Crouse Hinds 5F TUCF Series Barrier Gland Catalog Page

TUCF Series Barrier Gland
Atex and CENELEC Range
TUCF
Certifications and Compliances
ɀ ATEX E Exd I & IIC with SIRA 03ATEX1552X ɀ Standards EN50014, EN50018 and EN50281-1-1:1998 ɀ IP66 and IP68 at 100 meters ɀ DTS01 1991 deluge ɀ CSA Exd I & IIC ɀ Type 4X ɀ Zone 1 and Zone 2 ɀ Ignitable dusts, Zones 21 and 22 ɀ GOST R-Exd I & IICU ɀ Mining Equipment Group I, M2
ATEX and CENELEC E Exd I & IIC ATEX I M2 II 2 GD Ignitible dusts, Zones 21 and 22 CSA Exc I & IIC Class I, Zone 1 or 2 Hazardous Areas Type 4X, IP66/68 DTS01 1991 Deluge
Application
The TUCF series is a flameproof E Exd compound filled barrier cable gland for use in Zone 1 or 2 hazardous areas with ATEX/CENELEC equipment and unarmoured cable. Also, for use in Exd and Exe hazardous areas with CSA equipment and unarmoured cable. The TUCF series will maintain the flameproof Exd integrity of any volume enclosure with an internal ignition source for all gas groups when used with any unarmoured cable types.
Features:
All TUCF Cable glands:
ɀ are available in all brass or all stainless steel construction. ɀ are provided with sealing compound that cures in 4 hours at 21°C. ɀ maintain Flameproof Exd methods of explosion protection. ɀ provide a secondary seal on the outer sheath offering IP66/68 and
Type 4X protection.
ɀ provide an entry thread seal (metric threads only). ɀ meet DTS011991 deluge requirements. ɀ may be terminated 1 hour after creation of seal. ɀ may be energized 4 hours after creation of seal. ɀ are available with metric or NPT threads. ɀ are available with optional nickel-plate finish. ɀ are provided with silicone seals, temperature range -60°C to +85°C.
Design Data (millimeters)
Gland A B
Size (across corners)
16 28.0 16
20S 28.0 16
20 33.0 16 25 41.4 16 32 50.6 16 40 60.5 16
50S 71.5 16
50 71.5 16
63S 88.0 19
63 88.0 19
75S 99.0 19
75 99.0 19 80 115.2 25 85 115.2 25 90 125.7 25
100 125.7 25
86
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
TUCF Series Barrier Gland
ATEX and CENELEC E Exd I & IIC ATEX I M2 II 2 GD Ignitible dusts, Zones 21 and 22 CSA Exc I & IIC Class I, Zone 1 or 2 Hazardous Areas
Atex and CENELEC Range
Type 4X, IP66/68 DTS01 1991 Deluge
Ordering Information
Build your catalog number from the information below. All catalog numbers consist of three main sections:
1. Select the Gland Type based on material required (i.e., TUCFB)
2. Select the Gland Size based on cable specifications (i.e., 20S)
3. Specify Thread Size (i.e., 075NPT) (Available sizes listed in step 2)
Ordering example:
TUCFB/20S/075NPT
Step 1: Select Gland Type from Table below:
Gland Types
Gland Type Description
TUCFB Compound filled universal gland for steel wire, steel braid & steel tape w/ silicone seal -
TUCFS Compound filled universal gland for steel wire, steel braid & steel tape w/ silicone seal -
For optional nickel-plate finish on brass glands add suffix /NP after Gland Type (i.e., TUCFB/NP). For reduced bore gland add ‘‘R’’ at the end of Gland Type (i.e., TUCFBR). For optional poly-bagged kit including gland, locknut, earth tag, sealing washer and PVC shroud, add ‘‘K1’’ at the end of Gland Type (i.e., TUCFBK1).
Brass construction
Stainless steel construction
Step 2: Select Gland Size based on Cable Size from Table below:
Cable Sizes
Gland No. of Over Inner Shroud
Size Metric NPT Cores Cores Sheath Min Max Size
16 M20
20S M20
20 M20 25 M25 32 M32 1or 11⁄4 50 23.5 26.3 18.1 26.3 EL46 40 M40 11⁄4or 11⁄2 80 28.8 32.2 22.6 32.2 EL55
50S M50 2 100 34.2 38.2 28.2 38.2 EL65
50 M50 2 100 39.4 44.1 33.1 44.1 EL65
63S M63 21⁄2 120 44.8 50.1 39.3 50.1 EL80
63 M63 21⁄2 120 50.0 56.0 46.7 56.0 EL80
75S M75 3 140 55.4 62.0 52.3 62.0 EL90
75 M75 3 140 60.8 68.0 58.0 68.0 EL90 80 M80 x 2 3or 31⁄2 160 64.4 72.0 61.9 72.0 L104 85 M85 x 2 3or 31⁄2 180 69.8 78.0 69.1 78.0 L104 90 M90 x 2 31⁄2or 4 200 75.1 84.0 74.1 84.0 L114
100 M100 x 2 31⁄2or 4 220 80.5 90.0 81.8 90.0 L114
(Dimensions are all in millimeters)
GLAND SEAL RANGE
Available Cable Inner
Entry Threads Sheath/Cores [C] Standard
Max Max Max
1
2or 3⁄4 7 8.4 8.4 3.4 8.4 L24
1
2or 3⁄4 8 10.4 11.7 4.8 11.7 L24
1
2or 3⁄4 14 12.5 14.0 9.5 14.0 EL30
3
4or 1 25 17.8 20.0 11.7 20.0 EL38
Cable Outer Sheath [D]
Step 3: Specify Thread Size from Table below: Metric Thread Sizes
Thread Size Add to Catalog Number
M16 M16 M20 M20 M25 M25 M32 M32 M40 M40 M50 M50 M63 M63 M75 M75 M80 M80 M85 M85 M90 M90
M100 M100
NPT Thread Sizes
Thread Size Add to Catalog Number
1
2NPT 050NPT
3
4NPT 075NPT
1NPT 100NPT
1
4NPT 125NPT
1
1
2NPT 150NPT
1
2NPT 200NPT
1
2NPT 250NPT
2
3NPT 300NPT
1
2NPT 350NPT
3
4NPT 400NPT
—— ——
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
87