Crydom RHP User Manual

3 Phase RHP - Hybrid Solid State Contactors
3 Phase Contactor
AC Input
40-50 Amp 280/600 VAC
Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating
3
1
E
20 - 26 VAC, 50/60 Hz
20 VAC 12 VAC
56 VA @ 24 VAC
6.6 VA @ 24 VAC
1
3
2
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
1
4
Load Current 40: 40 Amps 50: 50 Amps
F
100 - 130 VAC, 50/60 Hz
100 VAC
24 VAC
56 VA @ 120 VAC
6.6 VA @ 120 VAC
28
24 - 280 VAC
0.05 mA @ 240 VAC
40
40 A Resistive
4000 VAC
2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
CONTROL SPECIFICATIONS
Control Voltage Suffix Coil Voltage Range Min. Turn-On Voltage Min. Turn-Off Voltage Coil Power Consumption, Inrush Coil Power Consumption, Sealed Coil Terminals 10 in lb (1.13 Nm) 10 in lb (1.13 Nm) 10 in lb (1.13 Nm)
OUTPUT SPECIFICATIONS
Voltage suffix Operating Voltage (50/60Hz)
Maximum Off-State Leakage Current per channel
Load Current suffix
Maximum Load Current per Phase @ 40°C
Power terminals / wire range
Screw torque requirements 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation.
Input/Output to Ground Dielectric Isolation.
Contacts (Double Break )
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient temp, 30 operations/min, Rated Vcontrol
Weight (typical)
1
Specificationts @ 25°C unless otherwise noted.
2
See Derating Curves for additional operational conditions.
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
4
The RHP includes an overtemperature protection for the Solid-State Module.
Part Number Nomenclature
SERIES
D54012RHP3
Three Phase Device
Operating Voltage VAC 50/60 Hz
12: 120 V 1-phase 24: 240 V 3-phase
or 1-phase
28: 280 V 3-phase 60: 600 V 3-phase
Nominal Coil
/Control Voltage
D5: 5 VDC D12: 12 VDC D24: 24 VDC
E: 24 VAC
G: 220 VAC
PATENT PENDIN
G
208 - 240 VAC, 50/60 Hz
208 VAC
48 VAC
56 VA @ 220 VAC
6.6 VA @ 220 VAC
60
48 - 600 VAC
0.06 mA @ 480 VAC
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
Derating Curves
45
40
35
30
Load Current, Amps rms
25
20
25 35 45 55 65 75
G
CONTROL SPECIFICATIONS
Control Voltage Suffix Control Voltage Range Max. Reverse Voltage Min. Turn-On Voltage Min. Turn-Off Voltage Input Current Input Connector 5.31 in lb (0.6 Nm) 5.31 in lb (0.6 Nm) 5.31 in lb (0.6 Nm)
OUTPUT SPECIFICATIONS
Voltage suffix Operating Voltage (50/60Hz) Maximum Off-State Leakage Current per channel
Load Current suffix Maximum Load Current per Phase @ 40°C Power terminals / wire range
Screw torque requirements 18 in lbs (2.1 Nm) 25 in lbs (2.9 Nm)
GENERAL SPECIFICATIONS
Input to Output Dielectric Isolation Input/Output to Ground Dielectric Isolation
Contacts (Double Break)
Ambient Operating Temperature Range
Ambient Storage Temperature Range Max. Turn-On Time Max. Turn-Off Time Maximum Number of Operations per Minute
Lifetime @ Rated Load Current, 40°C ambient temp, 30 operations/min, Rated Vcontrol
Weight (typical)
3RHPXX40XX
Power lead size
AWG # 6
AWG # 8
Safe Operating Area
Ambient Temperature, °C
3 Phase Contactor
DC Input
40-50 Amp 120/240 VAC
Combined SSR and EMR advantages Lifetime >2 million operations @ full load No heat sink required DC logic compatible input Input status LED indicator Wire, lug or quick connect termination DP contactor footprint CE compliant & UL/cUL recognized 100k-cycle UL508 endurance rating
1
D5
4.5 - 5.5 VDC
-5.5 VDC
4.5 VDC 1 VDC
12mA @ 5 VDC
1
100 - 120 VAC
3
0.05 mA @ 120 VAC
2
1
3
4
1
Specificationts @ 25°C unless otherwise noted.
