Crydom Series 53TP Data Sheet

25-50
A
S
m
p
eries
240/480 Vac - 3 PHASE
53
T
P
•SCR
•LED S
O
utput
tatu
P
rotective
s Indicator
C
over Available
(Part No. KS300)
P
anel Mount
I
ntegrated Overvoltage
P
rotection by Automati
S
elf
T
urn-On
MODEL NUMBERS
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] 48-530 48-530 48-530 48-530 Load Current Range[Arms] .05-25 .05-50 .05-25 .05-50 Transient Overvoltage [Vpk] 1200 1200 1200 1200 Max. Surge Current, (16.6ms) [Apk] 250 625 250 625 Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6 Thermal Resistance Junction to Case (R Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1620 260 1620
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10 Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] 500 500 500 500 Max. Turn-On Time 1/2 Cycle 1/2 Cycle 10.0 msec 10.0 msec Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 40.0 msec 40.0 msec Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
) [˚C/W] 1.02 .63 1.02 .63
θJC
(
S
uffix
D53TP
25D D53TP
c
P)
Three-phase solid state relays switch up to 530 Vrms directly to loads such as motors, transformers, heating elements, etc. Available with either AC or DC input (coil) control in zero-voltage or random turn-on switching versions.
Manufactured in Crydom’s ISO 9001 Certified facility for optimum product performance and reliability.
50D A53TP
25D A53TP
50D
INPUT
Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz) Max. Turn-On Voltage 3.0 Vdc 90 Vrms Min. Turn-Off Voltage 1.0 Vdc 10 Vrms Nominal Input Impedance 450 Ohms 54.8k Ohms Typical Input Current 10mA @ 5 Vdc 2.2mA @ 120 Vrms, 4.4mA @ 240 Vrms
GENERAL
All parameters at 25ºC and per section unless otherwise specified.Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1Heat sinking required, for derating curves see page 2.Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
FastFax Document No.161 SERIES53TP. Rev. 111003 PAGE 1 OF 2
SPECIFICATIONS
NOTES
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
DC CONTROL
©2003 CRYDOM CORP, Specifications subject to change without notice.
WEB SITE: http://www.crydom.com
AC CONTROL
A53DP50D, D53DP50D
180
120
150
90
25-50
A
S
m
p
eries
240/480 Vac - 3 PHASE
53
T
P
AVAILABLE OPT
-10
Non-Zero Cross,
ION
S
Instantaneous Turn-On Example:
P
2 Controlled, 1 Linked (A1-A2)
D
Example:
P
Internal Overvoltage Protection.
D53TP
50D-10
D53DP50D
Relay Will Self Trigger Between 900-1200 Vpk. Not Suitable For Capacitive Loads. Example:
H
Heat Trasfer Pad (Attached) Example:
D53TP
D53TP
50D
50DH
GENERAL SPECIFICATION
S
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms Insulation Resistance (Min.) @ 500 Vdc 109Ohm Max. Capacitance Input/Output Ambient Operating Temperature Range
8 pF
-40 to 80ºC
Ambient Storage Temperature Range -40 to 125ºC
MEC
HANICAL
SPECIFICATION
S
Weight: (typical) 10.3 oz. (315g) Encapsulation: Thermally Conductive Epoxy Terminals: Screws and Saddle Clamps Furnished
+
INPUT
---
0.21 (5.3)
2.89
(73.4)
0.79
(20.1)
6-32
TERMINAL
(2 PLACES )
1.18
(30.0)
.79
(20.1)
.94
(24.0)
C
rydom Heat
S
ink
s
offer excellent thermal management and are per fectly matched to the load current ratings of Crydom panel mount relays. Request Crydom’s Heat Sink specification sheet for all the details.
.125 (3.2)
BASE PLATE
THICKNESS
S
c
rew
T
orque
R
6-32 Screws - 10 in. lbs.,
equirement
8-32 and 10-32 Screws - 20in. lbs. (Screws dry without grease.)
s
:
4.09
10-32
TERMINAL
(6 PLACES )
1.875
2.125
(47.6)
(54.0)
.39 REF
(10.0)
P
All dimensions are in inches (millimeters)
(103.8)
A1 B1 C1
A2 B2 C2
1.56
(39.6)
3.62
(91.9)
INPUT
STATUS
LED
.78
(19.8)
1.36
(34.5)
APPR
OVALS
UL E116950 CSA LR81689 VDE 5941 UG
FastFax Document No.161 SERIES53TP
Rev. 111003 PAGE 2 OF 2
60
40
Power Dissipation
20
0
120
90
60
Power Dissipation
30
0
A53DP25D, D53DP25D
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
A53D
P
50D, D53DP50D
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
CURRENT DERATING CURVES
A53
.5ºC/W
1ºC/W
1.5ºC/W
0.25ºC/W
0.5ºC/W
1ºC/W
1.5ºC/W
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
100 105 110 115 120
90 95
100 105
110 115 120
80
60
40
Power Dissipation
20
Base Plate Temp [ºC]
0
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
180 150
120
90
Power Dissipation
60
Base Plate Temp [ºC]
30
0
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
©2003 CRYDOM CORP, Specifications subject to change without
WEB SITE: http://www.crydom.com
TP25D, D53TP
A53TP
25D
0.5ºC/W
1ºC/W
1.5ºC/W
50D, D53TP
.25ºC/W
.5ºC/W
1ºC/W
1.5ºC/W
100
105
110
115 120
50D
90
95 100 105 110
115 120
Base Plate Temp [ºC]
Base Plate Temp [ºC]
notice.