o
Safety relay
➜ Emergency stop
KNA3-XS / KNA3-RS / KZP3-RS
■ "Emergency stop" and "mobile guard monitoring"
functions
■ Control device with one or two channels
■ 3 "N/O" safety contacts with linked contacts
6A / 250 AC
■ 1 "N/C" signalling contact
■ Level 4 according to NF.EN 954-1
KNA3-RS (45 mm)
■ Integrity check on control devices
■ Separate return loop
KZP3-RS (45 mm)
■ Four input circuits
Specifications
Type Supply voltage Connections Weight (g) Code
KNA3-XS 24 V AC/DC Screw terminals 310 85 100 036
KNAC3-XS 24 V AC/DC Spring terminals 310 85 101 036
KNA3-RS 24 V AC/DC Screw terminals 310 85 100 436
KZP3-RS 24 V AC/DC Screw terminals 410 85 100 536
40 - 260 V AC Screw terminals 310 85 100 037
40 - 260 V AC Spring terminals 310 85 101 037
115 V AC Screw terminals 410 85 100 434
230 V AC Screw terminals 410 85 100 435
10
General characteristics
Operating range -15 % / + 10 % of Un for AC
-15 % / + 15 % of Un for DC
Precision
Reset time < 25 ms
Maximum response time on emergency stop < 50 ms
Output specification
Number of safety circuits 3 "N/O" AgSnO2 contacts
Number of data circuits 1 "NC" AgSnO2 contacts
Function and use
Max. absorbed power KNA3-XS / KNA3-RS : AC 1.6 VA / DC 2 W
KZP3-RS : AC 3 VA / DC 3 W
Dielectric strength 2.95 kV according to CEI 664-1
Resistance to tracking Material group III
EMC immunity according to EN 50082-2
Radiated electromagnetic field 80 MHz to 1 GHz/900 MHz (ENV 50140/204)
KNA3-XS : 10 V/m Level 3 acc. to IEC 1000.4.3
KNA3-RS/KZP3-RS : 30 V/m Level X acc. to IEC 1000.4.3
Electrostatic discharge 8 kV in the air acc. to IEC 1000.4.2
KNA3-RS / KZP3-RS : 15 kV in the air acc. to IEC 1000.4.2
Shock waves KNA3-XS :
- Common mode 1 kV acc. to IEC 1000.4.5 KNA3-RS / KZP3-RS :
- Level 3 acc. to IEC 1000.4.5
- Common mode 2kV for 24 V and 24 V
- Common mode 4 kV for 230 V (2 kV residual current mode for KNA3-RS)
Radio frequencies in common mode KNA3-XS :
- 10 V rms Level 3 according to IEC 1000.4.6
- 150 KhZ TO 80 MHz (ENV 50141) according to IEC 1000.4.11
KNA3-RS / KZP3-RS :
- 30 Vrms Level X acc. to IEC 1000.4.6
150 kHz to 80 MHz (ENV 50141) according to IEC 1000.4.11

Dimensions
KNA3-XS Mounting - Removing KNA3-RS / KZP3-RS
113
90
68,6
118
90
22,5
68,6
Connections
KNA3-XS KNA3-RS KZP3-RS
13 23 33
A1 Y1 Y2
PWR
OUT
13 23 33 41
14 24 34 42
KNA3-XS
A2 41 42
2414 34
Y11 Y12 Y1 13 23 33
A1 X1 Y2
A2 PE Y21 Y22 42
S1 S2 41
PWR
OUT
13 23 33 41
14 24 34 42
KNA3-RS
X2 Y11Y1 14 24 34
113
90
118
13 23 33 S3 Y32 Y42
A1 S1 S2
A2 Y11 Y1 Y2 41 42
S4 Y31 Y41
PWR
OUT
13 23 33 41
14 24 34 42
KZP3-RS
Y22Y12 Y21 14 24 34
90
45
A1-A2 Power supply Control device (s)
Y1-Y2 Start / validation
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signaling contacts
A1-A2 Power supply
Y11-Y12 / Y21-Y22 Redundant inputs with
differentiated voltage for control devices
Y1-Y2 Start/validation
S1-S2 Short-circuit protection on start /
validation input
X1-X2 Return loop
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signalling contacts
A1-A2 Power supply
Y11-Y12 / Y21-Y22 Redundant inputs with
differentiated voltage for control devices
Y31-Y32 / T41-T42 Redundant inputs with
differentiated voltage for control devices
Y1-Y2 Start/validation
S1-S2 / S3-S4 Short-circuit protection on
start/validation input
13-14/23-24/33-34 "N/O" safety contacts
41-42 "N/C" signalling contacts
Principles
Control devices :
The KZP3-RS is used to obtain and maintain a category 4 level of safety for an installation with two control devices.
Depending on the degree of safety required, KNA3-XS / KNA3-RS / KZP3-RS can receive the following components as inputs :
- pushbutton for start or validation (Y1-Y2)
-emergency stop pushbuttons with
one or two contacts (A1-A2)
two contacts KNA3-RS : Y11-Y12 and Y21-Y22,
two contacts KZP3-RS : Y11-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
- position sensors (limit switches) with
one or two contacts (A1-A2)
two contacts KNA3-RS : Y11-Y12 and Y21-Y22,
two contacts KZP3-RS : Y11-Y12 / Y21-Y22 and Y31-Y32 / Y41-Y42
A positive break operation device must be used if a single channel is used.
To increase the degree of safety, one "N/C" auxiliary contact per power contactor is wired in series with the start (or validation) pushbutton, to ensure selfchecking in this part of the installation.
10
Control devices :
The KNA3 / KZP3 has three "N/O" safety contacts (13-14/23-24/33-34) and one "N/C" signalling contact (41-42). One or more control devices may be
wired up to the breaking capacity of the safety contacts : 1500 VA. However, to limit internal heating, it is advisable not to exceed 10 A thermal for all three
contacts. The signalling contact can be wired on a PLC input or integrated into a fault signalling system.
Extending the number of contacts :
The number of contacts can be extended and the breaking capacity thus increased. To do this, use the KZE3-XS.

