Crouzet Timers Selection Guide

Selection guide
Chronos 2 DIN rail mounted, Timers
DIN rail modular casings
Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type
A / At / B / C / H / Ht
17.5 Screw terminals
Screw terminals
17.5
17.5 Screw terminals
17.5 Screw terminals
17.5 Screw terminals Ac / Ad / Bw / Cx / N / O / Tt Relay 1 x 5 A changeover 0.1 s => 20 h
Spring terminals
Screw terminals
A / At / B / C / H / Ht
Ad / Ah / N / O / P
A / At / B / C / H / Ht
A / At / B / C / H / Ht
A / At
B
C
H / Ht
L / Li
Pt / TL / Tt / W
A 24 C 240 V z
H / Ht
L / Li
A
Di / D / W / Pe
Relay 1 x 8 A changeover 0.1 s C 100 h
Relay 1 x 8 A changeover 0.1 s C 100 h
Solid state 0.7 A 0.1 s C 100 h
Relay 1 x 5A changeover 0.1 s C 20 h
24 V c / 24 C 240 V a
24 V c / 24 C 240 V a
24 V c / 24 C 240 V a
12 V z
12 V z
12 C 240 V z
24 C 240 V a
24 C 240 V a
240 V a 110 V a
24 V z
12 C 240 V c /
24 C 240 V a
12 C 240 V c /
24 C 240 V a
Timers
88 827 105 MUR1
88 827 115 MAR1 88 827 125 MBR1 88 827 135 MCR1 88 827 145 MHR1 88 827 150 MLR4 88 827 155 MLR1
88 827 100 MUR4
88 827 103 MUR3 88 827 503 MURc3
88 827 185 MXR1
88 827 004 MUS2
88 827 014 MAS5 88 827 044 MHS2 88 827 054 MLS2
88 829 117 EMAR7 88 829 112 EMAR2 88 829 119 EMAR9
88 829 198 EMER8
88 829 108 EMYR8
DIN rail industrial casings
Casing width (mm) Connections Functions Type of output Output(s) Timing Supply Part number Type
22.5 Screw terminals
22.5
22.5 Screw terminals
Screw terminals
Spring terminals
A / At / B / C / H / Ht
A / At
B
C
H / Ht
L / Li
Q
K 2 x 8 A changeover 0.1 s C 160 s
A / At / B / C / H / Ht
A / At 2 x 8 A changeover 24 V c / 24 C 240 V a
A / At / B / C / H / Ht
Ad / Ah / N / O / P
Pt / TL / Tt / W
Q 230 C 440 V a
A / At / B / C / H / Ht
Relay
Relay
Relay
1 x 8 A changeover 0.1 s C 100 h
1 x 8 A changeover
1 inst. or timed 8 A
1 x 8 A changeover
1 x 8 A changeover 12 C 240 V z
1 x 8 A changeover
1 inst. or timed 8 A
1 x 8 A changeover
1 x 8 A changeover
1 inst. or timed 8 A
* Available in 2014. The casing of the new range will be different from the ones presented here. Further information can be found on the data sheets available at www.crouzet.com
0.1 s C 100 h
0.1 s C 100 h
24 V c / 24 C 240 V a
24 V c / 24 C 240 V a
12 C 240 V z
24 V c / 24 C 240 V a
12 V z
88 865 105 TUR1
88 865 115 TAR1 88 865 125 TBR1 88 865 135 TCR1 88 865 145 THR1 88 865 155 TLR1 88 865 175 TQR1
88 866 175* RQR1*
88 865 265 TK2R1
88 865 300 TU2R4
88 866 300* RU2R4*
88 865 100 TUR4 88 865 215 TA2R1
88 866 215* RA2R1*
88 865 103 TUR3 88 865 503 TURc3
88 865 385 TX2R1
88 866 385* RX2R1*
88 865 185 TXR1 88 865 176 TQR6
88 866 176* RQR6*
88 865 303 TU2R3
88 866 303* RU2R3*
88 865 305 TU2R1
88 866 305* RU2R1*
14 15
I www.crouzet.com
l Panorama Crouzet Control
Selection guide
Plug-in industrial casings
Casing width (mm) Connections Functions (detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type
A / At / B / C / H / Ht
35
35
21
Plug-in
8-pin base
A / At / B / C / H / Ht
A / At / B / C / H / Ht
Plug-in
11-pin base
A / At / B / C / H / Ht
Plug-in
8-pin base
Plug-in
