Crouzet CTR24 Catalog Page

Electronic counters without preselection
Totalizers without preselection - LCD 24 x 48 - CTR24
Display: 8-digit LCD, height 8 mm
Powered by a lithium battery
(10
260 V
)
a
Reset on panel or external with inhibition option
Backlit model (2341-2351-2342)
Counting directions can be selected with input (2241-
2341/2251-2351)
Accessories for 50 x 25 mm cut-out
Part numbers
Type Type Functions Code
CTR24 non-backlit model 2241 Solid state input, lithium battery PNP/NPN
CTR24 model with orange backlighting
2251 Solid state input, lithium battery NPN/NPN 2242 Voltage input, lithium battery 2341 Solid state input, lithium battery PNP/NPN 2351 Solid state input, lithium battery NPN/NPN 2342 Voltage input, lithium battery
c
) or voltage
87622061 87622062 87622070 87622081 87622082 87622090
Accessories
Description Code
Adaptor for 50 x 25 mm cut-out - Fixed with screws Adaptor for 50 x 25 mm cut-out - Fixed with clips DIN rail adaptor Clip-fixing kit (supplied with the product)
26546843 26546844 26546840 26546848
General characteristics
Environmental characteristics
Consumption Connection by 8 screw terminals at rear of casing Connection capacity Fixed using bracket Degree of protection front face IP 65
Temperature limits use (°C) -10 Temperature limits stored (°C) -20 Breakdown voltage According to EN 61010-1: 2000 V / 50 Hz / 1 min Conformity to standards EN 61000-6-2 - EN 55011 class B Altitude 2000 m Certifications UL - cULus (pending) - CE Weight (g) 50
Operating characteristics
Function Impulse counter Display 8-digit LCD Height digits (mm) 8 Counting capacity -9.999.999
Inputs 2241-2341
1 slow counting input for contact closure on NPN open-collector transistor input (terminals 2-6)
1 input for high speed counting signal from voltage level (terminals 1-6) Low level High level High-speed counting 12 KHz max.
Input impedance 100 K PNP
Inputs 2251-2351
1 slow counting input for contact closure on NPN open-collector transistor input (terminals 2-6)
1 input for high speed counting signal from voltage level (terminals 1-6) Low level High level High-speed counting 7 KHz max.
Input impedance 1 M
Backlighting: 24 Vc ± 20% 50 mA
2
1.5 mm
+60+70
99.999.999 with elimination of zeros
c
4
30 V
c
0.7 V
0
c
30 V
4
42 µs PNP
3
30 V0.7 V
0
30 V
3
70 µs NPN
PNP
c
c
c
56
www.crouzet-control.com
Reset - External 2241-2341 & 2251-2351
Volt-free contact or open collector (terminals 3-6)
Inputs 2242-2342
1 input for slow counting 2 voltage levels Voltage - Terminals 1-2
10
260 V
z
Input impedance (k) 160 Slow counting 30 Hz Minimum pulse time 16 ms Low level
High level
0 10
2 V
z
260 V
z
Reset - External 2242-2342
Voltage - Terminals 2-3
Minimum pulse time 16 ms Low level
High level
0 10
2 V
z
260 V
z
Reset to zero - Panel
Reset via Inhibited: Terminals 4-6 not connected
Active: Terminals 4-6 connected
Supply
1 lithium battery - Life (years) 8
Dimensions (mm)
CTR24 Fixing strip with clip-on yoke Panel cut-out
48
24
CTR24
19,3
22x45
1
2
+0,3
- 0
22,2
+0,6
45
2,8
47,7 3
Seal
1
Fixing yoke
2
4 appliances 26546843 - Adaptor for 50 x 25 mm cut-out -
+ 0,6
3045
+ 0,3
20 22,2
Fixed with screws
40
32
56
25X50
1
26546840 - DIN rail adaptor
101
45
50,4 x 25,4
26546844 - Adaptor for 50 x 25 mm cut-out ­Fixed with clips
53
28
4
25X50
Accessory supplied with the counter
1
4
45
www.crouzet-control.com
75
83
70
57
Connections
768
30 V d c - 12 KH z
12345
+
3
5
4-30V
1
6
1
6
PNP
+
OV
4-30V
1
2
3
4
5
6
7
8
1
6
OV
4-30V
OV
1
6
4-30V
2 - 3
6
3 - 2
6
3 - 2
6
821 3 4 5 6 7
123 45 678
7KHz
30Hz
1
2
3
4
5
6
7
8
2241-2341 2241-2341 2241-2341
821 3 4 5 6 7
Fast count
PNP fast count input - Voltage PNP fast count input Transistor or 3-wire
Slow count Reset input 12 ms Enable panel reset Mode count direction 0 V common/ (BL- only 23xx) Backlighting option (only 2341) Backlighting option + 24 Vc (only 2341)
2241-2341 2241-2341 2241-2341
2-wire proximity sensor fast count input 2-wire proximity sensor fast count input Slow count input (2) or reset input (3)
2241-2341 2241-2341 2251-2351
PNP proximity sensor (for leakage current detector
1 mA)
58
Slow count input (2) or reset input (3) Slow count input (2) or reset input (3) -
Contact not supplied with power
Fast count Slow count Reset input 12 ms Enable panel reset Mode count direction 0 V common/ (BL- only 23xx) Backlighting option + (only 2351) Backlighting option + 24 Vc (only 2351)
www.crouzet-control.com
2251-2351 2251-2351 2251-2351
OV
4-30V
OV
1 - 3
2
2 - 3
6
3 - 2
6
3 - 2
6
821 3 4 5 6 7
8
10260
30Hz
10260
2
Vac/dc
Vac/dc
1 34 657
10-240V~/
2
1 - 3
2
1 - 3
10-240V~/
1
2
3
4
5
6
7
8
1 - 3
2
PNP
+
OV
10-260V
1 - 3
2
NPN
+
OV
10-260V
1 - 3
2
OV
30 V max
1
6
Fast count input NPN - Voltage
2251-2351 2251-2351 2251-2351
Slow count input (2) or reset input (3) Slow count input (2) or reset input (3) Slow count input (2) or reset input (3)
+
NPN
1
6
Fast count input NPN Transistor or 3-wire PNP proximity sensor (for leakage current detector
1 mA)
2-wire proximity sensor fast count input
Contact not supplied with power
2242-2342 2242-2342 2242-2342
Fast count AC/DC common Reset input 12 ms
Counter or reset input - Voltage Counter or reset input -
Enable panel reset count direction 0 V common/ (BL- only 23xx) Backlighting option - (only 2342) Backlighting option + 24 Vc (only 2342)
2242-2342 2242-2342 2242-2342
Counter or reset input PNP Transistor or 3-wire PNP proximity sensor (for leakage current detector < 1 mA)
Counter or reset input NPN Transistor or 3-wire PNP proximity sensor (for leakage current detector < 1 mA)
Contact supplied with power
Start/Stop or reset input: 2-wire proximity sensor R=470
current detector 1 mA
/2 W for 2-wire leakage
www.crouzet-control.com