Crouse Hinds 6L EVF Series Fluorescent Luminaires Catalog Page

EVF Series Fluorescent Luminaires
Application:
EVF luminaires are used in areas where hazardous fumes, gases, or dusts are present. EVF luminaires with S718 option are designed specifically for use inside paint spray booths where hazardous fumes, gases, and paint residue are present. This includes powder paint process areas. EVF luminaires with S718 option are also suitable for use in wet locations.
Features:
All EVF luminaires
ɀ Provide cool, even light with natural color rendition ɀ Reduce relamping schedule (long lamp life) ɀ Continuous and uniform illumination made possible by mounting end to end (no space needed between luminaires for relamping) ɀ No special tools required for relamping. Threaded lamp tube cover provides quick and easy access for relamping ɀ Threaded joints on lamp tube and wiring chamber covers permit easy access for lower maintenance costs ɀ Reflectors can be removed or replaced with only a screwdriver ɀ Easy to install. Factory sealed and wired luminaire facilitates installation ɀ Standard electronic ballast for 32 watt and 40 watt rapid start luminaires. ɀ Standard energy efficient ballast for 40 watt slimline, 60 watt and 110 watt luminaires. ɀ Low temperature ballast is supplied as standard on 32 watt T8 (0°F), 40 watt slimline (0°F); 60 watt and 110 watt luminaires(–20°F). ɀ All exposed hardware is stainless steel for maximum protection against corrosion, and for longer luminaire life ɀ Copper-free aluminum construction throughout means lighter luminaire weight, easier installation, and excellent corrosion resistance ɀ All exterior materials are non­sparking ɀ Type P ballasts furnished in compliance with NEC ɀ Heavy-duty glass lamp tubes provide maximum strength and impact resistance to protect lamps
ɀ
Cl. I, Div 1, Groups C,D
ɀ
Cl. I, Zone 1 Group IIB
ɀ
Cl. II, Div 1, Groups E,F,G
ɀ
Cl. III, Simultaneous Presence
3-lamp 2-lamp with angle reflector
ɀ
Paint Spray (Suffix S718)
ɀ
Wet Locations (Suffix S718)
ɀ
3,3R, IP54 (Suffix S718)
EVF
Furnished For Hub Line Volts 1-Lamp 2-Lamp 3-Lamp 4-Lamp Use With Size 60 Hz.* Cat. # Cat. # Cat. # Cat. #
32 watt, T-8 medium3⁄4⍯ 120-277 EVF21029/UNV EVF22029/UNV EVF23029/UNV EVF24029/UNV Bi-pin 265MA lamps
40 watt, T-12 medium 3/4⍯ 110-125 EVF21082 EVF22082 EVF23082 EVF24082 Bi-pin rapid start 3/4⍯ 277 EVF21087 EVF22087 EVF23087 EVF24087 430MA lamps† 3/4⍯ 347 EVF21089/347 EVF22089/347 EVF23089/347 EVF24089/347
40 watt, T-12 single pin, slimline 425MA lamps
60 watt, T-12 recessed contact, 800MA lamps†
110 watt, T-12 recessed contact, 1500MA lamps†
* For 220 volt 50 hz, 240 volt 50 hz or 240 volt 60 hz operation change the last ‘‘2’’ in the 120 volt 60 hz catalog number to a ‘‘9’’ and add
‘‘/220 50’’, ‘‘/240 50’’ or ’’/240 60’’ respectively. ie. For a 2 lamp, 40 watt rapid start luminaire for 220 volt 50 hz operation order an EVF22089/220 50.
50 Hz not available.
EVF luminaires with S718 option
ɀ All joints sealed ɀ Inside paint booth mounting
capabilities provide greater flexibility in luminaire placement, avoids necessity of complicated design and installation work, and improves task lighting control ɀ Smooth simple design makes it easy to remove any accumulated deposits of paint residue
Mounting Accessories:
Various hazardous area fittings are used to mount EVF luminaires. The fittings shown on page 859 support the unwired (relamping) end. For the wired (ballast) end any of the luminaire hangers for hazardous locations (listed in Section 7L) can be used. CPS conduit outlet bodies with hub covers (listed in Section 4F) are also suitable
3
⁄4⍯ 347 EVF21029/347 EVF22029/347 EVF23029/347 EVF24029/347
3
⁄4⍯ 110-125 EVF21032 EVF22032 EVF23032 EVF24032
3
⁄4⍯ 277 EVF21037 EVF22037 EVF23037 EVF24037
3
⁄4⍯ 347 EVF21039/347 EVF22039/347 EVF23039/347 EVF24039/347
3
⁄4⍯ 110-125 EVF21062 EVF22062 EVF23062 EVF24062
3
⁄4⍯ 277 EVF21067 EVF22067 EVF23067 EVF24067
3
⁄4⍯ 347 EVF21069/347 EVF22069/347 EVF23069/347 EVF24069/347
3
⁄4⍯ 110-125 EVF21072 EVF22072 EVF23072 EVF24072
3
⁄4⍯ 277 EVF21077 EVF22077 EVF23077 EVF24077
3
⁄4⍯ 347 EVF21079/347 EVF22079/347 EVF23079/347 EVF24079/347
Options:
ɀ For suitability for wet locations and locations having deposits of readily combustible paint residue – add Cat. No. Suffix S718
Corro-free
ɀ
coat – add Cat. No. Suffix S752 ɀ With 45° angle reflectors in lieu of straight down reflectors – add Cat. No. Suffix S369 ɀ Clear disposable polyester tube wrap – consult Cooper Crouse-Hinds
ɀ Fused – add suffix S658‡ ɀ Furnished with lamps - add
suffix S714. ɀ Low temperature electromagnetic ballast for 40 watt T12 rapid start luminaires rated for 0°F - add suffix BY.
TM
epoxy powder
Size Ranges:
ɀ 1, 2, 3, and 4-lamp
Electrical Rating
Standard Materials:
ɀ Copper-free aluminum except sheet aluminum reflectors
Standard Finishes:
ɀ Natural except reflectors ɀ Reflectors – white epoxy
powder coat
Certifications and Compliances:
ɀ NEC and CEC:
Class I, Division 1 Group C, D Class I, Zone 1 Group IIB Class II Group E, F, G Class III Simultaneous Presence (Cl. I and Cl. II) Paint Spray (S718)
ɀ UL Standards:
844 Hazardous (Classified) Locations 1598 Luminaires
ɀ CSA Standards:
C22.2 No. 137
Ranges:
ɀ 32 to 110 watts
Temperature Performance Data: (Based on 40°C Ambient)
Lamp Class I/Class II/Zone 1 Supply Type 1 Lamp 2 Lamp 3 Lamp 4 Lamp Wire
32/40W T5 T5 T5 T5 75°C 60W T5 T5 T5 T5 75°C 110W T4 T4 T4 T4 90°C
When ordering fuses for luminaires,
option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number.
858
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds