Crouzet GA1 SERIES, GA8 SERIES Catalog Page

SOLID STATE RELAYS
0.04 (1.0) DIA. TYP.
0.375 (9,5)
0.25 (6,4)
1.4 (35,6)
0.8 (20,3)
1.2 (30,5)
0.15 (3,8)
1.1 (27,9)
0.15 (3,8)
1.5 (38,2)
0.3 (7,6)
(INPUT)
(OUTPUT)
43+
21
EQUIVALENT CIRCUIT
TRIGGER
CIRCUIT
4
3
1
2
+
GA1 & GA8 SERIES DC INPUT
SNUBBER
1.0 (25,4)
43 2 1
1.7 (43,2)
0.3 (7,6)
0.7 (17,8)
1.2 (30,5)
1.4 (35,5)
0.042 (1,1) DIA
0.035 (,89)
0.245 (6,2)
0.4 (10,2)
0.1 (2,5)
GA1, GA8, SERIES
High Current Thyristor for 100A Surge CapabilityUL Recognized/Horse Power Rated (GA8)
4KV Optical Isolation
Zero Voltage Turn-OnIndustry Standard Packaging, SIP or Flat PackForm A OutputCE Compliant
GA1
GA8
DIMENSIONS: inches (mm) TOLERANCE: ±0.020 (±0,50)
DIMENSIONS: TOLERANCE: ±0.020 (±0,50)
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-18
inches (mm)
Products and specifications subject to change without notice.
Consult factory for application assistance.
SOLID STATE RELAYS
GA1, GA8, SERIES
INPUT SPECIFICATIONS: (1)
Parameter GA86B02 GA86D05R Units
Minimum Turn-On Voltage 3.0 3.0 VDC Maximum Input Voltage 28 28 VDC Drop Out Voltage 1.0 1.0 VDC Maximum Input Current (2) 16 16 mADC Nominal Input Resistance (3) Current Regulated
GA16B02 GA86D05
OUTPUT SPECIFICATIONS:
Model Number GA16B02 (10) GA86D05
Parameter
Nominal Line Voltage 240 240 Vrms Minimum Line Voltage 24 24 Vrms Maximum Line Voltage 280 280 Vrms Maximum Peak Off-State Voltage(4) ±600 ±600 Vpeak Static (Off-State) dv/dt 200 200 V/
Parameter GA86B02 GA86D05R Units
Maximum On-State Current (5) 4.0 5.0 Arms Minimum On-State Current .05 .05 Arms Maximum 1-Cycle Surge (6) 100 100 Apeak On-State Voltage Drop (7) 1.6 1.6 Vpeak Maximum Off-State Leakage (8)
240V Models .1 .1 mArms
HP Rating (11) 1/4 1/4 H.P.
GA86B02 GA86D05R Units
S
GA16B02 GA86D05
GENERAL SPECIFICATION: (1)
Parameter All Devices Units
Operating Temperature Range -30 to +80 °C Storage Temperature Range -40 to +100 °C Response Time (12) .5 Cycle Input to Output Isolation Voltage (9) 4000 Vrms Capacitance Input to Output (Typ) 8 pF Line Frequency Range 47 to 63 Hz
1
Note: GA1-2B and GA1-4B have been replaced by GA1-6B
GA8-2B and GA8-4B have been replaced by GA8-6B
Notes:
(1) Specifications apply to Ta -30 TO +80 unless otherwise noted. (2) At maximum input voltage. (3) Does not include IRED impedance (drop). (4) One minute maximum duration when applied as a DC Voltage. (5) At Ta of 20°C, derate by 25 mA/°C to 40°C, 50 mA/°C from
40°C to 80°C. UL rating is 3.5 Arms, CSA rating is 3.0 Arms. (6) At Ta of 25°C, non-repetitive. (7) At Ta of 25°C and maximum on-state current. (8) At Ta of 25°C and maximum line voltage. (9) At Ta of 25°C, for one second.
(10) Random turn-on versions available. Specify by adding suffix “R” to
appropriate part number. Contact factory for additional details.
(11) For GA8 only, 1/4 H.P. at 240 VAC, 1/8 HP at 120 VAC (12) AT 60 Hz 100 µS for Random Turn-on
(suffix “R”) models
Products and specifications subject to change without notice.
5 AMP. GA8 DERATING CURVE
10
9
8
7
6
5
4
AMP. A rms
3
2
1
0
–30 –20 –10 0 10 20 30 40 50 60 70 80
TEMPERATURE DEGREE C
Consult factory for application assistance.
204 Airline Drive, Suite 300, Coppell, Texas 75019 / Tel: (800) 677-5311 / FAX: (800) 677-3865 / www.crouzet-usa.com
1-19
Loading...