2
See Derating Curves for additional operational conditions.
3
The RHP includes a Solid-State Relay. Therefore, the output is never completely open.
4
The RHP includes an overtemperature protection for the Solid-State Module.
Load Current, Amps rms
40 A Resistive
Dual quick connect and Binder
head screws / AWG#14 - AWG#8
16.6 mS @ 60 Hz / 20 mS @ 50 Hz 32 mS @ 60 Hz / 40 mS @ 50 Hz
55
50
45
40
35
30
25
20
25 35 45 55 65 75
D12
10 - 15 VDC
-15.5 VDC
9.5 VDC 2 VDC
12mA @ 12 VDC
12
40
4000 VAC 2500 VAC
Three Normally Open
-20°C to 75°C
-40°C to 100°C
30 operations per min
> 2 Million operations
540 grs (1.19 lb)
3RHPXX50XX
Power lead size
AWG # 6
AWG # 8
Safe Operating Area
Ambient Temperature, °C
PATENT PENDIN
D24
22 - 27 VDC
-27.5 VDC
9.5 VDC 2 VDC
12mA @ 24 VDC
24
208 - 240 VAC
0.06 mA @ 240 VAC
50
50 A Resistive
Dual quick connect and Box
lugs / AWG#14 - AWG#6
G
Typical Electrical Connection for 3 Phase Applications
(For output voltage options 24, 28, 60)
3 Phase AC
Operating Voltage
5L3
~ ~ ~
DO NOT apply any AC voltage to contactor coil connections, for DC versions only.
Optional Electrical Connections for Single Phase Applications
(For output voltage options 12, 24, 28, 60)
120/240 VAC
Single Phase
Operating Voltage
VLL
Line
~
Neutral
3L2
1L1
IL1
AC Input/Control Voltage (E, F, G input versions)
DC Input/Control Voltage
(D5, D12, D24 input versions)
AC Input/Control Voltage
(E, F, G input versions)
5L3=NC
3L2
1L1
DC Input/Control Voltage
(D5, D12, D24 input versions)
+
-
CONTACTOR
HYBRID SOLID STATE
+
-
CONTACTOR
HYBRID SOLID STATE
5
IL3
6T3
4T2
2T1
IL1
6T3=NC
IL1
R1
IL1 ≤ Rated current
3 Phase RHP - Hybrid Solid State Contactors
AC Input/Control Voltage
(E, F, G input versions)
IL3
IL2
IL1
IL2
NC
IL2 ≤ Rated current IL3 ≤ Rated current
IL2 + IL3 > Rated current
Load
Line
5L3
120/240 VAC
Single Phase
Operating Voltage
6
120/240 VAC
Single Phase
Operating Voltage
5
Match VLL to voltage suffixes 28 & 60 for options E, F & G and 12 & 24 for options DX.
6
The single phase supply voltage must be wired to terminal 1L1 and 3L2 for proper single phase operation.
7
In applications switching two single phase loads (R1 and R2) where the combined load current exceeds the contactor’s rating (40 or 50 Amps) the return/neutral lead must not be wired through the contactor (see above drawing).
Line
Neutral
3L2
~
Neutral
1L1
5L3
3L2
1L1
~
DC Input/Control Voltage
(D5, D12, D24 input versions)
AC Input/Control Voltage
(E, F, G input versions)
7
DC Input/Control Voltage
(D5, D12, D24 input versions)
+
-
CONTACTOR
HYBRID SOLID STATE
IL1 = (IL2 + IL3) ≤ Rated current
+
-
CONTACTOR
HYBRID SOLID STATE
R2
R1
IL3
R2
R1