Crouse Hinds 7F Reducers Couplings and Plugs Catalog Page

Reducers, Couplings and Plugs
Cl. I, Div. 1 & 2, Groups A†,B‡,C,D Cl. II, Div. 1, Groups E,F,G Cl. II, Div. 2, Groups F,G Cl. III
Explosionproof Dust-Ignitionproof
Application:
RE and REC reducers are used in threaded heavy wall conduit systems. RE reduces conduit hubs to a smaller size. REA adapters enlarge drilled and tapped openings by 1 NPT size. REC connects two different sizes of conduit together or is used to replace a coupling and reducer in an installation. PLG plugs are used for closing threaded conduit hubs.
Features:
RE reducers have: ɀ integral bushing which prevents damage to wires ɀ full, clean cut tapered threads REC reducers have: ɀ integral bushings in both ends which prevents damage to wires ɀ funnel shaped interior to guide the wires from large to small conduit, making it easy to pull wires REA adapters have: ɀ Smooth integral bushing to protect wire insulation ɀ Knurled body for easy wrenching PLG plugs:
ɀ have clean tapered threads ɀ are available in two styles, flush
(recessed), or square head type
Standard Materials:
ɀ RE reducers – RE1108 through RE54 in steel; all others in
®
Feraloy
iron alloy
ɀ REA adapters – steel ɀ REC reducers – REC21 and
REC32 in steel; all others in
Feraloy
iron alloy
Feraloy
ɀ PLG plugs –
iron alloy
and/or steel
Standard Finishes:
ɀ
Feraloy
iron alloy – electrogalvanized and aluminum acrylic paint ɀ Steel – electrogalvanized with chromate treatment
Certifications and Compliances:
ɀ NEC/CEC:
Class I, Division 1 & 2, Groups A,B,C,D Class II, Division 1, Groups E,F,G Class II, Division 2, Groups F,G
Class III (see listings for specific Cat. Nos. suitable for Groups A or B)
ɀ UL Standard: 886 ɀ CSA Standard: C22.2 No. 30
Options:
ɀ Copper-free aluminum – add suffix SA to Cat. No.
RE
Size Cat. #
1
2-1⁄8 RE1108*
1
2-1⁄4 RE1208*
1
2-3⁄8 RE1308
3
4-1⁄2 RE21†
1
2 RE31†
1–
3
4 RE32†
1–
1
4-1⁄2 RE41†
1
1
4-3⁄4 RE42†
1
1
4-1 RE43†
1
1
2-1⁄2 RE51†
1
1
2-3⁄4 RE52†
1
1
2-1 RE53†
1
1
2-11⁄4 RE54†
1
1
2 RE61†
2–
3
4 RE62†
2– 2-1 RE63†
1
4 RE64†
2-1-
1
2 RE65†
2-1-
1
2-1 RE73†
2
1
2-11⁄4 RE74†
2
1
2-11⁄2 RE75†
2
1
2-2 RE76†
2 3-1 RE83†
1
4 RE84†
3-1-
1
2 RE85†
3-1­3-2 RE86†
1
2 RE87†
3-2-
1
2-2 RE96†
3
1
2-21⁄2 RE97†
3
1
2-3 RE98†
3 4-2 RE106†
1
2 RE107†
4-2­4-3 RE108†
1
2 RE109†
4-3­5-4 RE01210 6-5 RE01412
REC
Large Small Hub Hub Size Size Cat. #
3
4 1 1
1
4
1
1
4 1 REC43
1
1
2
1
1
2 1 REC53
1
1
2 11⁄4 REC54
1 2 2 1 REC603 21 21
1
2 11⁄2 REC75
2 3 2 REC86
1
2 21⁄2 REC97*
3
1
2 REC21†
1
2 REC31†
3
4 REC32
3
4 REC42
3
4 REC52
3
4 REC602
1
4 REC604
1
2 REC605
4 3 REC108* 5 4 REC01210*
REA
Male Female Hub Hub Size Size Cat. #
1
2
3
4 1 REA23† 11
3
4 REA12†
1
4 REA34†
Recessed
Square Head
PLG
Recessed
Size Cat. #
1
4 PLG28†
1
2 PLG1†
3
4 PLG2†
1 PLG3†
1
4 PLG4‡
1
1
2 PLG5‡
1 2 PLG6‡
1
2 PLG7‡
2 3 PLG8‡
1
2 PLG9‡
3 4 PLG10‡
Square Head
1
2 PLG15†
3
4 PLG25†
1 PLG35†
1
4 PLG45‡
1
1
2 PLG55‡
1 2 PLG65‡
1
2 PLG75
2 3 PLG85
1
2 PLG95
3 4 PLG105
Suitable for use in Class I, Groups A and
B areas.
Suitable for use in Class I, Group B areas.
* Not available in aluminum.
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
169