Liquidtight Conduit Fittings
Space Saver and Steel Liquidtight Fittings
SPACE SAVER LIQUIDTIGHT FITTING
Features & Benefits:
• Liquidtight, Raintight, Oiltight for protection and long life in wet,
dusty and corrosive environments
• Compact, slim diameter for tight space and neat appearance
• Male threads on the nut maximize space in box or enclosure and
provides a smooth pulling surface eliminating the need for a
CP
bushing or insulated throat fitting- saving time & money
• Reusable, long ferrule prevents pull out and tight bend conduit
"pop out"
• Hex shaped gland nut allows for easy wrenching, providing a fast
tight installation
• Split sealing ring allows sealing ring to be installed after installation
of ferrule and is reversible to ensure correct installation. Impossible
to install incorrectly!
• Grooved design on rubber gasket allows for a snug, captive fit
ensuring the gasket will not fall off during installation
• Available with optional aluminum grounding lug for easy ground
wire termination
Certifications & Compliances:
• UL Listed
• cUL Listed
Standard Materials:
• Body: Malleable Iron
• Locknut: Steel
• Gasket: Rubber
• Lug: Aluminum
Standard Finishes:
• Zinc Plated
STEEL LIQUIDTIGHT FITTING
Applications:
To terminate and seal liquidtight flexible metal conduit to a box or
enclosure. Connectors can be used with tapered thread female
entry or unthreaded knockout using the provided sealing washer
and lock nut.
Features & Benefits:
• Liquidtight, raintight, oiltight for protection and long life in wet,
dusty and corrosive environments
• Compact, slim diameter for tight space and neat appearance
• Tapered threaded male hub - NPT, maximizes space in box or
enclosure and provides a smooth pulling surface, eliminating the
need for a bushing or insulated throat fitting - saving time and
money
• Reusable, long ferrule prevents pull out and tight bend conduit
"pop out"
• Hex shaped gland nut allows for easy wrenching, providing a fast,
tight installation
• Suitable for wet locations
• RoHS Compliant
Certifications & Compliances:
• cULus Listed
• UL Standard: 514B
• NEMA: FB-1
• UL File No. E-19189
Standard Materials:
• Body: Steel
• Locknut: Steel
• Ferrule: Steel
Cat. No. Size KO Size Unit Qty Wt. Lbs./100 A B
3
SSLT38
SSLT50
SSLT75
/8"1/2"25 19 1
1
/2"1/2"25 21 1
3
/4"3/4"311
SSLT100 1" 1" 5 44 1
3
/8"13/16"
3
/8"15/16"
1
/2"19/16"
5
/8"17/8"
Cat. No. Size KO Size Unit Qty Wt. Lbs./100 A B C
SSLT38G
SSLT50G
SSLT75G
3
/8"1/2"25 23 1
1
/2"1/2"25 26 1
3
/4"3/4"361
SSLT100G 1" 1" 5 48 1
232
3
/8"13/16"3/4"
3
/8"15/16"3/4"
1
/2"19/16"3/4"
5
/8"17/8"3/4"
Standard Finishes:
• Zinc Plated
B
A
C
Straight Connectors - Steel
Conduit
Size
3
/8" LT38S LTB38S1/2"25 11.4 1"1/2"11/16"
1
/2" LT50S LTB50S1/2"25 16.3 17/16"1/2"11/4"
3
/4" LT75S LTB75S3/4"25 22.1 15/8"1/2"19/16"
1" LT100S LTB100S 1" 25 35.4 2
NonInsulated
Cat. No.
Insulated
Cat. No.KOSize
Unit
Wt. Lbs.
Qty.
Per 100 A B C
5
/16"5/8"113/16"