3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
AC Input
40-50 Amp
280/600 VAC
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
100k-cycle UL508 endurance rating
3
1
E
20 - 26 VAC, 50/60 Hz
20 VAC
12 VAC
56 VA @ 24 VAC
6.6 VA @ 24 VAC
1
3
2
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
1
4
Load Current
40: 40 Amps
50: 50 Amps
F
100 - 130 VAC, 50/60 Hz
100 VAC
24 VAC
56 VA @ 120 VAC
6.6 VA @ 120 VAC
28
24 - 280 VAC
0.05 mA @ 240 VAC
40
40 A Resistive
4000 VAC
2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
CONTROL SPECIFICATIONS
Control Voltage Suffix
Coil Voltage Range
Min. Turn-On Voltage
Min. Turn-Off Voltage
Coil Power Consumption, Inrush
Coil Power Consumption, Sealed
Coil Terminals 10 in lb (1.13 Nm) 10 in lb (1.13 Nm) 10 in lb (1.13 Nm)
OUTPUT SPECIFICATIONS
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
Specificationts @ 25°C unless otherwise noted.
2
See Derating Curves for additional operational conditions.
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
4
The RHP includes an overtemperature protection for the Solid-State Module.
Part Number Nomenclature
SERIES
D54012RHP3
Three
Phase
Device
Operating
Voltage VAC
50/60 Hz
12: 120 V 1-phase
24: 240 V 3-phase
or 1-phase
28: 280 V 3-phase
60: 600 V 3-phase
Nominal Coil
/Control Voltage
D5: 5 VDC
D12: 12 VDC
D24: 24 VDC
E: 24 VAC
F: 120 VAC
G: 220 VAC
PATENT
PENDIN
G
208 - 240 VAC, 50/60 Hz
208 VAC
48 VAC
56 VA @ 220 VAC
6.6 VA @ 220 VAC
60
48 - 600 VAC
0.06 mA @ 480 VAC
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
Derating Curves
45
40
35
30
Load Current, Amps rms
25
20
25 35 45 55 65 75
G
CONTROL SPECIFICATIONS
Control Voltage Suffix
Control Voltage Range
Max. Reverse Voltage
Min. Turn-On Voltage
Min. Turn-Off Voltage
Input Current
Input Connector 5.31 in lb (0.6 Nm) 5.31 in lb (0.6 Nm) 5.31 in lb (0.6 Nm)
OUTPUT SPECIFICATIONS
Voltage suffix
Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation
Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time
Max. Turn-Off Time
Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient
temp, 30 operations/min, Rated Vcontrol
Weight (typical)
3RHPXX40XX
Power lead size
AWG # 6
AWG # 8
Safe Operating Area
Ambient Temperature, °C
3 Phase Contactor
DC Input
40-50 Amp
120/240 VAC
Combined SSR and EMR advantages
Lifetime >2 million operations @ full load
No heat sink required
DC logic compatible input
Input status LED indicator
Wire, lug or quick connect termination
DP contactor footprint
CE compliant & UL/cUL recognized
100k-cycle UL508 endurance rating
1
D5
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC
1 VDC
12mA @ 5 VDC
1
100 - 120 VAC
3
0.05 mA @ 120 VAC
2
1
3
4
1
Specificationts @ 25°C unless otherwise noted.
2
See Derating Curves for additional operational conditions.
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
4
The RHP includes an overtemperature protection for the Solid-State Module.
Load Current, Amps rms
40 A Resistive
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
16.6 mS @ 60 Hz / 20 mS @ 50 Hz
32 mS @ 60 Hz / 40 mS @ 50 Hz
55
50
45
40
35
30
25
20
25 35 45 55 65 75
D12
10 - 15 VDC
-15.5 VDC
9.5 VDC
2 VDC
12mA @ 12 VDC
12
40
4000 VAC
2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
3RHPXX50XX
Power lead size
AWG # 6
AWG # 8
Safe Operating Area
Ambient Temperature, °C
PATENT
PENDIN
D24
22 - 27 VDC
-27.5 VDC
9.5 VDC
2 VDC
12mA @ 24 VDC
24
208 - 240 VAC
0.06 mA @ 240 VAC
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
G

Typical Electrical Connection for 3 Phase Applications
(For output voltage options 24, 28, 60)
3 Phase AC
Operating Voltage
5L3
~
~
~
DO NOT apply any AC voltage to contactor coil connections, for DC versions only.
Optional Electrical Connections for Single Phase Applications
(For output voltage options 12, 24, 28, 60)
120/240 VAC
Single Phase
Operating Voltage
VLL
Line
~
Neutral
3L2
1L1
IL1
AC Input/Control Voltage
(E, F, G input versions)
DC Input/Control Voltage
(D5, D12, D24 input versions)
AC Input/Control Voltage
(E, F, G input versions)
5L3=NC
3L2
1L1
DC Input/Control Voltage
(D5, D12, D24 input versions)
+
-
CONTACTOR
HYBRID SOLID STATE
+
-
CONTACTOR
HYBRID SOLID STATE
5
IL3
6T3
4T2
2T1
IL1
6T3=NC
IL1
R1
IL1 ≤ Rated current
3 Phase RHP - Hybrid Solid State Contactors
AC Input/Control Voltage
(E, F, G input versions)
IL3
IL2
IL1
IL2
NC
IL2 ≤ Rated current
IL3 ≤ Rated current
IL2 + IL3 > Rated current
3Ø
Load
Line
5L3
120/240 VAC
Single Phase
Operating Voltage
6
120/240 VAC
Single Phase
Operating Voltage
5
Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX.
6
The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation.
7
In applications switching two single phase loads (R1 and R2) where the combined load current exceeds
the contactor’s rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor
(see above drawing).
Line
Neutral
3L2
~
Neutral
1L1
5L3
3L2
1L1
~
DC Input/Control Voltage
(D5, D12, D24 input versions)
AC Input/Control Voltage
(E, F, G input versions)
7
DC Input/Control Voltage
(D5, D12, D24 input versions)
+
-
CONTACTOR
HYBRID SOLID STATE
IL1 = (IL2 + IL3) ≤ Rated current
+
-
CONTACTOR
HYBRID SOLID STATE
R2
R1
IL3
R2
R1