14-pin base
A 2 x 8 A changeover
C
L / Li
A
C
L / Li
A Relay
Relay
Relay
1 x 8 A changeover
1 x 8 A changeover
1 x 8 A changeover
1 inst. or timed 8 A
2 x 8 A changeover
1 x 8 A changeover
1 inst. or timed 8 A
2 x 5 A changeover
4 x 3 A changeover
0.1s C 100 h
0.1s C 100 h
0.1s C 100 h
24 V c / 24 C 240 V a
12 V z
12 C 240 V z
24 V c / 24 C 240 V a
12 V z
12 C 240 V z
12 V c 24 V c
24 V a 110 V a 230 V a
12 V c
24 V c
24 V a 110 V a 230 V a
88 867 105 OUR1
88 867 215 OA2R1 88 867 135 OCR1 88 867 155 OLR1
88 867 100 OUR4
88 867 103 OUR3
88 867 305 PU2R1
88 867 415 PA2R1 88 867 435 PC2R1 88 867 455 PL2R1 88 867 300 PU2R4 88 867 303 PU2R3 88 895 201 RTMA2 88 895 202 RTMA2 88 895 203 RTMA2 88 895 206 RTMA2 88 895 207 RTMA2 88 896 201 RTMA4 88 896 202 RTMA4 88 896 203 RTMA4 88 896 206 RTMA4 88 896 207 RTMA4
Timers
"Panel mounted", Timers
Analogue - TMR48 series
Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type
Plug-in
11-pin base
48 x 48
Plug-in
8-pin base
Digital
Dimensions (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Supply Part number Type
48 x 48
48 x 48
48 x 48
48 x 48
Accessories available: base socket 8-pin for DIN Rail mount 25 622 130, base socket 11-pin for DIN Rail mount 25 622 080.
Plug-in
8-pin base
Plug-in
11-pin base
Plug-in
11-pin base
Plug-in
8-pin base
Plug-in
11-pin base
A1, A1C, A2, A2C, AM, AMt, B, BM, C, CM, D,
Di, DiM, Dpause, H, HM, T,TM, W, WM
L / Li - G / Gi
A, B, C, W, G, Ac, Bw
A
A1, A2, H1, H2, Q1, Q2, D-Di
A
A, B, C, D, Di, H 1 x 8 A timed changeover
A, B, C, D, Di, H
A1, A2, AM, AMt
A, B, C, D, Di, H Relay 1 x 8 A timed changeover
2 timed changeover
Relay
1 timed and 1 instantaneous
Relay
1 x 8 A timed changeover
Relay
1 instantaneous (2 x 8 A)
Relay
1 instantaneous (2 x 5 A)
The timer accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com
2 x 5 A
2 timed changeover or
(2 x 5 A)
2 timed changeover
2 x 5 A
2 timed changeover or
1 timed and
2 timed changeover or
1 timed and
12 C 240 V c
24 C 240 V a
24 V z 110 V a
220 C 240 V a
12 V c / 24 C 48 V z
24 V z / 110 C 240 V a
12 V c / 24 C 48 V z
24 V z / 110 C 240 V a
12 V c / 42 C 48 V z
24 V z / 110 V a
24 V c / 220 C 240 V a
12-24 V z / 100C240 V a
24 V z / 48 V z
24 V z / 110 V a
24 V z / 220 C 240 V a
24 V z / 48 V z
24 V z / 110 V a
24 V z / 220 C 240 V a
88 886 516 TMR 48 L 88 886 016 TMR 48 U 88 886 106 TMR 48 A
88 886 116 TMR 48 X
88 857 409 Timer 812 88 857 406 Timer 812 88 857 400 Timer 812 88 857 003 Timer 814 88 857 005 Timer 814 88 857 103 Timer 814 88 857 105 Timer 814 88 857 302 Timer 815 88 857 307 Timer 815 88 857 301 Timer 815
88 857 311 Timer 815E
88 857 604 Timer 816 88 857 607 Timer 816 88 857 601 Timer 816 88 857 704 Timer 816 88 857 707 Timer 816 88 857 701 Timer 816
16 17
I www.crouzet.com
l Panorama Crouzet Control
Selection guide
MBA series
Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type
22 (diameter) Screw terminals A Solid state 400 mA
22 (diameter) Screw terminals A Solid state 200 mA
Electromechanical - Top 2000 range
Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type
