Crouzet MDE1R0524U, MDE1R05MVA, MDA2R10MV2, MDF1R10MV2, GDF1R10MV2 Data Sheet

...
Large LED or LCD Screen (13.2 mm) Multi-function and single-function Basic & Advance configuration modes Multi-range (0.05 s – 9999 h) Multi-voltage (24-240 V AC/DC) 1 or 2 relay outputs (Changeover) Memory option in event of a break in supply Lock function Up or down timing DIN Sized (48x48 mm) Housing Compact body (63 mm long) Water & Dust-proof (IP66) 8-Pins & 11-Pins connections
Standard Version (MDE1)
Performance Version
(MDA2, MDF1, GDF1, GDS2)
Type
Part Number
Function
Connections
Output
Supply Voltage
Screen
MDE1
MDE1R0524U
A, B, C, H, D, Di
8-Pins
1 x 5A
24 V AC/DC
LCD
MDE1
MDE1R05MVA
A, B, C, H, D, Di
8-Pins
1 x 5A
100-240 V AC/DC
LCD
MDA2
MDA2R10MV2
A
8-Pins
2 x 10A
24-240 V AC/DC
LED
MDF1
MDF1R10MV2
A, Ac, Ad, B, C, H, L, Li, D, Di
8-Pins
1 x 10A
24-240 V AC/DC
LED
GDF1
GDF1R10MV2
A, Ac, Ad, B, C, H, L, Li, D, Di
11-Pins
1 x 10A
24-240 V AC/DC
LED
GDS2
GDS2R10MV2
A, Ab, Ac, Ad, AMt, At, B, C, H, Ht, L, Li, T, W, D, Di
11-Pins
2 x 10A
24-240 V AC/DC
LED
Syr-line TMR48D
Digital Timer
Front Panel 48x48 (1/16 DIN)
Function
A: ON-Delay E: Multifunction E F: Multifunction F S: Multifunction S
Type
MD: Digital 8-Pins GD: Digital 11-Pins
Output Quantity
1: 1 Output 2: 2 Outputs
Output Type
R: Relay
Output Power
10: 10 A 05: 5 A
Power Supply
MV2: 24-240 V AC/DC MVA: 100-240 V AC/DC 24U: 24 V AC/DC
GD
S 2 R
10
MV2
Product Selection
Description:
The new Syr-line Digital Timers has higher precision and many programming features with the biggest screen ever seen in the timer relays’ market and the most intuitive programming for ease to use and fast configuration
Input Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
Rated supply voltage Un
24 V AC/DC
100-240 V
AC/DC
24-240 V
AC/DC
24-240 V
AC/DC
24-240 V
AC/DC
24-240 V
AC/DC
Voltage supply tolerance
-15 %, +10 %
AC supply voltage frequency
50 / 60 Hz +/- 5%
Galvanic isolation of supply / inputs
No
Max power consumption @ Un
2.5 VA (VAC) 1 W (VDC)
Immunity to power micro cuts
10 ms
Timing Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
Specified time ranges (10)
IEC 1812-1: 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59
s, 0.1 min to 999.9 min, 1 min to 9999min, 1 min to 99h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h
Minimum control pulse duration
IEC 1812-1: 1 ms or 20 ms selectable
Recovery time (after by de-energization)
IEC 1812-1: 120 ms Max
Repeatability
IEC 1812-1: ≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
Setting Accuracy
IEC 1812-1: ≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
Temperature drift
≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
Voltage drift
≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
Output Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
Contact arrangement
1 CO (SPDT)
1 CO (SPDT)
2 CO (SPDT)
Maximum switching voltage
250 VAC / 30 VDC
250 VAC / 10 A resistive /
125 VDC / 0.3 A resistive
250 VAC / 10 A resistive /
125 VDC / 0.3 A resistive
Switching current rate (resistive)
NO: 5A 250 VAC / 5 A 30 VDC
- NC: 3A 250 VAC / 3 A 30 VDC
NO / NC: 10 A 250 VAC / 10 A
30 VDC
NO/NC: 2x10 A @ 40 °C 250 V
AC / 2x10 A @ 40 °C 30 VDC
NO / NC: 2x8 A @ 60 °C 250 V
AC / 2x8A @ 60 °C 30 VDC
Maximum switching power (resistive)
NO: 1250 VA / 150 W – NC:
750 VA / 90 W
2500 VA / 300 W
2 x 2500 VA / 2 x 300 W
Electrical life at nominal switching current rate (resistive)
1x105 cycles NO
7x104 cycles NC
1x105 cycles (10 A 250 VAC
resistive)
1x105 cycles (10 A 250 VAC
resistive)
Minimum switching contact
10 mA / 12 VDC
