Crouzet 87621111, 87621112, 87621115, 87621122, 87621125 Data Sheet

...
Electronic multifunction counters with preselection
Up counters / Down counters - 48 x 48 - CTR48
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Maximum input frequency 40 kHz
Simple parameter setting, configuration using text
Easy modification of presets
Scaling factor
5 A changeover relay and solid state output
Removable connectors
Backlit LCD display (orange) : 2 lines, 6 digits or
multicoloured display (green-red)
IP 65 sealed panel
Option of locking the keypad, completely or partially
(preset, programming)
Accessories for 72 x 72 or 55 x 55 cut-out,
DIN rail adaptor
Part numbers
Type Functions Preset Voltages Output Code
Orange backlight LCD display
Multicoloured LCD display (green-red)
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Preselection multi-totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer, Batch counter, Preselection totalizer
1
1
1
2
2
2
1
1
1
2
2
2
10
24 V
90
10
24 V
90
10
24 V
90
10
24 V
90
Accessories
Description Code
Adaptor for 72 x 72 mm cut-out Adaptor for 55 x 55 mm cut-out DIN rail adaptor
c 1 changeover relay,
30 V
a 1 changeover relay,
a 1 changeover relay,
260 V
c 1 changeover relay,
30 V
a 1 changeover relay,
a 1 changeover relay,
260 V
c 1 changeover relay,
30 V
a 1 changeover relay,
a 1 changeover relay,
260 V
c 1 changeover relay,
30 V
a 1 changeover relay,
a 1 changeover relay,
260 V
1 solid state
1 solid state
1 solid state
1 NO relay, 2 solid state
1 NO relay, 2 solid state
1 NO relay, 2 solid state
1 solid state
1 solid state
1 solid state
1 NO relay, 2 solid state
1 NO relay, 2 solid state
1 NO relay, 2 solid state
87621111
87621112
87621115
87621121
87621122
87621125
87621211
87621212
87621215
87621221
87621222
87621225
26546842 26546846 26546841
General characteristics
Environmental characteristics
Supply Relative humidity (no condensation) EN 60068-2-30 40/93% RLF
Altitude 0 < 2000 m Certifications UL - cULus (pending) - CE Vibration resistance in 3 axes 10-55 Hz / 1 min / XYZ EN 60068-2-6: 30 min. in each direction Connection by screw terminals Removable Protection Conforming to standard EN 60529 IP65 for panel / IP20 for connections Front panel watertight seal
Temperature limits use (°C) -20 +65 Temperature limits stored (°C) -25 Weight (g)
General characteristics
Reset to zero or to preset On panel: if not locked during programming
Minimum pulse time Impulse counter: < 15 ms
Option to protect against reset from front panel Scale factor (each input pulse is multiplied by this figure) 00.0001 99.9999
Scaling factor (each input impulse is divided by this value) 01.0000 Decimal point selectable for ease of reading 0
Sensor supply version Programming and current value backed up via EEPROM memory
Operating characteristics
Functions Preselection counter, Tachometer, Chronometer, Multi-totalizer, Batch
Number of presets 1 or 2 Display LCD with orange backlighting/Multicoloured LCD (green-red) Height digits (mm) LCD 9 Display details - 999 999
Input characteristics
Inputs 2 counter inputs
Input modes Dir: Directional
Input type Voltage or solid state High level
Low level
Solid state output characteristics
Maximum current 30 mA Max. voltage
Relay output characteristics
Changeover relay NO contact Depending on version
Maximum current 5 A Minimum current 10 mA Maximum voltage
Min. voltage Response time < 13 ms
Mechanical life (operations) Number of operations to 5 A Output modes: maintained or pulsed 0.01 99.99 s
a
10
150 c version 250 a version
Electrical: automatic, voltage or solid state (NPN or PNP depending on programming)
Chronometer: 500 μs
0.0
0.00
0.000
0.0000
0.00000 24 Vc -20/+15% 50 mA
Service life 10 years
counters, Totalizer
1 reset input, 1 gate input
AS: up/dn AA: up/up PP: phase PP2: phase 2 PP4: phase 4
8 Vc 0
10 24 Vc -20/+15%
30 Vc / 250 V 5 V
20 x 10 5 x 10
30 V
+75
2 V
30 V
z
c
/ 24 V a / 90 260 V
99.9999
999 999
c
30 V
c
c
for the c version
a
6
4
a
18
www.crouzet.com
www.crouzet.com
19
Loading...