Crouse Hinds Champ Voyager nR Stainless Steel Floodlight Photometric Data

Champ®Voyager nR Stainless Steel Floodlight
PHOTOMETRICS
TM
Cl. I, Div. 2 Cl. I, Zone 2 Enclosure Type 4X IP66 UL and cUL Listed
Wet Locations Marine Locations
HPS Wide Beam Reflector
ISO FOOTCANDLE CHART
Stainless Steel Floodlight 400 W High Pressure Sodium (HPS) Catalog Number: SSMVSY400/MT Lamp: 400 W Clear HPS Lumen Rating: 50,000 Luminaire located at 0,0° Aiming Angle at 45° down from horizontal For 150 W HPS, multiply footcandles by 0.32. For 250 W HPS, multiply footcandles by 0.57.
MOUNTING FOOTCANDLE VALUES FOR
HEIGHT ISO FOOTCANDLE LINES
ABCDEF
10 40.000 20.000 8.000 4.000 2.000 0.800 15 17.778 8.889 3.555 1.778 0.889 0.356 20 10.000 5.000 2.000 1.000 0.500 0.200 25 6.400 3.200 1.280 0.640 0.320 0.128 30 4.444 2.222 0.889 0.444 0.222 0.089 35 3.265 1.633 0.653 0.327 0.163 0.065 40 2.500 1.250 0.500 0.250 0.125 0.050
MH Wide Beam Relfector
ISO FOOTCANDLE CHART
Stainless Steel Floodlight 400 W Metal Halide (MH) Catalog Number: SSFMVMY400/MT Lamp: 400 W Clear MH Lumen Rating: 34,000 Luminaire located at 0,0° Aiming Angle at 45° down from horizontal For 175 W MH, multiply footcandles by 0.42 For 250 W HPS, multiply footcandles by 0.65
MOUNTING FOOTCANDLE VALUES FOR
HEIGHT ISO FOOTCANDLE LINES
ABCDEF
10 20.000 8.000 4.000 2.000 0.800 0.400 15 8.889 3.555 1.778 0.889 0.356 0.178 20 5.000 2.000 1.000 0.500 0.200 0.100 25 3.200 1.280 0.640 0.320 0.128 0.064 30 2.222 0.889 0.444 0.222 0.089 0.044 35 1.633 0.653 0.327 0.163 0.065 0.033 40 1.250 0.500 0.250 0.125 0.050 0.025
TEMPERATURE PERFORMANCE DATA
AMBIENT DIV. 2 DIV. 2 ZONE 2 ZONE 2 WIRE 0°C WIRE 0°C TEMP. 40°C55°C40°C55°C (40°C) (55°C)
150 W HPS T1(350°C) T1(350°C) T4 T3 90°C 105°C 250 W HPS T1(350°C) T1(350°C) T4 T3 90°C 105°C 400 W HPS T1(400°C) T3 90°C— 175 W MH T1(325°C) T1(325°C) T3 T3 90°C 105°C 250 W HPS T1(325°C) T1(325°C) T3 T3 90°C 105°C 400 W MH T1(325°C) T3 105°C—
876
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
SUPPLY SUPPLY
EFFECTIVE PROJECTED AREA (EPA)
ɀ For windloading ɀ For proper pole selection AIMING ANGLE EPA
0 degrees 2.15 ft 30 degrees 1.86 ft 60 degrees 1.07 ft
2
2
2
Loading...