
mbient Operating Temperature Range -30 to 80ºC
A
Ambient Storage Temperature Range -30 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical) 0.4 oz. (11 g) Encapsulation: Thermally Conductive Epoxy
GENERAL NOTES
MODEL NO. CX241 CX241R
500 V/µsec
1.5 Vpk
9
Ohm
© 2003 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25ºC unless otherwise specified.Dielectric and insulation resistance are measured between input and output.Off-State dv/dt test method per EIA/NARM standard RS-443.
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
WEB SITE: http://www.crydom.com
Loading...