Crydom DRA1 MP Series Data Sheet

DRA1 MP Series
• 10mm Single Channel DIN Rail Mount SSR Assembly
• AC Ratings up to 280 VAC and 4 Amps
• DC Ratings 60 VDC and 3 Amps
• N.O. AC or DC output, N.C. DC Output (-B)
• 3-32VDC control
• Cage style screw terminals for easy connection
PRODUCT SELECTION
Description 3 A3 A4 A
3-32 VDC Control DRA1-MP120D3 DRA1-MP240D3 DRA1-MP240D4 3-32 VDC Control DRA1-MPDCD3 DRA1-MPDCD3-B
AC OUTPUT SPECIFICATIONS (1)
Description DRA1-MP120D3 DRA1-MP240D3 DRA1-MP240D4
Operating Voltage [VAC] 12-140 24-280 24-280 Transient Overvoltage [Vpk] 400 600 600 Maximum Load Current [Arms] (2) 3 3 4 Minimum Load Current [Arms] 0.02 0.02 0.02 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 5 5 5 Minimum off-state dv/dt @ maximum rated voltage [V/µsec] (3) 200 200 200 Maximum 1 Cycle Surge Current (50/60 Hz) [Apk] 86/90 86/90 125/130 Maximum I²t for fusing (50/60 Hz, 1/2 cycle) [A² sec] 39/36 39/36 78/72 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6
DC OUTPUT SPECIFICATIONS (1)
Description DRA1-MPDCD3 DRA1-MPDCD3-B
Operating Voltage [VDC] 3-60 3-60 Maximum Load Current [Adc] 3 3 Minimum Load Current [Adc] 0.02 0.02 Maximum Surge Current [Adc] 5 5 Maximum On-State Voltage Drop @ Rated Current [Vdc] 1.5 1.5
INPUT SPECIFICATIONS (1)
Description DRA1-MPxxxDx DRA1-MPDCD3 DRA1-MPDCD3-B
Control Voltage Range 3-32 VDC 3-32 VDC 3-32 VDC Must Turn On Voltage 3.0 VDC 3.0 VDC 1.0 VDC Must Turn Off Voltage 1 .0 VDC 1 .0 VDC 3 .0 VDC Typycal Input Current 2.6 mAdc 2.6 mAdc 2.6 mAdc Nominal Input Impedance 1500 Ohm 1500 Ohm 1500 Ohm Maximum Turn-On Time [msec] 8.33 0.10 0.10 Maximum Turn-Off Time [msec] 8.33 0.10 0.10
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 VRMS Minimum Insulation Resistance (@ 500 VDC)
Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80°C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 0.08 lb (36.4g) Encapsulation Themally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) See derating chart on page 3
3) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
109 Ohms