2
INSTALLATION
THE INSTALLATION OF THIS APPLIANCE MUST BE IN ACCORDANCE WITH:
1) All applicable local codes, or in the absence of local codes;
2) i) Canada: must conform to current National Standard CAN/CGA B149.1&.2 -
natural gas/propane installation code.
ii) U.S.A.: must conform to national Fuel Gas Code, ANSI Z223.1, 1988 or latest
edition.
WARNING!
DO NOT operate this appliance under overhead, unprotected construction. This
appliance shall be used only in a well ventilated space and shall not be used in a building,
garage, or any other enclosed area.
Minimum clearance to adjacent combustible materials:
• 12 inches from side(s)
• 24 inches from back (See Fig. 1 pg. 3.)
• This appliance is suitable for use on combustible floors.
• Always level your MCB front to back & side to side.
• Always keep the area surrounding your charbroiler clear of all combustible materials,
gasoline, or other flammable liquids.
• Use your charbroiler OUTDOORS in a well-ventilated space, preferably 10 ft. from
dwellings or outbuildings.
• Casters must be locked when appliance is in operation.
CAUTION: FOR FIXED FUEL SUPPLY SYSTEMS
RE: PRESSURE TESTS
1. The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 psi. (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing it’s
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi. (3.45kPa).
CROWN VERITY INC., 37 ADAMS BLVD., BRANTFORD, ON. CAN. N3S 7V8
TEL: (519) 751-1800 FAX: (519) 751-1802
www.crownverity.com
Email: info@crownverity.com