› Large LED or LCD Screen (13.2 mm)
› Multi-function and single-function
› Basic & Advance configuration modes
› Multi-range (0.05 s – 9999 h)
› Multi-voltage (24-240 V AC/DC)
› 1 or 2 relay outputs (Changeover)
› Memory option in event of a break in supply
› Lock function
› Up or down timing
› DIN Sized (48x48 mm) Housing
› Compact body (63 mm long)
› Water & Dust-proof (IP66)
› 8-Pins & 11-Pins connections
Performance Version
(MDA2, MDF1, GDF1, GDS2)
A, Ac, Ad, B, C, H, L, Li, D, Di
A, Ac, Ad, B, C, H, L, Li, D, Di
A, Ab, Ac, Ad, AMt, At, B, C, H, Ht, L, Li, T, W, D, Di
Syr-line TMR48D
Digital Timer
Front Panel 48x48 (1/16 DIN)
Function
A: ON-Delay
E: Multifunction E
F: Multifunction F
S: Multifunction S
Type
MD: Digital 8-Pins
GD: Digital 11-Pins
Output Quantity
1: 1 Output
2: 2 Outputs
Output Power
10: 10 A
05: 5 A
Power Supply
MV2: 24-240 V AC/DC
MVA: 100-240 V AC/DC
24U: 24 V AC/DC
Product Selection
Description:
The new Syr-line Digital Timers has higher precision and many programming features with the biggest screen ever seen in the timer relays’
market and the most intuitive programming for ease to use and fast configuration

AC supply voltage frequency
Galvanic isolation of supply / inputs
Max power consumption @ Un
Immunity to power micro cuts
Specified time ranges (10)
IEC 1812-1: 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 1 s to 99 min 59
s, 0.1 min to 999.9 min, 1 min to 9999min, 1 min to 99h 59 min, 0.1 h to 999.9 h, 1 h to 9999 h
Minimum control pulse duration
IEC 1812-1: 1 ms or 20 ms selectable
Recovery time (after by de-energization)
IEC 1812-1: ≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
IEC 1812-1: ≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
≤ ± 0.03 % ± 20 ms (VDC) / 50 ms (VAC)
Maximum switching voltage
250 VAC / 10 A resistive /
125 VDC / 0.3 A resistive
250 VAC / 10 A resistive /
125 VDC / 0.3 A resistive
Switching current rate (resistive)
NO: 5A 250 VAC / 5 A 30 VDC
- NC: 3A 250 VAC / 3 A 30
VDC
NO / NC: 10 A 250 VAC / 10 A
30 VDC
NO/NC: 2x10 A @ 40 °C 250 V
AC / 2x10 A @ 40 °C 30 VDC
NO / NC: 2x8 A @ 60 °C 250 V
AC / 2x8A @ 60 °C 30 VDC
Maximum switching power (resistive)
NO: 1250 VA / 150 W – NC:
750 VA / 90 W
Electrical life at nominal switching current
rate (resistive)
1x105 cycles NO
7x104 cycles NC
1x105 cycles (10 A 250 VAC
resistive)
1x105 cycles (10 A 250 VAC
resistive)
Minimum switching contact
Maximum rate (at max switching power)
Dielectric strength between open contacts
1 kV / 1 min / 1 mA / 50 Hz

Insulation Specifications
IEC 60664-1: Overvoltage category III; pollution degree 2
IEC 60664-1: 4 kV (1.2/50 μs)
Clearance / Creepage distances
IEC 60664-1: 3 mm / 3.2 mm
EN-61812-1: 2.5 kV / 1 min / 1 mA / 50 Hz
NFC 93 050: > 500 MΩ / 250 VDC / 1min
4 digits per
value
7 segments
LCD
4 digits per
value
7 segments
LCD
4 digits per
value
7 segments
LCD with
backlight
4 digits per
value
7 segments
LCD with
backlight
4 digits per
value
7 segments
LCD with
backlight
4 digits per
value
7 segments
LCD with
backlight
EEPROM (rewrite 1,000,000 times min, 40 years data hold min)
Mounting Front panel, by clip
Mounting base-mounted on socket
UL94: enclosure plastic type V0
Degree of protection (Front Face)
IEC 60529: IP66 with front panel seal
Degree of protection (Housing)
IEC 60068-2: -10 °C to +60 °C
IEC 60068-2: -30 °C to +70 °C
IEC 60068-2-30: 93 % without condensation
IEC 60068-2-6: ±0.15 mm 10 Hz - 60 Hz
2 g 60 Hz - 150 Hz
IEC60068-2-27: 15 gn – 11 ms, 3 x 6 axis (Output non-energized)
5gn – 11 ms, 3 x 6 axis (Output energized)
IEC 60068-2-32: Height: 0.75 m
Approx. 105 g (150 g with packing)

