Crouse Hinds 35-150W LMV Series Photometric Data

35-150W LMV Series
Photometric Data
Champ®H.I.D. Luminaires
Lamp: 100W/E-17 high pressure sodium (HPS) Total bare lamp lumens: 9500
To determine number and placement of luminaires, see Lighting Selector Guide, pages 665 to 689. NOTE: All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Cooper Crouse-Hinds for additional photometric data on any
Champ
Series luminaire.
Luminaire with Globe and Dome Reflector
Multipliers (for use with
candlepower curves only).
Luminaire Series
LMVS 35 0.24
Luminaire spacing ratio: 2.0
Con-
Lamp
version
Watts
Factors
50 0.42 70 0.67 150 1.68
Coefficient of Utilization
Effective Floor Cavity Reflectance 20%
% Reflectance Room Cavity Ratio Eff. Cell Wall 12345
80 30 .691 .579 .487 .408 .346
70 30 .676 .568 .479 .403 .340
50 30 .647 .548 .464 .390 .332
30 30 .623 .529 .450 .379 .322
10 30 .598 .510 .436 .367 .341
0 0 .568 .471 .391 .319 .263
% Reflectance Room Cavity Ratio Eff. Cell Wall 678910
80 30 .300 .259 .225 .199 .165
70 30 .295 .255 .223 .196 .165
50 30 .288 .248 .217 .192 .161
30 30 .280 .243 .210 .186 .157
10 30 .272 .237 .206 .182 .152
0 0 .223 .187 .158 .136 .107
50 .722 .628 .545 .473 .413
10 .663 .537 .441 .358 .296 50 .705 .613 .534 .463 .403
10 .650 .531 .436 .355 .293 50 .671 .585 .511 .442 .387
10 .627 .514 .426 .349 .289 50 .641 .560 .489 .424 .371
10 .605 .501 .416 .342 .284 50 .614 .537 .470 .407 .356
10 .584 .488 .407 .335 .279
50 .366 .324 .288 .261 .226
10 .253 .215 .180 .156 .127 50 .358 .318 .282 .256 .221
10 .249 .212 .179 .156 .126 50 .343 .305 .271 .246 .214
10 .246 .209 .177 .154 .124 50 .330 .292 .261 .237 .206
10 .242 .205 .175 .152 .122 50 .317 .282 .251 .228 .199
10 .238 .202 .172 .149 .120
Isofootcandle Chart: Luminaire with Globe and Dome Reflector
Isofootcandle Chart: Luminaire with Globe and 30° Angle Reflector
Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights.
Height (Ft.) Factor Height (Ft.) Factor
6 2.78 14 0.51 8 1.56 16 0.39 12 0.70
742
US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright©2006 Cooper Crouse-Hinds
Loading...