Screw terminals
48 x 48
Plug-in 8-pin base
Screw terminals
48 x 48
Plug-in 8-pin base
2-3-4 Relay
2-3-4 Relay
1 timed changeover and
1 timed instantaneous
(2 x 5 A)
1 timed changeover and
1 timed instantaneous
(2 x 5 A)
0.1 s C 1 s
0.5 s C 10 s 3 s C 60 s
0.5 min C 10 min 3 min C 60 min
0.1 s C 1 s
0.5 s C 10 s 3 s C 60 s
0.5 min C 10 min 3 min C 60 min
6 s C 12 mn
6 mn C 12 h
100 C 240 V z
24 V c
24 V a
42 C 48 V a 110 C 127 V a 220 C 240 V a
24 V a
42 C 48 V a 110 C 127 V a 220 C 240 V a
24 V a
24 V a 42 C 48 V a 42 C 48 V a
110 C 127 V a 110 C 127 V a 220 C 240 V a 220 C 240 V a
88 901 308 MBA2F 88 901 328 MBA2F 88 901 348 MBA2F 88 901 378 MBA2F 88 901 398 MBA2F 88 901 302 MBA3F 88 901 322 MBA3F 88 901 342 MBA3F 88 901 372 MBA3F 88 901 392 MBA3F
88 226 013 Top 2 000 88 226 019 Top 2 000 88 226 012 Top 2 000 88 226 011 Top 2 000 88 226 501 Top 2 000 88 226 502 Top 2 000 88 226 503 Top 2 000 88 226 504 Top 2 000 88 226 016 Top 2 000 88 226 505 Top 2 000 88 226 017 Top 2 000 88 226 506 Top 2 000 88 226 015 Top 2 000 88 226 507 Top 2 000 88 226 014 Top 2 000 88 226 508 Top 2 000
Timers
Manual reset
Casing width (mm) Connections Functions (Detail on pages 20 to 23) Type of output Output(s) Timing Supply Part number Type
55
55
55
Faston connectors
6.35 mm
Faston connectors
6.35 mm
Faston connectors
6.35 mm
A Relay
A Relay
A Relay
5 min (Max.display time : 4 min 40 s)
15 min (Max.display time : 14 min) 30 min (Max.display time : 28 min)
1 x 16 A timed
changeover
2 x 16 A timed
changeover
3 x 16 A timed
changeover
The timer accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet.com
60 min (Max.display time : 56 min)
120 min (Max.display time : 1 h 53 min)
5 h (Max.display time : 4 h 43 min) 15 h (Max.display time : 14 h 10 min) 30 h (Max.display time : 28 h 20 min)
5 min (Max.display time : 4 min 40 s)
15 min (Max.display time : 14 min)
30 min (Max.display time : 28 min) 60 min (Max.display time : 56 min)
120 min (Max.display time : 1 h 53 min)
5 h (Max.display time : 4 h 43 min) 15 h (Max.display time : 14 h 10 min) 30 h (Max.display time : 28 h 20 min)
5 min (Max.display time : 4 min 40 s)
15 min (Max.display time : 14 min) 30 min (Max.display time : 28 min) 60 min (Max.display time : 56 min)
120 min (Max.display time : 1 h 53 min)
5 h (Max.display time : 4 h 43 min) 15 h (Max.display time : 14 h 10 min) 30 h (Max.display time : 28 h 20 min)
127 / 230 V a
50 Hz
127 / 230 V a
50 Hz
127 / 230 V a
50 Hz
88 256 401 88 256 4 88 256 402 88 256 4 88 256 403 88 256 4 88 256 404 88 256 4 88 256 405 88 256 4 88 256 406 88 256 4 88 256 407 88 256 4 88 256 408 88 256 4 88 256 506 88 256 5 88 256 507 88 256 5 88 256 508 88 256 5 88 256 509 88 256 5 88 256 510 88 256 5 88 256 511 88 256 5 88 256 512 88 256 5 88 256 513 88 256 5 88 256 906 88 256 9 88 256 907 88 256 9 88 256 908 88 256 9 88 256 909 88 256 9 88 256 910 88 256 9 88 256 911 88 256 9 88 256 912 88 256 9 88 256 913 88 256 9
18 19
I www.crouzet.com
l Panorama Crouzet Control
U : Supply R : Output relay
or load
T : Timing
: Innity
