Crown Steam GMTS-40 Operator’s Manual

INSTALLATION & OPERATION
MANUAL
Gas Modular Skillets
GMTS-30 GMTS-40 GMTS-60
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read
the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
MANUAL 10094R2
WARNING
CROWN FOOD SERVICE EQUIPMENT
Division of Middleby Canada Company Inc.
70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
Telephone: 919-762-1000
Printed in Canada
www.crownsteamgroup.com
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
1.0 IMPORTANT NOTES FOR INSTALLATION AND OPERATION
It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should be retained for future reference.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
PURCHASER: Instructions to be followed in the event that the operator of this appliance smells gas must be posted in a prominent location. This information shall be obtained by consulting the local gas supplier.
Do not attempt to operate this unit in the event of power failure.
The appliance area must be kept free and clear of combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for safe and proper operation.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
Part No. 10094R2 2 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
TABLE OF CONTENTS
DESCRIPTION PAGE
1.0 Important Notes for Installation and Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.0 Service Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.0 Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.0 Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.0 Cleaning Instructions .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
6.0 Cooking Temperatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
7.0 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
8.0 Troubleshooting .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Material Safety Data Sheets .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Part No. 10094R2 3 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
2. SERVICE CONNECTIONS
Part No. 10094R2 4 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
Part No. 10094R2 5 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
3.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be damaged, save the packaging material and contact the carrier within 15 days of delivery.
Before installing, verify that the electrical service agrees with the specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do not agree, contact your dealer or Crown Food Service Equipment Ltd.
LOCATION
The installation location must allow adequate clearances for servicing and proper operation.
An exhaust system and ventilation hood should be located directly above the appliance to exhaust combustion gases generated by the unit.
Appliance is intended for use on noncombustible floors. Minimum clearance from combustible and noncombustible floor construction, 3" (76 mm) on sides and 6" (152 mm) from back.
INSTALLATION CODES AND STANDARDS
Installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psi (3.5 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psi (3.5 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.
ANSI/NFPA 96 - (latest edition), “Standard for Ventilation and Fire Protection of Commercial Cooking Operations,” available from the National Fire Protection Association, Batterymarch Park, Quincy, MA, USA, 02269.
Part No. 10094R2 6 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
3.0 INSTALLATION INSTRUCTIONS (Continued)
LEVELLING AND ANCHORING TILTING BRAISING PAN
1. Place tilting braising pan in the installation position.
2. Place a carpenter’s level on top of the braising pan and turn the adjustable feet to level braising pan side-to-side and front-to-back.
3. Mark hole locations on the floor through the anchoring holes provided in the rear flanged adjustable feet.
4. Remove tilting braising pan from installation position and drill holes in locations marked on the floor. (See installation diagram on page 4.) Insert proper anchoring devices (not supplied).
5. Place tilting braising pan back in the installation position.
6. Place carpenter’s level on top of braising pan and re-level side-to-side and front to back.
7. Bolt and anchor tilting braising pan securely to the floor.
8. Seal bolts and flanged feet with silastic or equivalent compound.
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.
Connect gas supply to the appliance. The gas supply line must be at least equivalent of 3/4" iron pipe with an incoming pressure of 7" - 14" W.C. (Water Column) for natural gas or 11" - 14" W.C. (Water Column) for propane gas. Make sure the pipes are clean and free of obstructions, dirt and piping compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of the tilting braising pan.
Natural gas and propane gas skillets are equipped with fixed orifices and no adjustment is necessary. Gas burner manifold is set at 3.5" W.C. (Water Column) for natural gas, and 10" W.C. (Water Column) for propane gas.
Part No. 10094R2 7 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
GAS CONNECTIONS (Continued)
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
WARNING: Never use an open flame to check for gas leaks. Check all connections for leaks using soapy water before use.
NOTICE: If this equipment is being installed at over 2,000 feet altitude and was not so specified on order, contact service department. Failure to install with proper orifice sizing may void the warranty.
CAUTION: The pipe thread compound used when installing pipes must be a type that is resistant to the action of liquified petroleum or propane gases.
Part No. 10094R2 8 2019-01-16
INSTALLATION AND OPERATION MANUAL, GAS SKILLETS, MODELS GMTS-(30, 40, 60)
INSTALLATION INSTRUCTIONS (Continued)
ELECTRICAL CONNECTIONS
WARNING: Do not connect the appliance to the electrical supply until after the gas connection has been made.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. (120V units only).
The wiring compartment is located behind the control panel. For units operated on electrical supply other than 120 volts, remove the wiring compartment cover and make electrical connections per the wiring diagram located inside the control housing cover panel. The braising pan must be grounded in accordance with requirements of the National Electrical Code or applicable local code.
Replace wiring compartment cover.
Part No. 10094R2 9 2019-01-16