Crydom CW24 Series Data Sheet

Panel Mount
Datasheet
CW24 Series
Ratings from 10A to 125A @ 24-280VAC
SCR Output for heavy industrial loads
LED Status Indicator
UL/CSA/TUV Approved, CE Compliant to EN60950-1
Improved SEMS screw and washer
Redesigned housing with anti-rotation barriers
For Generation 3 datasheet click here
PRODUCT SELECTION
Control Voltage 10A 25A 50A 90A 125A
3-32 VDC CWD2410 CWD2425 CWD2450 CWD2490 CWD24125 90-280 VAC CWA2410 CWA2425 CWA2450 CWA2490 CWA24125 18-36 VAC CWA2410E CWA2425E CWA2450E CWA2490E CWA24125E 20-48 VDC/20-280 VAC CWU2410 CWU2425 CWU2450 CWU2490 CWU24125
AC/DC control
EMC Compliant to Level 3
Epoxy Free Design
Removable IP20 touch-safe cover
DBC substrate for superior thermal
performance
AVAILABLE OPTIONS
Series
Required for valid part number For options only and not required for valid part number Not all part number combinations are available.
*
Contact Crydom Technical Support for information on the availability of a specific part number.
OUTPUT SPECIFICATIONS
Control Voltage D: 3-32 VDC U: 20-48 VDC or 20-280 VAC A: 90-280 VAC AxxxxE: 18-36 VAC
(2)
Operating Voltage 24: 24-280 VAC
1024CW D E
Rated Load Current 10: 10 Amps 25: 25 Amps 50: 50 Amps 90: 90 Amps 125: 125 Amps
Thermal Pad Blank: Not Included H: Included
Overvoltage Protection Blank: Not Included P: Included (1)
-10P H
Switching Type Blank: Zero Voltage Turn-On
-10: Instantaneous Turn-On
Description 90A25A
Operating Voltage (47-440Hz) [Vrms] 24-280 24-280 Transient Voltage [Vpk] 600 600 Maximum Off-State Leakage Current @ Rated Voltage [mArms] 1 1 Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec) 500 500 Maximum Load Current [Arms] Minimum Load Current [mArms] 150 250 Maximum 1 Cycle Surge Current (50/60Hz) [Apk] 570/600 1290/1350 Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.3 1.3 Thermal Resistance Junction to Case (Rjc) [°C/W] 0.3 0.16 Maximum 1/2 Cycle I² t for Fusing (50/60Hz) [A² sec] 1620/1500 8320/7560 Minimum Power Factor (at Maximum load) (1) 0.5 0.5 HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 120 VAC 1 (0.74) 3 (2.24) HP Rating UL 508/IEC60947 [-10 Option][HP (KW)]: 240 VAC 3 (2.2) 7.5 (5.6) HP Rating UL 508/IEC60947 [HP (KW)]: 120 VAC 0.75 (0.56) 2 (1.5) HP Rating UL 508/IEC60947 [HP (KW)]: 240 VAC 2 (1.5) 5 (3.73)
INPUT SPECIFICATIONS
(3) 25 90
(2)
Description CWD
Control Voltage Range 3-32 VDC Maximum Reverse Voltage -32 VDC Minimum Turn-On Voltage 3 VDC (5) Must Turn-Off Voltage 1 VDC Minimum Input Current (for on-state) 10 mA Maximum Input Current 15 mA Nominal Input Impedance Current Regulated Maximum Turn-On Time [msec] 1/2 Cycle (6) Maximum Turn-Off Time [msec] 1/2 Cycle
24-280 24-280 24-280
600 600 600
1 1 1
500 500 500
10 50 125
150 150 250
380/400 810/850 1900/2000
1.3 1.3 1.25
0.35 0.2 0.11
720/660 3280/3000 18000/16600
0.5 0.5 0.5
0.5 (0.37) 2 (1.5) 5 (3.37)
1.5 (1.1) 5 (3.73) 10 (7.5)
0.5 (0.37) 1 (0.74) 3 (2.24)
1.5 (1.1) 3 (2.2) 7.5 (5.6)
CWA
90-280 VAC (4)
­90 VAC 10 VAC
6 mA
10 mA
Current Regulated
20 30
CWAxxxxE
18-36 VAC
-
18 VAC
4 VAC
13 mA
15 mA
Current Regulated
20 30
125A50A10A
CWU
20-48 VDC/ 20-280VAC
-
19 VDC/VAC
5 VDC/VAC
7/13 mA
11/9 mA
Current Regulated
20 30
Panel Mount
Datasheet
GENERAL SPECIFICATIONS
(1)
ParametersDescription
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms Minimum Insulation Resistance (@ 500 VDC)