Maximum rate (at max switching power)
360 cycles /hour
Mechanical life
10 x 106 cycles
Dielectric strength between open contacts
1 kV / 1 min / 1 mA / 50 Hz
Insulation Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
Rated Insulation voltage
IEC 60664-1: 300 V
Insulation coordination
IEC 60664-1: Overvoltage category III; pollution degree 2
Rated impulse voltage
IEC 60664-1: 4 kV (1.2/50 μs)
Clearance / Creepage distances
IEC 60664-1: 3 mm / 3.2 mm
Dielectric strength
EN-61812-1: 2.5 kV / 1 min / 1 mA / 50 Hz
Insulation Resistance
NFC 93 050: > 500 MΩ / 250 VDC / 1min
General Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
Display
4 digits per
value
7 segments
LCD
4 digits per
value
7 segments
LCD
4 digits per
value
7 segments
LCD with backlight
4 digits per
value
7 segments
LCD with backlight
4 digits per
value
7 segments
LCD with backlight
4 digits per
value
7 segments
LCD with backlight
Memory backup
EEPROM (rewrite 1,000,000 times min, 40 years data hold min)
Casing
48x48 mm (1/16 DIN)
Mounting position
All positions
Mounting
Mounting Front panel, by clip
Mounting base-mounted on socket
Housing material
UL94: enclosure plastic type V0
Degree of protection (Front Face)
IEC 60529: IP66 with front panel seal
Degree of protection (Housing)
IEC 60529: IP20
Operating temperature
IEC 60068-2: -10 °C to +60 °C
Storage temperature
IEC 60068-2: -30 °C to +70 °C
Humidity
IEC 60068-2-30: 93 % without condensation
Vibration resistance
IEC 60068-2-6: ±0.15 mm 10 Hz - 60 Hz
2 g 60 Hz - 150 Hz
Shock resistance
IEC60068-2-27: 15 gn – 11 ms, 3 x 6 axis (Output non-energized)
5gn – 11 ms, 3 x 6 axis (Output energized)
Drop to concrete floor
IEC 60068-2-32: Height: 0.75 m
Weight
Approx. 105 g (150 g with packing)
Standards Specifications
Description
MDE1…24U
MDE1…MVA
GDF1
MDF1
MDA2
GDS2
EU Directives
2014/30/EU: EMC,
2014/35/EU: Low voltage
Approvals / Marking
CE, cULus Listed Industrial Control Equipment
Security standard
IEC 60664-1: Insulation coordination for equipment within low-voltage systems
Conformity with environmental directives
2015/863/UE: RoHS
1907/2006: Reach
2012/19/UE: WEEE
Product standard
IEC 61812-1: Specified time relays for industrial use
UL 508 (60947-4-1): Industrial Control Equipment (NRNT- Industrial Control Switches)
Immunity to electrostatic discharges
Level III Air +/-8 KV / Contact +/-6 KV
Immunity to radiated, radio-frequency, electromagnetic field
IEC61000-4-3: Level III, 10 V/m (80 MHz to 1 GHz) 80% AM (1 kHz), 3 V/m (1.4 to 2 GHz)
80% AM (1 KHz), 1 V/m (2 to 2.7 GHz) 80% AM (1 KHz)
Immunity to rapid transient bursts
IEC 61000-4-4: Level IV, direct +/-4 kV (power supply) / capacitive coupling clamp +/-2 KV,
(command input and outputs)
Immunity to shock waves on power supply
IEC 61000-4-5: Level III, line-to-earth +/-2 kV / line-to-line +/-1 kV
Immunity to radiofrequency in common mode
IEC 61000-4-6: Level III, 10 Vrms (0,15 to 80 MHz) 80% AM (1 kHz)
Immunity to voltage dips and breaks
IEC 61000-4-11:
Industrial Class II, 0 % residual voltage during 1 cycle AC power ports, 70 % residual voltage
during 25/30 cycles AC power ports, 0 % residual voltage, 250/300 cycles AC power ports.
Residential: 0 % residual voltage during 10 cycle AC power ports, 40 % residual voltage
during 10 cycles AC power ports, 70 % residual voltage during 10 cycles AC power ports, 0 %
residual voltage, 250/300 cycles AC power ports
AC/DC main port emissions
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1
Radiated emissions
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1
Dimensions in(mm)
Side View
Front View
Mounting
Panel Cut-Out
Loading...