Required for valid part number
For options only and not required for valid part number
OUTPUT SPECIFICATIONS
Description10 A
Operating Voltage (47-63Hz) [Vrms]24-280
Maximum Load Current [Adc]
Minimum Load Current [mArms]150
Transient Overvoltage [Vpk]
Maximum Surge Current (50/60Hz, 1 Cycle) [Apk] 145/150
Maximum I²t for Fusing (50/60Hz 1/2 cycle) [A² sec]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Voltage Drop @ Rated Current [Volts]
Minimum Power Factor (at Maximum Load) (1)
Switching Type
Blank: Zero Voltage Turn-On
R: Instantaneous Turn-On
5 A
24-280
5
150
600
115/120
65/60
500
0.1
5.5
1.3
0.7
Control Voltage
05: 4-8 VDC
12: 10-14 VDC
24: 21-27 VDC
05R
NPEL30240A
Termination
Blank: Standard Quick Connect
N: 90º bent Quick Connect
(30 Amps only)
10
600
100/95
500
0.1
3.0
1.3
0.7
Overvoltage Protection
Blank: Not included
P: Included (Only for 30 Amps,
Zero Voltage models ) (1)(2)
20 A
24-280
20
250
600
240/250
285/260
500
0.1
1.7
1.3
0.7
30 A
24-280
30
250
600
260/280
338/326
500
0.1
0.9
1.3
0.7
INPUT SPECIFICATIONS
DescriptionEL240Axx-12
Control Voltage Range10-14 VDC
Minimum Turn-On Voltage
Must Turn-Off Voltage
Minimum Input Current
Maximum Input Current 17.50 mA
Maximum Turn-On Time [msec] (5)
Maximum Turn-Off Time [msec]
(3)
EL240Axx-05
4-8 VDC
4 VDC
1 VDC
6 mA
21 mA
1/2 Cycle
1/2 Cycle
10 VDC
1 VDC
10 mA
1/2 Cycle
1/2 Cycle
EL240Axx-24
21-27 VDC
21 VDC
1 VDC
8 mA
19 mA
1/2 Cycle
1/2 Cycle
FDE-07-01 REV. A
Panel Mount
Datasheet
GENERAL SPECIFICATIONS
(2)
ParametersDescription
Dielectric Strength, Input to Output (50/60Hz)3750 Vrms
Dielectric Strength, Output to Baseplate (50/60Hz)
Maximum Capacitance, Input/Output8 pF
Ambient Operating Temperature Range-30 to 80°C
Ambient Storage Temperature Range-30 to 125 °C
Weight (typical)0.5 oz (14.4 g)
Terminals3/16”x 0.032” input, 1/4”x 0.032” output QC
SSR Mounting Screw Torque Range9.0-10.0 in-lb (1.0-1.13 Nm)
LED Input Status IndicatorGreen
Humidity per IEC60068-2-7893% non-condensing
2500 Vrms
THERMAL DERATE INFORMATION
EL240A5x-xxx
5
4
3
2
1
Load Current (Amps)
0
20304050607080
8.0ºC/W4.0ºC/W
10
8
6
4
2
Load Current (Amps)
0
0
20304050607080
EL240A10x-xxx
Ambient Temperature (ºC)
EL240A20x-xxx
20
16
12
8
4
Load Current (Amps)
0
0
1.5ºC/W
20304050607080
Ambient Temperature (ºC)
2.0ºC/W3.0ºC/W
EQUIVALENT CIRCUIT BLOCK
4
-
DC
+DC 3
Trigger
Circuit
Ambient Temperature (ºC)
EL240A30x-xxx
30
24
18
12
Load Current (Amps)
(6)
1.5ºC/W
6
0
0
20304050607080
Ambient Temperature (ºC)
1
2
2.0ºC/W3.0ºC/W
LOAD
LOAD
AC
A
B
AC
OUTPUT
LOAD CAN BE WIRED IN POSITION A or B
WIRING DIAGRAMS
Panel Mount
Datasheet
AC
V
Load
1 2 ( )
( )
1
2
3
4
4 (–)3 (+)
AC
V
Load
1 2 ( )
( )
1
2
3
4
4 (–)3 (+)
MOUNTING INSTRUCTIONS
Choose one of the two mounting options and follow the instructions.
