Crydom EZ Series Data Sheet

5-18
A
S
eries
m
p
120/240, 480 Vac • AC OUTPU
E
Z
T
Low Leakage
Quick Connect Terminals
SCR Output
24V Control Available
(EZE Models)
The Series EZ SPST-NO AC output relays offer a low profile package with the convenience of quick con-
AC CONTROL (120Vac)
MODEL NUMBERS
DC CONTROL (5Vdc) EZ240D12 EZ240D18 EZ480D12 EZ480D18
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms] 24-280 24-280 48-660 48-660 Max. Load Current ➃ [Arms] 12 18 12 18 Min. Load Current, [mArms] 150 150 150 150 Transient Overvoltage [Vpk] Max. Surge Current, (16.6ms) [Apk] Max. On-State Voltage Drop @ Rated Current [Vpk] 1.5 1.5 1.5 1.5 Thermal Resistance Junction to Case (R Maximum I2 t for Fusing, (8.3 msec.) [A2sec] 95 170 95 170
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] 500 500 500 500 Max. Turn-On Time 1/2 Cycle (DC Input), 10.0 msec (AC Input) Max. Turn-Off Time 1/2 Cycle (DC Input), 40.0 msec (AC Input) Power Factor (Min.) with Max. Load 0.5 0.5 0.5 0.5
(24Vac)
EZ240D5
(24Vdc) EZE240D12 EZE240D18 EZE480D12 EZE480D18
24-280
5 150 600
40
1.5
) [˚C/W] 2.0 1.1 2.0 1.1
θJC
2.0 95
0.1
500
0.5
EZ240A12 EZ240A18 EZ480A12 EZ480A18
EZE240A12 EZE240A18 EZE480A12 EZE480A18
600 600 1200 1200 150 200 150 200
0.1 0.1 0.1 0.1
nect terminals. The Series EZ is the preferred choice for replacement of 120V and 240V Electro-mechanical relays. Output consists of an SCR switch and is available in Zero-Cross and Random Turn-On (Phase Controlable) versions.
Manufactured in Crydoms ISO 9001 Certified facility for optimum product performance and reliability.
INPUT SPECIFICATIONS DC CONTROL
Nominal Voltage
MODEL NUMBERS EZE240D18
Control Voltage Range Max. Turn-On Voltage Min. Turn-Off Voltage Nominal Input Impedance Typical Input Current @ Nominal Voltage
GENERAL NOTES
5Vdc
EZ240D5
4-15 Vdc
4.0 Vdc
1.0 Vdc
300 Ohms
13 mAdc
5Vdc
EZ240D12 EZ240D18
3-15 Vdc
3.0 Vdc
1.0 Vdc
300 Ohms
15 mAdc
5Vdc 24Vdc
EZ480D12 EZE480D12 EZ480D18 EZE480D18
4-15 Vdc 15-32 Vdc
4.0 Vdc 15.0 Vdc
1.0 Vdc 1.0 Vdc
240 Ohms 1500 Ohms
15 mAdc 15 mAdc
All parameters at 25˚ C unless otherwise specified.Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1240V, DC control models only, all others 2500Vrms.Heat sinking required, for derating curves see page 2.Off-State leakage for snubbered
version (suffix S) is 10.0 mArms.
Turn-on time for random turn-on versions
is 0.1 msec (DC Control Models).
FastFax Document No.160 SERIES EZ. Rev. 111203 PAGE 1 OF 2
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
AC CONTROL
120Vac 24Vac
EZE240D12
© 2003 CRYDOM CORP, Specifications subject to change without notice.
WEB SITE: http://www.crydom.com
EZ240A12 EZE240A12 EZ240A18 EZE240A18 EZ480A12 EZE480A12 EZ480A18
90-140 Vrms
90.0 Vrms
10.0 Vrms
10.6k Ohms 10 mArms 10 mArms
EZE480A18
18-36 Vrms
18.0 Vrms
2.0 Vrms
1.8k Ohms
S
5-18
A
eries
m
p
120/240, 480 Vac • AC OUTPU
E
GENERAL SPECIFICATIONS
Dielectric Strength Insulation Resistance (Min.) @ 500 Vdc 10 Max. Capacitance Input/Output Ambient Operating Temperature Range
50/60Hz Input/Output/Base 4000 Vrms*
9
Ohm
8 pF
-40 to 80˚C
Ambient Storage Temperature Range -40 to 125˚C
MECHANICAL SPECIFICATIONS
Weight: (typical)
1.5 oz. (43g) Encapsulation: Thermally Conductive Epoxy Terminals: .25 Inch Faston
Z
T
AVAILABLE OPTIONS S Internal Snubber
Example: EZ240D12S
R Random Turn-On Switching
Example: EZ240D12R, EZ240D12RS
EZ240D5R
Crydom Heat Sinks offer excellent ther­mal management and are perfectly matched to the load current ratings of Crydom panel mount relays. Request Crydoms Heat Sink specification sheet for all the details.
6 5 4 3 2
Power Dissipation
1
23 510420406080
1
Load Current [Arms] Max Ambient Temp. [˚C]
5A
10˚C/W
NO HEATSINK
5˚C/W
110
115
Base Plate Temp [˚C]
120
2.63
(66.8)
2.24
(56.9)
1.00
(25.4)
FASTON TERMINAL .250 X .032 4 PLCS.
.12
(3.0)
1
OUTPUT
3+ 4
INPUT
1.73
(43.9)
2
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
15
10
5
Power Dissipation [W]
0
24 810126 20406080
Load Current [Arms] Max Ambient Temp. [˚C]
12A
NO HEATSINK
6˚C/W
4˚C/W
2˚C/W
112
116
120
124
(12.4)
(10.2)
Base Plate Temp [˚C]
.197 DIA. (2 PLCS)
.49
.40
(38.1)
(24.1)
*240V, DC Control Models Only.
1.50
.95
PIN 1: AC LOAD PIN 2: AC LOAD PIN 3: +DC CONTROL PIN 4: ---DC CONTROL
18
12
6
Power Dissipation [W]
0
3 6 12 15 18920406080
Load Current [Arms] Max Ambient Temp. [˚C]
18A
5˚C/W
NO HEATSINK
2˚C/W
112
116
120
Base Plate Temp [˚C]
124
APPROVALS
UL E116950 CSA LR81689 VDE 10139 UG (240V DC Control Only)
FastFax Document No.160 SERIES EZ Rev. 111203 PAGE 2 OF 2
© 2003 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact: USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540 Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com UK: +44 (0)1202 365070 FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com. GERMANY: +49 (0)180 3000 506
WEB SITE: http://www.crydom.com
Loading...