C (Y1) : Command
Function diagrams
Generic functions
• A function: Delay on energisation
1 relay
Single shot timing which starts
on energisation.
• Ac function: Timing after closing and opening
of control contact
1 relay
After energisation, closing of the control contact results in starting of the time delay T. Output relay "R" (or the load) changes state at the end of this time delay. After opening of contact C (Y1), relay "R" drops out after a second time delay T.
• Ad function: Delay on energisation
1 relay
(cannot be reset)
After energisation, a control pulse
At the end of timing, the output
• Ah function: Single shot flip-flop
2 timers or 2 relays including 1 instantaneous
• At function: Timing on energisation
with memory
1 relay
Adds up the opening time of a contact.
Output relay "R" (or the load) changes state at the end of timing.
• A1 function: Delay on energisation
or latching contact starts timing.
is excited. The output will be reset when a new control pulse or latching contact occurs.
(cannot be reset)
After energisation, a control pulse or latching contact starts timing. At the end of timing, the output is excited. The time delay is then reset. At the end of this new time delay, the output reverts to its initial value.
1 timer 1 instantaneous relay
• A2 function: Delay on energisation
2 timers.
• AM function: Delay on energisation
Latching during the time delay.
• AMt function: Delay on energisation
Latching during and after
the time delay.
• B function: Timing on impulse (one shot) -
Shaping (cannot be reset)
1 relay
After energisation, an impulse (≥ 50 ms) or a latching contact causes a change in state of the output relay "R" (or the load) which drops out at the end of timing.
• Bw function: Pulse output (adjustable)
1 relay
On closing and opening of the control contact C (Y1), the output relay "R" (or the load) changes state for as long as the time delay lasts.
2 timers or 2 relays including 1 instantaneous
• C function: Timing after impulse
True delay off
(without auxiliary power supply)
1 relay
After energisation, closing of the control contact C (Y1) results in the change of state of output relay "R" (or the load). Timing will only start when this
contact opens.
• D or Di functions: Symmetrical flashing
Repetitive cycle which alternately sets the output relay "R" (or the load) to operating and rest position for equal periods of time.
1 relay
D function: The cycle starts with relay "R" in rest position.
1 relay
The cycle starts with relay "R" in operating position.
Di function:
U : Supply R : Output relay
or load
T : Timing
: Innity
C (Y1) : Command
• H function: Timing on energisation -
Pulse output (adjustable)
1 relay
On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the single shot cycle.
• Ht function: Delay on energisation with memory
1 relay
Adds up the total opening time
On energisation, the output relay "R" (or the load) changes state, and stays there for the whole duration of the time delay and drops out at the end of the
single shot cycle.
of a contact.
