Crown Boiler BWC User Manual

D E S I G N E D T O L E A D
Concentric Vent Component Descriptions and Dimensional Data
WARNING: Improper installation, adjustment, alteration,
service or maintenance can cause property damage, injury, or loss of life. Use this venting only on Crown BWC Series boilers in accordance with the instructions provided with the boiler.
Manufacturer of Hydronic Heating Products
P.O. Box 14818 3633 I. Street
Philadelphia, PA 19134
Tel: (215) 535-8900 • Fax: (215) 535-9736 • www.crownboiler.com
TABLE OF CONTENTS
Cuttable Straight 1 Non-Cuttable Straight 2 Telescoping Straight 3 45° Elbow 4 90° Standard Elbow 5 90° Sweep Elbow 6 90° Support Elbow with Chimney Chase Bracket 7 60/100 Horizontal Vent Kit 8 Horizontal Terminal 9 Vertical Terminal 10 Flat Roof Flashing 11 25°- 45° Sloped Roof Flashing 12 Locking Band 13 Support Band 13 80/125 Snorkel Kit 14 Concentric Vent Adapter Kit for BWC150/225 Boilers 15 Stainless Steel Vent Collar Kit (BWC070, 090 & 120) 16
Important Notes for all Components:
1) “Vent Size” denotes nominal inner and outer pipe diameters in millimeters. For example “80/125” concentric components have an 80mm diameter inner pipe and a 125mm diameter outer pipe.
2) Dimensions shown are rounded as follows: a. Overall lengths (Dimensions ‘L’ ) are rounded to the nearest 1/2” b. All other dimensions are rounded to the nearest 1/8”
Cuttable Straight
P/N Vent Size ‘L’ 230506 60/100 19-1/2” 230517 80/125 19-1/2” 230515 80/125 39” 230560 100/150 19-1/2” 230562 100/150 39”
Note: Cut from male end only.
1
Non-Cuttable Straight
P/N Vent Size ‘L’ 230505 60/100 39” 230504 60/100 78” 230518 80/125 39” 230519 80/125 78” 230561 100/150 39” 230563 100/150 78”
2
Telescoping Straight
P/N Vent Size ‘L’ Range 230525 80/125 12-1/2” to 16-1/2” 230564 100/150 12-1/2” to 17-1/2”
3