Applications
KNA3-XS
Category 2
0V
1
13
33
23
A1 Y1 Y2
13 23 33
14 24 34
A2 42
41
14 24 34
C2
C1
24 V
4
Control device with one channel without
B
return loop
Validation
C
Two coils per contact
D
Emergency stop
E
KNA3-XS
Category 3
24 V
2
3
4
0V
Control channel with 2 channels with
B
1
2313
A1 Y1 Y2
13 23 33
14 24 34
A2 42
41
14 24 34
C1
33
C2
2
C1
C2
3
return loop
Validation
C
One coil per contact
D
Emergency stop
E
10
KNA3-RS
Category 4
+ 24 Vcc
Y11 Y1
Y12 13 33
X1
A1
4
13 23 33 41
c1
c2
c3
0V
S1 and S2 bridged for start/validation input protection
B
Emergency stop
C
41-42 to PLC or fault circuit
D
Start
E
14 24 34 42
KNA3-RS
A2
X2
23
Y2 S1 S2 41
Y22Y21 42
NC
Y11Y1 14 24 34
C1 C2 C3
KNA3-RS
Category 2
1
2
3
+ 24 Vcc
4
Y11 Y1
Y12 13 33
X1
A1
3
13 23 33 41
c1
c2
c3
0V
"Light on" reflex cells
B
41-42 to PLC or fault circuit
C
Start
D
Compulsory : S1 and S2 bridged for start/validation input
E
14 24 34 42
KNA3-RS
A2
X2
23
Y2 S1 S2 41
Y21 42
Y22 NC
Y11Y1 14 24 34
C1 C2 C3
2
1
protection

Level 4 - KZP3-RS Level 4 - KZP3-RS
+ 24 V
13
1
c1
c2
c3
0V
Start
B
S1-S2 and S3-S4 bridged for start/validation input protection
C
23 S3 Y4233
S1
A1
13 23 33 41
A2
Y11 Y1 Y2 42
Y22Y12
Y32
S2 S4 Y31 Y41
14 24 34 42
41
Y21 14 24 34
C1 C2 C3
AU1
2
AU2
2
}
1
24 V
13
23 S3 Y4233
S1
A1
0V
13 23 33 41
A2
Y11 Y1 Y2 42
Y22Y12
8
c1
c2
c3
PLC outputs
B
NO
C
Cover
D
NF
E
S1-S2 and S3-S4 bridged for short-circuit protection on the
F
Y32
S2 S4 Y31 Y41
14 24 34 42
41
Y21 14 24 34
C1 C2 C3
5
3
7
validation line
PLC input
G
Include an "N/C" contact from each power contactor in the start/
H
validation line (return loop)
Start
I
4
6

Safety relay: general characteristics
➜ Emergency stop
➜ Timed contacts
➜ Extension relay
➜ Zero speed monitoring
➜ 2-hand control
Supply
Supply voltage 24 V AC 50 / 60 Hz
On/off indication 1 power supply voltage LED
Output specification
Type Volt-free outputs
Breaking capacity (V resistive) 1500 VA
Max. breaking current 6.82 A
Max. breaking voltage 440 V AC
Electrical endurance
Mechanical life (operations)
Function and use
On/off indication 1 internal relay status LED
Operating temperature (°C) IEC 68-2-14 0 ➞ +50
Storage temperature (IEC 68-2-12) (ºC) -20 ➞ +70
Internal voltage 24 V DC
EMC immunity according to EN 50082-2
fast transients 2kV directly acc. to IEC 1000.4.4
Drop-out / short breaks / microbreaks Un-30 % for 10 ms every 1 s
Material Polycarbonate
Protection Housing IP 40
Protection Terminal IP 20
Tightening capacity
Spring terminals, 2 terminals per connection point - rigid wire
Spring terminals, 2 terminals per connection point - flexible wire
24 V DC maximum ripple 10 %
5
operations at 1500 VA resistive
10
5
5.10
operations at 500 VA resistive
7
10
4 kV directly for the 230 V <ac> version
2 Kv when coupled
Un-60 % for 100 ms every 1 s according to IEC 61496-1/97
Un-100 % for 10 ms every 100 ms
Un-50 % for 20 ms every 200 ms
Un-50 % for 500 ms every 5 s
Self-extinguishing-UL94 class VO
2 x 1.5 mm 2 multicore with ferrule
2 x 2.5 mm
2.5 mm
1.5 mm
2
solid conductor
2
2