• K function: Delay on de-energisation
True delay off
(without auxiliary power supply)
1 relay
On energisation, the output relay "R" (or the load) changes state. On de-energisation timing starts and the relay "R" will only drop out at the end of this time delay.
• L function: Asymmetrical flashing
1 relay
Repetitive cycle with two times which can be set independently. Each time delay alternates with a different state of the output relay
2 timers or 2 relays including
"R" (or the load).
1 instantaneous
Note: The cycle starts with the relay
"R"
in the rest position.
• Li function: Asymmetrical flashing
1 relay
Repetitive cycle with two times which can be set independently.
• N function: "Safe-guard"
On the rst control pulse,
the output is excited. If the interval between two impulses is longer than the timing value, this occurs normally and the output relay "R" (or the load) will change state at the end of timing. Otherwise, relay "R" stays in its original state until the condition is fullled.
• O function: "Delayed safe-guard"
On energisation, a rst timer runs and the output relay "R" (or the load) changes state. On the appearance of a control pulse, relay "R" returns to its initial
the time interval between 2 impulses is less than the timing value. Otherwise, relay "R" will change state at the end of timing.
position and stays there as long as
• P and Pe functions: Impulse counter (delay on)
P function:
Timing starts on energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 500 ms.
Pe function:
On energisation. At the end of timing, the output relay "R" (or the load) changes state for approximately 1 s.
• Pt function: Impulse counter (delay on)
Adds up the total opening time of a contact. At the end of timing, the output is excited for approximately 500 ms.
• Q function: "Star-delta" starting
On energisation, the "star" contact closes instantaneously and timing starts. At the end of timing the Ti "star" contact opens. After a pause of 40 to 100 ms the "delta" contact
closes.
• TL function: Impulse relay
After energisation, a control pulse
or latching contact closes the
relay. A second control pulse
opens the relay.
• Tt function: Timed impulse relay
After energisation, a control pulse
or latching contact closes the relay
and starts timing. The relay opens at the end of timing or on a second control pulse.
• W function: Timing after pulse on control contact
After energisation, opening of the
control contact results in a change in the state of output "R" (or the load) and timing starting.
Timers
20 21
I www.crouzet.com
l Panorama Crouzet Control
Function diagrams
U : Supply R : Output relay
or load
T : Timing
: Innity
C (Y1) : Command Start : Start timing Reset : Reset to zero
815E dedicated functions
• A2 function:
• AM function:
Latching during the time delay
• B function:
• C function:
• D function:
Delay on energisation
Delay on energisation
Timing on impulse (one shot)
Timing after impulse
Flip-flop
• A2c function:
• AMt function:
Latching during the time delay
• B function with latching:
(one shot)
• C function with latching:
• Di function:
Delay on energisation
Delay on energisation
Timing on impulse
Timing after impulse
Flip-flop
U : Supply R : Output relay
or load
T : Timing
: Innity
C (Y1) : Command
TMR48 dedicated functions
• TMR48 A A function: Delay on
energisation
• TMR48 U A function: On-delay
• A1 function: Delay on energisation
• A2 function: Delay on energisation
• D-Di function: Symmetrical flashing
• Ac function: Timing after closing and
opening of control contact
• B function: Timing on impulse (one shot)
• Bw function: Pulse output (adjustable)
• C function: Off-delay
Timers
• Di function with latching:
• H function:
• T function:
• W function:
Timing on energisation
Timing on energisation
Off-delay
Flip-flop
• D pause function:
• H function with latching:
• T function with latching:
• W function with latching:
Flip-flop
Timing on energisation
Timing on energisation
Off-delay timer
• H1 function: Timing on energisation
• G function: Cyclical function
• H2 function: Timing on energisation
• L/LiG/Gi function: Cyclical flashing timers
• Q1 function: Star-delta "starting"
• W function: Off-delay
• Q2 function: "Star-delta 2" starting
22 23
I www.crouzet.com
l Panorama Crouzet Control