Mounting on Heat Sinks
■
Select adequate heat sink. (Please refer to thermal derating curves for the specific model)
■
Be sure that thermal pad is pre-installed before installing over the heat sink.
■
EL mounting slots have a diameter of 0.16 in (4.0 mm). Two screws are needed (not included) to mount the EL onto heat sink (See fig. 1).
Recommended screw size is 8-32 (UNC standard) or M4 (metric).
■
Before applying full torque tighten down both screws until they contact the baseplate. Then, tighten them to 9.0-10.0 in-lb (1.0-1.13 Nm).
■
For optimal thermal performance heat sink fins should be oriented vertically to promote natural convection airflow.
Mounting on Panels
■
Locate the panel section on which the EL will be mounted. Panel mount surface must provide adequate heat sinking capability, uncoated, clean,
flat (0.004 in/in recommended) and preferably aluminum.
■
Be sure that thermal pad is pre-installed before install over the heatsink.
■
EL mounting slots have a diameter of 0.16 in (4.0 mm). Two screws are needed (not included) to mount the EL onto panel. Choose screw length
considering the mounting surface hole depth and that the SSR flange thickness is 0.125 in (3.2 mm).
■
Before applying full torque tighten down both screws until they contact the baseplate. Then, tighten them to 10 in-lb (1.13 Nm).
Transient Protection
Transients are common on AC power lines, and in extreme cases, may pose a risk for the proper operation and reliability of the SSR and its load.
The load which the SSR controls may also generate transients itself. Therefore, inclusion of transient protection for the SSR is highly recommended.
Internal transient protection is standard in certain Crydom SSR models, and optionally available in others. The user may also install transient
protection external to the SSR for additional protection. Contact Crydom technical support for additional information on use of transient protection
for AC output SSRs.
Important Considerations
Be sure to use input and output voltages within operating ranges. LED indicates only input status. It does not represent output status.
fig. 1 EL mounted
on heat sink
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
0.187x0.0320.250x0.032
Panel Mount
Datasheet
Standard Quick Connect terminals
0.15
[3.8]
0.18
[4.5]
0.46
[11.7]
1.39
[35.3]
1.44
[36.6]
0.48
[12.1]
1.00
[25.4]
0.56
[14.3]
90° bent Quick Connect terminals
0.74
[18.8]
0.56
[14.3]
0.83
[21.1]
0.83
[21.1]
0.60
[15.2]
-4
+3
Pinout
Terminal 1: AC load
Terminal 2: AC load
Terminal 3: +DC control
Terminal 4: -DC control
0.61
[16.8]
0.84
[22.3]
1.18
[30.0]
1
2
0.16
[4.1]
0.16
[4.1]
0.48
[12.1]
0.18
[4.5]
1.44
[36.6]
AGENCY APPROVALS, CONFORMANCES AND EMC
E116950
Certification in accordance with:
United States Standard for Industrial Control Equipment - UL 508 and
Canadian Standard Association for Industrial Control Equipment – C22.2 No. 14.
TUV SUD according to IEC 60335-1 and EN 62314:2006
Vibration and Shock Resistance:
IEC 61373 : Category 1, Class B.
(Except P option)
.05
[1.2]
0.84
[21.3]
1.18
[30.0]
Datasheet
Electromagnetic Compatibility
Generic
Standard
IEC 61000-6-2
Immunity for
Industrial
Environments
Inmunity TestsTest Specification
Electrostatic Discharge
IEC 61000-4-2
Fast transients (burst)
IEC 61000-4-4
Surge
IEC 61000-4-5
8kV air discharge
6kV contact discharge
Output 5kHz
Input 5kHz
1kV Line to Line
Output
2kV Line to Earth
Level
GENERAL NOTES
(1) For option P minimum power factor (at maximum load) is 0.9
(2) In models with built-in overvoltage protection ("P" option), the output will self trigger between 450-600Vpk, not suitable for capacitive loads.
(3) All parameters at 25°C unless otherwise specified.
(4) When mounted to the proper size heat sink (see derating curves).
(5) Turn-on time for Instantaneous turn-on versions is 0.02 msec
(6) Elective Overvoltage Protection, “P” option.
Performance
Criterion A
Criterion A
Criterion B
Criterion B
Criterion B
Criterion B
Panel Mount
Rev. 102017
ECN 20340