![](/html/14/14d0/14d073e76db6db295b154e123078fe0d1e4312bf9ca0ff6264f777d132d2b40b/bg1.png)
CP
Rigid/Intermediate Grade
Conduit Fittings
INSULATED THROAT GROUNDING BUSHINGS
Features:
ɀ Resilient plastic liner resists corossion, chemicals and temperature
extremes
Rigid
Intermediate
ɀ Insuliner - ULTEM1000 rated at 150°C
ɀ 2 Set-screws provided with each fitting, locks bushings in any
desired position
ɀ Standard Finish: Zinc Plated
ɀCP
IRON – 150°C RATED
Set Screw Type – Copper Lug – For Copper Grounding
Conductors – Threadless
UL File No. E-6225
Cat. #
HGLS1C
HGLS2C
HGLS3C
HGLS4C
HGLS4-10C
HGLS5C
HGLS5-10C
HGLS6C
HGLS6-10C
HGLS7C
HGLS7-30C
HGLS7-250C
HGLS8C
HGLS8-30C
HGLS8-250C
HGLS9C
HGLS9-250C
HGLS10C
HGLS10-250C
HGLS-11C
HGLS11-250C
HGLS-12C
HGLS12-250C
Set Screw Type – Aluminum Lug – For Copper Or Aluminum
Grounding Conductors – Threadless
UL File No. E-6225
Cat. #
HGLS1
HGLS2
HGLS3
HGLS4
HGLS4-10
HGLS5
HGLS5-10
HGLS6
HGLS6-10
HGLS7
HGLS7-30
HGLS7-250
HGLS8
HGLS8-30
HGLS8-250
HGLS9
HGLS9-250
HGLS10
HGLS10-250
HGLS11
HGLS11-250
HGLS12
HGLS12-250
Trade
Lug
Size
Size
1
⁄2⍯ #4 – #14 50 500 12
3
⁄4⍯ #4 – #14 50 250 13
1⍯ #4 – #14 50 250 16
11⁄4⍯ #4 – #14 25 125 19
11⁄4⍯ #1/0 – #8 25 125 31
11⁄2⍯ #4 – #14 10 100 21
11⁄2⍯ #1/0 – #8 10 100 33
2⍯ #4 – #14 10 50 27
2⍯ #1/0 – #8 10 50 39
21⁄2⍯ #1/0 – #8 10 50 60
21⁄2⍯ #3/0 – #6 10 50 83
21⁄2⍯ 250MCM – #6 10 50 92
3⍯ #1/0 – #8 5 25 70
3⍯ #3/0 – #6 5 25 92
3⍯ 250MCM – #6 5 25 100
31⁄2⍯ #3/0 – #6 1 1 105
31⁄2⍯ 250MCM – #6 1 1 115
4⍯ #3/0 – #6 1 1 100
4⍯ 250MCM – #6 1 1 130
5⍯ #3/0 – #6 1 1 140
5⍯ 250MCM – #6 1 1 150
6⍯ #3/0 – #6 1 1 170
6⍯ 250MCM – #6 1 1 180
Trade
Lug
Size
Size
1
⁄2⍯ #4 – #14 50 500 9
3
⁄4⍯ #4 – #14 50 250 10
1⍯ #4 – #14 50 250 13
11⁄4⍯ #4 – #14 25 125 16
11⁄4⍯ #1/0 – #8 25 125 20
11⁄2⍯ #4 – #14 10 100 18
11⁄2⍯ #1/0 – #8 10 100 22
2⍯ #4 – #14 10 50 24
2⍯ #1/0 – #8 10 50 28
21⁄2⍯ #1/0 – #8 10 50 50
21⁄2⍯ #3/0 – #6 10 50 58
21⁄2⍯ 250MCM – #6 10 50 60
3⍯ #1/0 – #8 5 25 58
3⍯ #3/0 – #6 5 25 67
3⍯ 250MCM – #6 5 25 70
31⁄2⍯ #3/0 – #6 1 1 80
31⁄2⍯ 250MCM – #6 1 1 85
4⍯ #3/0 – #6 1 1 90
4⍯ 250MCM – #6 1 1 100
5⍯ #3/0 – #6 1 1 115
5⍯ 250MCM – #6 1 1 120
6⍯ #3/0 – #6 1 1 145
6⍯ 250MCM – #6 1 1 150
Unit
Qty.
Unit
Qty.
Std.
Pkg.
Std.
Pkg.
Weight
Lbs. Per
100
Weight
Lbs. Per
100
ɀ Insulated Throat Grounding Bushings
ɀ Three Piece Conduit Couplings
ɀ Conduit Bushed Nipples
THREE PIECE CONDUIT COUPLINGS
Application:
Used to join two lengths of threaded conduit. Couples conduit when
conduit can be turned.
MALLEABLE IRON (Concrete Tight)
ɀ Heavy duty casting
ɀ Standard Finish: Zinc Plated
UL File No. E-19189
Cat. # Size
190M
191
1
⁄2⍯ 25 125 23
3
⁄4⍯ 25 100 35
Unit
Quantity
Standard
Package
Weight
Lbs. Per
100
192 1⍯ 10 50 60
1
193 1
194 1
⁄4⍯ 52591
1
⁄2⍯ 5 25 167
195 2⍯ 5 5 215
1
196 2
197 3⍯ 1 5 463
198 3
⁄2⍯ 2 10 430
1
⁄2⍯ 1 5 655
199 4⍯ 1 1 800
Not UL
†
Listed
188† 5⍯ 1 1 1200
189† 6⍯ 1 1 2100
CONDUIT BUSHED NIPPLES
Use:
ɀ Use thru knockout to connect box to conduit coupling.
ɀ Use with a locknut to connect two boxes side by side or back to
back.
ɀ Use with a locknut to connect fixture housing to continuous runs.
MALLEABLE IRON Non-Insulated Threaded NPSM for rigid
conduit and IMC
UL File No. E-19189
Steel
*
† Not UL
Listed
Insulated
UL File No. E-19189
Steel
*
Cat. # Size
50*
51
1
⁄2⍯ 50 500 3
3
⁄4⍯ 25 250 8
Unit
Quantity
Standard
Package
52 1⍯ 10 100 13
1
53 1
54 1
⁄4⍯ 10 100 19
1
⁄2⍯ 10 50 30
55 2⍯ 10 50 37
1
56 2
57 3⍯ 52592
58 3
⁄2⍯ 52568
1
⁄2⍯ 1 5 130
59 4⍯ 1 5 200
60† 5⍯ 1 1 350
61† 6⍯ 1 1 425
Cat. # Size
1050*
1051
1
⁄2⍯ 50 500 3
3
⁄4⍯ 25 250 4
Unit
Quantity
Standard
Package
1052 1⍯ 10 100 11
1
1053 1
1054 1
⁄4⍯ 10 100 19
1
⁄2⍯ 10 50 30
1055 2⍯ 10 50 37
1
1056 2
1057 3⍯ 52596
1058 3
⁄2⍯ 52572
1
⁄2⍯ 1 5 113
1059 4⍯ 1 5 187
1060 5⍯ 1 1 350
1061 6⍯ 1 1 450
Weight
Lbs. Per
100
Weight
Lbs. Per
100
282