Champ-PakTMWall Pack
Photometric Data
Luminares
CPMV PHOTOMETRIC DATA
LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVS2W150 Lamp: 150 W/E23-1/2 Clear High Pressure Sodium (HPS)
Vertical
Angle Front Side Back
0 413 413 413
5 470 418 367
15 877 654 265
25 1343 947 169
35 1629 1135 126
45 1614 1369 68
55 2434 1267 17
65 2505 1281 0
75 2084 916 4
85 1555 322 8
90 1148 265 11
95 956 228 8
105 723 156 9
115 527 86 9
125 355 56 8
135 224 40 4
145 150 20 1
155 64 11 1
165 19 9 3
175 0 8 1
180 3 3 3
LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVM2W150-S828 Lamp: 150 W/ED28 Clear Pulse Start Metal Halide
Vertical
Angle Front Side Back
0 404 404 404
5 442 424 413
15 692 549 238
25 1345 748 136
35 1475 946 99
45 1683 1121 56
55 2105 1095 15
65 2421 1107 3
75 2230 924 0
85 1946 349 0
90 1612 280 0
95 1154 231 0
105 738 164 0
115 535 97 0
125 360 55 0
135 237 39 0
145 139 22 0
155 56 12 0
165 17 8 0
175 0 8 0
180 3 3 0
For additional photometric data, contact Cooper Crouse-Hinds.
CANDELAS
ZONAL LUMENS
Zone Lumens
0-10 42
10-20 178
20-30 371
30-40 587
40-50 760
50-60 1095
60-70 1277
70-80 1028
80-90 666
90-100 462
100-110 338
110-120 236
120-130 175
130-140 91
140-150 31
150-160 10
160-170 2
170-180 0
Total 7349
CANDELAS
ZONAL LUMENS
Zone Lumens
0-10 42
10-20 150
20-30 320
30-40 537
40-50 709
50-60 921
60-70 1218
70-80 1153
80-90 829
90-100 492
100-110 347
110-120 242
120-130 167
130-140 113
140-150 35
150-160 10
160-170 2
170-180 0
Total 7287
7L
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
871

7L
Champ-PakTMWall Pack
Luminaires
LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVF2W084 Lamps: (2) PL-T 42W/30/4P Compact Fluorescent
LUMINAIRE WITH REFRACTOR LESS WIRE GUARD
CPMVIG2W055 Lamp: 55 W Philips Induction Lamp System
For additional photometric data, contact Cooper Crouse-Hinds.
Photometric Data
Vertical
Angle Front Side Back
0 258 258 258
5 319 269 227
15 421 316 139
25 516 361 58
35 590 376 33
45 671 362 10
55 720 347 0
65 725 317 0
75 657 264 0
85 566 195 0
90 541 160 0
95 526 132 0
105 409 86 0
115 277 49 0
125 145 31 0
135 97 21 0
145 52 11 0
155 34 3 0
165 8 1 0
175 0 0 0
180 0 0 0
Vertical
Angle Front Side Back
0 241 241 241
5 290 243 199
15 352 259 110
25 414 268 45
35 427 274 28
45 475 295 12
55 462 306 3
65 439 285 0
75 364 214 0
85 330 124 1
90 309 86 2
95 276 63 2
105 206 38 2
115 121 28 1
125 80 20 2
135 55 18 1
145 32 8 1
155 21 5 2
165 5 2 0
175 0 2 0
180 1 1 1
CANDELAS
ZONAL LUMENS
Zone Lumens
0-10 26
10-20 87
20-30 155
30-40 223
40-50 286
50-60 334
60-70 357
70-80 349
80-90 309
90-100 262
100-110 188
110-120 113
120-130 64
130-140 36
140-150 16
150-160 5
160-170 0
170-180 0
Total 2810
CANDELAS
ZONAL LUMENS
Zone Lumens
0-10 23
10-20 70
20-30 114
30-40 154
40-50 194
50-60 224
60-70 228
70-80 205
80-90 169
90-100 130
100-110 86
110-120 52
120-130 34
130-140 21
140-150 9
150-160 3
160-170 1
170-180 0
Total 1717
872
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds

Champ-PakTMWall Pack
Temperature Performance Data
7L
Luminaires
TEMPERATURE PERFORMANCE DATA
SIMULTANEOUS PRESENCE
CLASS I
DIVISION 2 and ZONE 2
RESTRICTED
WATTS
HIGH-PRESSURE SODIUM
50 40
70 40
100 40
150 40* T2B T4 — — — 105
METAL HALIDE
70 40
100 40 T3 T6 — — — 90
150PS (S828) 40 T2D T5 — — — 105
MERCURY VAPOR
100 40
COMPACT FLUORESCENT
26
26 (347 V)
32
32 (347 V)
42 (120–277 V)
42 (347 V)
52 40
64 40
84 40 T2C T6 — — — 90
EMERGENCY FLUORESCENT
26 40* T3B T6 — — — 75
INDUCTION
55
85
AMBIENT
Temp °C
55
65*
55
65*
55*
55
65*
55*
40
55
40
40
55
40
40
55
40
55
55
40*
55*
40*
STANDARD
PRODUCT
T3A
T3A
T3
T3A
T3A
T3
T2C
T2C
T3C
T3C
T3C
T2C
T2B
T3B
T3A
T3
T3B
T3A
T3
T3B
T3A
T3
T3
T3
T3
T3
T2D
T2D
T2B
BREATHING
AEx nR/Ex nR
OPTION S826
T6
T6
T5
T6
T6
T5
T5
T4
T6
T6
T5
T5
T4
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
T6
CLASS II and
CLASS III
T5
T4A*
—
T5
—
—
Consult Factory for Class II Suitability with
T5
—
—
—
—
T6
—
—
T6
—
—
T6
—
—
T6
—
T6
—
T6
—
—
(Gas and Dust Present in the Same Area)
STANDARD
PRODUCT
Suitable for Class I.
Division 2/Class II
T3A/T5
T3/T4A*
—
T3A/T5
—
—
105°C Supply Wire
T3C/T5
—
—
—
—
T3B/T6
—
—
T3B/T6
—
—
T3B/T6
—
—
T3/T6
—
T3/T6
—
—
—
—
CLASS I/CLASS II
RESTRICTED BREATHING
AEx nR/Ex nR
OPTION S826
Suitable for Class I, Division 2
or Zone 2 and Class II
T5
T4*
—
T5
—
—
T5
—
—
—
—
T6
—
—
T6
—
—
T6
—
—
T6
—
T6
—
T6
—
—
SUPPLY
WIRE
TEMP °C
90
105
105
90
105
105
90
105
90
105
105
90
105
75
75
75
75
75
75
75
75
75
75
90
75
90
75
75
75
*Fuses (suffix S658) are not available for indicated light sources and ambient temperatures.
NOTE: Luminaires requiring 105°C supply wire are furnished with 3 ft. of rated wire for external wiring connection
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds