25-50
A
S
m
p
eries
•
240/480 Vac - 3 PHASE
53
T
P
•SCR
•LED S
•
O
utput
tatu
P
rotective
s Indicator
C
over Available
(Part No. KS300)
•
P
anel Mount
• I
ntegrated Overvoltage
P
rotection by Automati
S
elf
T
urn-On
MODEL NUMBERS
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] 48-530 48-530 48-530 48-530
Load Current Range➂ [Arms] .05-25 .05-50 .05-25 .05-50
Transient Overvoltage [Vpk] 1200 1200 1200 1200
Max. Surge Current, (16.6ms) [Apk] 250 625 250 625
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6 1.6
Thermal Resistance Junction to Case (R
Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 260 1620 260 1620
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10 10 10 10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁ 500 500 500 500
Max. Turn-On Time ➃ 1/2 Cycle 1/2 Cycle 10.0 msec 10.0 msec
Max. Turn-Off Time 1/2 Cycle 1/2 Cycle 40.0 msec 40.0 msec
Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
➀
) [˚C/W] 1.02 .63 1.02 .63
θJC
(
S
uffix
D53TP
25D D53TP
c
P)
Three-phase solid state relays switch up
to 530 Vrms directly to loads such as
motors, transformers, heating elements,
etc. Available with either AC or DC
input (coil) control in zero-voltage or
random turn-on switching versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
50D A53TP
25D A53TP
50D
INPUT
Control Voltage Range 3-32 Vdc 90-280 Vrms (60Hz)
Max. Turn-On Voltage 3.0 Vdc 90 Vrms
Min. Turn-Off Voltage 1.0 Vdc 10 Vrms
Nominal Input Impedance 450 Ohms 54.8k Ohms
Typical Input Current 10mA @ 5 Vdc 2.2mA @ 120 Vrms, 4.4mA @ 240 Vrms
GENERAL
➀ All parameters at 25ºC and per section unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃ Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
FastFax Document No.161
SERIES53TP.
Rev. 111003
PAGE 1 OF 2
SPECIFICATIONS
NOTES
➀
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
DC CONTROL
©2003 CRYDOM CORP, Specifications subject to change without notice.
WEB SITE: http://www.crydom.com
AC CONTROL

25-50
A
S
m
p
eries
•
240/480 Vac - 3 PHASE
53
T
P
AVAILABLE OPT
-10
Non-Zero Cross,
ION
S
Instantaneous Turn-On
Example:
P
2 Controlled, 1 Linked (A1-A2)
D
Example:
P
Internal Overvoltage Protection.
D53TP
50D-10
D53DP50D
Relay Will Self Trigger Between
900-1200 Vpk. Not Suitable For
Capacitive Loads.
Example:
H
Heat Trasfer Pad (Attached)
Example:
D53TP
D53TP
50D
50DH
GENERAL SPECIFICATION
S
Dielectric Strength 50/60Hz Input/Output/Base 4000 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance Input/Output
Ambient Operating Temperature Range
8 pF
-40 to 80ºC
Ambient Storage Temperature Range -40 to 125ºC
MEC
HANICAL
SPECIFICATION
S
Weight: (typical) 10.3 oz. (315g)
Encapsulation: Thermally Conductive Epoxy
Terminals: Screws and Saddle Clamps Furnished
+
INPUT
---
0.21
(5.3)
2.89
(73.4)
0.79
(20.1)
6-32
TERMINAL
(2 PLACES )
1.18
(30.0)
.79
(20.1)
.94
(24.0)
C
rydom Heat
S
ink
s
offer excellent
thermal management and are per
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
.125
(3.2)
BASE PLATE
THICKNESS
S
c
rew
T
orque
R
6-32 Screws - 10 in. lbs.,
equirement
8-32 and 10-32 Screws - 20in. lbs.
(Screws dry without grease.)
s
:
4.09
10-32
TERMINAL
(6 PLACES )
1.875
2.125
(47.6)
(54.0)
.39 REF
(10.0)
P
All dimensions are in inches (millimeters)
(103.8)
A1 B1 C1
A2 B2 C2
1.56
(39.6)
3.62
(91.9)
INPUT
STATUS
LED
.78
(19.8)
1.36
(34.5)
APPR
OVALS
UL E116950
CSA LR81689
VDE 5941 UG
FastFax Document No.161
SERIES53TP
Rev. 111003
PAGE 2 OF 2
60
40
Power Dissipation
20
0
120
90
60
Power Dissipation
30
0
A53DP25D, D53DP25D
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
A53D
P
50D, D53DP50D
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
CURRENT DERATING CURVES
A53
.5ºC/W
1ºC/W
1.5ºC/W
0.25ºC/W
0.5ºC/W
1ºC/W
1.5ºC/W
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506
100
105
110
115
120
90
95
100
105
110
115
120
80
60
40
Power Dissipation
20
Base Plate Temp [ºC]
0
510 202515 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
180
150
120
90
Power Dissipation
60
Base Plate Temp [ºC]
30
0
10 20 40 5030 20 40 60 80
Load Current [Arms] Max Ambient Temp. [ºC]
©2003 CRYDOM CORP, Specifications subject to change without
WEB SITE: http://www.crydom.com
TP25D, D53TP
A53TP
25D
0.5ºC/W
1ºC/W
1.5ºC/W
50D, D53TP
.25ºC/W
.5ºC/W
1ºC/W
1.5ºC/W
100
105
110
115
120
50D
90
95
100
105
110
115
120
Base Plate Temp [ºC]
Base Plate Temp [ºC]
notice.