2014/30/EU: EMC,
2014/35/EU: Low voltage
CE, cULus Listed Industrial Control Equipment
IEC 60664-1: Insulation coordination for equipment within low-voltage systems
Conformity with environmental directives
2015/863/UE: RoHS
1907/2006: Reach
2012/19/UE: WEEE
IEC 61812-1: Specified time relays for industrial use
UL 508 (60947-4-1): Industrial Control Equipment (NRNT- Industrial Control Switches)
Immunity to electrostatic discharges
Level III Air +/-8 KV / Contact +/-6 KV
Immunity to radiated, radio-frequency,
electromagnetic field
IEC61000-4-3: Level III, 10 V/m (80 MHz to 1 GHz) 80% AM (1 kHz), 3 V/m (1.4 to 2 GHz)
80% AM (1 KHz), 1 V/m (2 to 2.7 GHz) 80% AM (1 KHz)
Immunity to rapid transient bursts
IEC 61000-4-4: Level IV, direct +/-4 kV (power supply) / capacitive coupling clamp +/-2 KV,
(command input and outputs)
Immunity to shock waves on power supply
IEC 61000-4-5: Level III, line-to-earth +/-2 kV / line-to-line +/-1 kV
Immunity to radiofrequency in common
mode
IEC 61000-4-6: Level III, 10 Vrms (0,15 to 80 MHz) 80% AM (1 kHz)
Immunity to voltage dips and breaks
IEC 61000-4-11:
Industrial Class II, 0 % residual voltage during 1 cycle AC power ports, 70 % residual voltage
during 25/30 cycles AC power ports, 0 % residual voltage, 250/300 cycles AC power ports.
Residential: 0 % residual voltage during 10 cycle AC power ports, 40 % residual voltage
during 10 cycles AC power ports, 70 % residual voltage during 10 cycles AC power ports, 0 %
residual voltage, 250/300 cycles AC power ports
AC/DC main port emissions
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1
EN55022 / CISPR22 Class B
EN 55011 / CISPR11 Class B, Group 1

FUNCTION A: On-Delay (Delay on make)
FUNCTION A + Memory Option
FUNCTION Ab: Delayed Interval
FUNCTION Ab + Memory Option
FUNCTION Ac: On/Off Delay (Delay on
make/break)

FUNCTION Ac + Memory Option
FUNCTION Ad: Delay on Start
FUNCTION Ad + Memory Option
FUNCTION At: Summation Time Relay
FUNCTION At + Memory Option
t2A+t2B=T2 t2 t2A t2B t t t

FUNCTION AMt: On-Delay (Delay on
make, Total memory: one delay)
FUNCTION B + Memory Option
FUNCTION C: Off-Delay (Delay on break)
FUNCTION C + Memory Option

FUNCTION H + Memory Option
FUNCTION Ht: interval summation time relay
FUNCTION Ht + Memory Option
FUNCTION L: Recycler (OFF Start)

FUNCTION L + Memory Option
FUNCTION Li: Recycler (ON Start)
FUNCTION Li + Memory Option
FUNCTION T: On-Delay (Delay on make):
sum of times
FUNCTION T + Memory Option
T = t1 + t2 + t3 t1 t2 t3 t1 t1 t2 t3
T = t1 + t2 + t3
t2A t2B
t2 = t2A + t2B

FUNCTION W: Timing after pulse of control
contact
FUNCTION W + Memory Option
FUNCTION D: Symmetrical flashing (OFF
start)
FUNCTION D + Memory Option
FUNCTION Di: Symmetrical flashing (ON
start)

FUNCTION Di + Memory Option
Check Configured Time and Function

Pass
If "Lock" function is on, pass needs to be entered
Basic Prog
Enter to Basic Programming Mode
Advanced Prog
Enter to Advanced Programming Mode
Function
Select the timing function
A Ab Ac Ad AMt At B C
H Ht L Li D Di T W
Time Range
Select the timing range
-.---s --.--s ---.-s ----s --m--s
---.-m ----m --h--m ---.-h ----h
Count
Select the timing count up or down
Memory
Activate memory option (save timing after power off)
Output 2
Select if Out 2 works timed or instantaneous (MDA2, GDS2)
Input Time
Select input time wave
Input Type
Select input to work with a NPN or PNP signal
Time Limit
Select upper time limit
Programming Mode

Brightness
Select screen brightness
Sleep After
Select the time needed to turn off the screen
Lock
Select security level 1 (lock configuration) or 2 (lock all)
Pass
Set password for lock option
Done
Indication that the lock is on
Default Settings
Reset settings to default values
Sure
Confirm if reset settings to default values
Done
Indication that settings have been reset
Out 1
Turn on/off Relay Output 1
Out 2
Turn on/off Relay Output 2 (MDA2, GDS2)
Display
Turn on/off all display segments
Memory
Test the memory of the timer
Good
Indication that the memory is working properly
Error
Indication that the memory is not working properly
All specifications in this document are subject to change without written notice. Actual product may differ from pictures provided in this document.