109 Ohms
Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range (7) -40 to 80 °C Ambient Storage Temperature Range -40 to 125 °C Weight (typical) 2.88 oz (81.53 g) Housing Material UL94 V-0 Baseplate Material Aluminum Input Terminal Screw Torque Range (in-lb/Nm) 13-15 /1.5-1.7 Load Terminal Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 SSR Mounting Screw Torque Range (in-lb/Nm) 18-20 / 2-2.2 Input/Output Terminal Screw Thread Size #6-32 UNC / #8-32 UNC Humidity per IEC60068-2-78 93% non-condensing LED Input Status Indicator Green
MTBF (Mean Time Between Failures) at 40°C ambient temperature (8) MTBF (Mean Time Between Failures) at 60°C ambient temperature (8)
11,641,553 hours (1,328 years)
7,210,376 hours (823 years)
WIRING DIAGRAM
AC
V
(9)
Load
1 ( ) 2 ( )
2
OUTPUT
1
SOLI D S T AT E R ELA Y
4
INPUT
3
Terminals
Input
Output
Recommended Wire Sizes
Wire Size
(Solid / Stranded)
24 AWG (0.2 mm
2 x 12 AWG (3.3 mm
20 AWG (0.5 mm
2 x 10 AWG (5.3 mm
2
2
2 x 8 AWG (8.4 mm
4 (– / ) 3 (+ / )
EQUIVALENT CIRCUIT BLOCK DIAGRAMS
CWD Series DC Control
4
-
DC
Trigger Circuit
Trigger Circuit
(10)
AC/-DC
AC/+DC
+DC
INPUT
3
4
INPUT
3
Current
Limiter
AC/DC
Converter
CWA/CWU Series AC Control
Current
Limiter
) / 0.2 [minimum]
2
) / 3.3 [maximum]
) / 0.518 [minimum]
2
) / 5.3
2
) / 8.4 [maximum]
(10)
1
OUTPUT
2
1
AC
OUTPUT
2
AC
AC
AC
Wire Pull-Out
Strength (lb)[N]
10 [44.5]
90 [400]
30 [133]
110 [490]
90 [400]
14
12
10
8
6
4
Input Current (mA)
2
0
0 5 10 15 20 25 30 35
7
6
5
4
3
2
Input Current (mA)
1
0
0 50 100 150 200 250 300
16
14
12
10
8
6
4
Input Current (mA)
2
0
0 5 10 15 20 25 30 35
Input Current vs Input Voltage
Standard Regulated DC Input
DC Input Voltage
Input Current vs Input Voltage
Standard Regulated AC Input
AC Input Voltage
Input Current vs Input Voltage
Regulated AC Input Option “E”
AC Input Voltage
Panel Mount
Datasheet
MECHANICAL SPECIFICATIONS
Tolerances: ±0.02 in / 0.5 mm All dimensions are in: inches [millimeters]
(1)
Screw Termination
1.88
[47.6]
1.1
[27.9]
0.49
[12.4]
OUTPUT
1
S OLID S T A T E R ELA Y
4
INPUT
1.0
1.0
[25.4]
[25.4]
1.75
1.75
[44.5]
[44.5]
Mounting Hole/Slot
0.19 [4.9] DIA.
2
1.7
[43.2]
3
0.89
[22.6]
2.25
[57.3]
1.88
[47.6]
1.7
[43.2]
GENERAL NOTES
(1)
Output will self trigger between 900-1200Vpk. Min. power factor 0.7 or higher, not suitable for capacitive loads.
(2) All parameters at 25°C unless otherwise specified. (3) Heat sinking required, see derating curves (4) For ambient temperature above 40°C the maximum control voltage must not exceed 250VAC. (5) Increase minimum voltage by 1V for operations from -20 to -40°C. (6) Turn-on time for Instantaneous turn-on versions is 0.1 msec and 7msec for CWU models. (7) AC input models operating range is -20 to 80 °C. (8)
All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report).
(9)
Load can be wired to either SSR output terminal 1 or 2
(10)
Select P option for overvoltage protection.
(11)
For single surge pulse Tc=25°C; Tj=125°C. For AC Output SSRs, AC Rms value of surge current equals the peak value divided by
For additional information or specific questions, contact Crydom Technical Support.
.
Screw Termination, IP20
1.1
[27.9]
0.49
[12.4]
1.0
1.0
[25.4]
[25.4]
1.75
1.75
[44.5]
[44.5]
2 (1.414).
Mounting Hole/Slot
0.19 [4.9] DIA.
2.32
[58.8]
2.25
[57.3]
1.22
[30.9]
Loading...