Liquidtight Conduit
Fittings
ɀ Combination Couplings for Coupling Liquidtight to
Threaded Rigid/IMC – Grounding Type – Aluminum Lug
ɀ Wire Mesh Grips for Liquidtight Metallic Conduit Fittings
TM
ɀ LiQuik
Liquidtight Fittings
CP
COMBINATION COUPLINGS FOR COUPLING
LIQUIDTIGHT TO THREADED RIGID/IMC – GROUNDING
TYPE – ALUMINUM LUG
Cat. #
LTR38G*
LTR50G
LTR75G
Size
3
⁄8⍯ #4-#14 25 100 24
1
⁄2⍯ #4-#14 25 100 30
3
⁄4⍯ #4-#14 25 100 35
LTR100G 1⍯ #4-#14 5 50 59
LTR125G 1
LTR150G 1
Conduit
Lug Size Unit
Qty.
1
⁄4⍯ #4-#14 5 25 81
1
⁄2⍯ #4-#14 2 20 107
LTR200G 2⍯ #4-#14 1 10 162
3
⁄8⍯ Liquidtight to 1⁄2⍯ Rigid/IMC
* For
Note: For other connector and lug combinations,
consult factory.
Copper lugs are available also. Consult factory for
details.
Std.
Pkg.
Weight
Lbs. per
100
WIRE MESH GRIPS FOR LIQUIDTIGHT METALLIC
CONDUIT FITTINGS
Application:
Wire mesh grips are used with Liquidator
liquidtight conduit fittings to prevent
conduit pullout due to stress, tension,
strain, vibration, or movement. Typical
applications include the wiring of
machine tools, motors, transformers,
food processing, equipment, robotics, or
any application that requires a flexible
liquidtight conduit connection.
WIRE MESH GRIP – DIMENSIONS
LiQuikTMLIQUIDTIGHT FITTINGS
No disassembly required! The LiQuik liquidlight fittings are quick and
easy to install in 2 steps, offering huge labor saving potential.
Available in trade sizes
3
⁄8⍯–2⍯ straight insulated.
New LiQuik Assembly Installation
1. Slide conduit inside the fully assembled
connector.
2. Turn the connector assembly or the
conduit until the ferrule threads engage
the spirals in the conduit. The pins in the
ferrule are locked inside the holes in the
connector body, preventing the ferrule from turning. Tighten the nut
against the connector.
LiQuikTMLIQUIDTIGHT FITTINGS – STRAIGHT,
NON-INSULATED
Cat. # Size Dimensions Qty 100
Conduit Unit Lbs. Per
ABCD
LTQ38
LTQ50
LTQ75
3
1
3
LTQ100 1⍯ 1⍯ 1
LTQ125 1
LTQ150 1
LTQ200 2⍯ 2⍯ 1
1
⁄8⍯
⁄2⍯
⁄4⍯
1
1
⁄2⍯ 11⁄8⍯1⁄2⍯ 11⁄8⍯ 25 15
1
⁄2⍯ 11⁄4⍯1⁄2⍯ 11⁄4⍯ 25 18
3
⁄4⍯ 11⁄4⍯1⁄2⍯ 19⁄16⍯ 25 29
⁄4⍯ 11⁄4⍯ 11⁄2⍯
⁄2⍯ 11⁄2⍯ 15⁄8⍯3⁄4⍯ 27⁄16⍯ 271
7
⁄16⍯5⁄8⍯ 113⁄16⍯ 540
11
⁄16⍯ 21⁄4⍯ 555
3
⁄4⍯3⁄4⍯ 3⍯ 199
Weight
ɀCP
Liquidtight
Cat. # Size A B Qty. Pkg. 100
Conduit Dimensions Unit Std. Per
WMG383⁄8⍯ 67⁄16⍯ 11⁄4⍯ 10 50 10
WMG50
WMG75
WMG100 1⍯ 8
WMG125 1
WMG150 1
WMG200 2⍯ 14
1
⁄2⍯ 61⁄8⍯ 17⁄16⍯ 10 50 12
3
⁄4⍯ 615⁄16⍯ 15⁄8⍯ 10 50 17
1
⁄4⍯ 103⁄4⍯ 23⁄8⍯ 21037
1
⁄2⍯ 1113⁄16⍯ 23⁄4⍯ 21056
3
⁄16⍯ 115⁄16⍯ 10 50 21
7
⁄16⍯ 35⁄16⍯ 1579
REPLACEMENT LIQUIDTIGHT FERRULES
FOR STEEL CONNECTORS ONLY.
Cat. # Size Quantity Package
FEA383⁄8⍯ 100 100
FEA50
FEA75
FEA100 1⍯ 100 100
FEA125 1
FEA150 1
FEA200 2⍯ 10 10
FEA250 2
FEA300 3⍯ 10 10
FEA350 3
FEA400 4⍯ 10 10
Conduit Unit Standard
1
⁄2⍯ 100 100
3
⁄4⍯ 100 100
1
⁄4⍯ 50 50
1
⁄2⍯ 50 50
1
⁄2⍯ 10 10
1
⁄2⍯ 10 10
Wgt.
Lbs.
LiQuikTMLIQUIDTIGHT FITTINGS – STRAIGHT,
INSULATED
Cat. # Size Dimensions Qty 100
Conduit Unit Lbs. Per
ABCD
LTQB383⁄8⍯
LTQB50
LTQB75
1
3
LTQB100 1⍯ 1⍯ 1
LTQB125 1
LTQB150 1
LTQB200 2⍯ 2⍯ 1
3
⁄8⍯ 11⁄8⍯9⁄16⍯ 11⁄8⍯ 25 16
1
⁄2⍯
⁄4⍯
1
1
⁄2⍯ 11⁄4⍯9⁄16⍯ 11⁄4⍯ 25 18
3
⁄4⍯ 11⁄4⍯9⁄16⍯ 19⁄16⍯ 25 29
⁄4⍯ 11⁄4⍯ 11⁄2⍯3⁄4⍯ 21⁄4⍯ 556
⁄2⍯ 11⁄2⍯ 15⁄8⍯
7
⁄16⍯11⁄16⍯ 113⁄16⍯ 540
13
⁄16⍯ 27⁄16⍯ 271
3
13
⁄4⍯
⁄16⍯ 3⍯ 1 100
Weight
REPLACEMENT LiQuik FERRULES
Cat. # Size 100
Conduit Lbs. Per
LTQF38
LTQF50
LTQF75
LTQF100 1⍯ 100
LTQF125 1
LTQF150 1
3
⁄8⍯ 100
1
⁄2⍯ 100
3
⁄4⍯ 100
1
⁄4⍯ 50
1
⁄2⍯ 50
LTQF200 2⍯ 10
Weight
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds