INSTALLATION
THE INSTALLATION OF THIS APPLIANCE MUST BE IN ACCORDANCE WITH:
1) All applicable local codes, or in the absence of local codes;
2) i) Canada: must conform to current National Standard CAN/CGA B149.1&.2 -
natural gas/propane installation code.
ii) U.S.A.: must conform to national Fuel Gas Code, ANSI Z223.1, 1988 or latest
edition.
WARNING!
DO NOT operate this appliance under over head, unprotected construction. This
appliance shall be used only in a well ventilated space and shall not be used in a building,
garage, or any other enclosed area.
Minimum clearance to adjacent combustible materials:
• 12 inches from side(s)
• 24 inches from back (See Fig. 1 pg. 3.)
• This appliance is suitable for use on combustible floors.
• Always level your MCB front to back & side to side.
• Always keep the area surrounding your charbroiler clear of all combustible materials,
gasoline, or other flammable liquids.
• Use your charbroiler OUTDOORS in a well-ventilated space, preferably 10 ft. from
dwellings or outbuildings.
• Casters must be locked when appliance is in operation.
CAUTION: FOR FIXED FUEL SUPPLY SYSTEMS
RE: PRESSURE TESTS
1. The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures in
excess of 1/2 psi. (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing it’s
individual manual shut-off valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 psi. (3.45kPa).