Cross Technologies 1582-03 Instruction Manual

Instruction Manual Model 1582-03
Data Switch
April 2009 Rev C
SWITCH A
MODEL 1582
1 2
AUTO
CROSS TECHNOLOGIES, INC.
ON­LINE
MANUAL SELECT
REM
ON­LINE
ALM
CH 1
CH 2
ALM
MAN
RESET
SWITCH B
AUTO
ON­LINE
MANUAL SELECT
REM
ON­LINE
ALM
CH 1
CH 2
ALM
MAN
RESET
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc.,
but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc.
for purposes of operating the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
INSTRUCTION MANUAL
MODEL 1582-03 Data Switch
TABLE OF CONTENTS PAGE
Warranty 2
1.0 General 3
1.1 Equipment Description 3
1.2 Technical Characteristics 4
2.0 Installation 5
2.1 Input & Output Connectors 5
2.2 Controls & Indicators 7
2.3 Mechanical 8
2.4 Time Out Alarm 8
2.5 Installation/Operation 8
2.6 Environmental Use Information 10
WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.
All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
E-MAIL info@crosstechnologies.com
1582-03 Manual, Rev. C Page 2 4/13/09
MODEL 1582-03 Data Switch
1.0 General
1.1 Equipment Description
The 1582-03 Data Switch provides Auto, Manual, or Remote relay switching between CH1 and CH2 RS232C
data signals on pins 2 or 3, selectable, with pin 5 ground and the other pins of the DB9 connectors not connected. Alarm conditions are either if data is lost for a preset 1 to 9 minutes on CH1, CH2 or with external alarm contact closures. The 1582-04 has two switches in one chassis. Switching logic can be jumper selected as follows:
1. CH1 Prime Mode - Switches from CH1 to the CH2 only if CH1 alarms and CH2 is good. Switches back when CH1 no longer in alarm or both CH1 and CH2 are bad.
2. Latch to CH2 Mode - Latches to CH2 if CH1 alarms and CH2 is good. Return to CH1 only when Manual Reset switch is pushed or Remote Reset pin is grounded and if no alarm on CH1.
3. Minimum AUTO switching, Initial Channel Select ( ICS) Mode - Switch stays on channel last selected by Manual or Remote selection after return to AUTO. AUTO switching occurs only if current channel alarms and other channel is clear.
If power is lost or first applied (as alarms at power up dictate), CH1 is selected. The Manual Select switch and
(when in AUTO) contact closures to Remote Select pins, select CH1 or CH2 independent of alarms. LEDs and closures indicate alarms and switch selection of CH1 or CH2 and REMOTE or MANUAL operation. Redundant power supplies.
SWITCH A
MODEL 1582
1 2
AUTO
CROSS TECHNOLOGIES, INC.
ON­LINE
MANUAL SELECT
REM
ON­LINE
ALM
CH 1
CH 2
ALM
MAN
RESET
SWITCH B
AUTO
ON­LINE
MANUAL SELECT
REM
ON­LINE
ALM
CH 1
CH 2
ALM
MAN
RESET
FRONT PANEL
AC1
AC2
DATA 2
1
J8
GND
DATA 1
DATA OUT
J103
J107
J106
FIGURE 1.1 Model 1582-03 Front and Rear Panels
SELECTED DATA
1582-03 BLOCK DIAGRAM
CH 1 DATA
CH 2 DATA
AUTO
CH 1
CH 2
CONTROL LOGIC
ALM
DET CH2
MANUAL SELECT
1 2 REM.
1 2 ALM
1 2 1 OR 2 DATA ALARM
REM. SW RST
1 2 MON
M R A E N M
1582-03 Manual, Rev. C Page 3 4/13/09
1.2 Technical Specifications
Data Characteristics
Input/Output RS232C Data rate 128 kbps, maximum Connectors, data DB9, female Pin Switched 2 Ground pin 5
Switch Characteristics
Type Relay, non-blocking Isolation >40 dB to 128 kbps Switch after data loss 1 to 9 minutes (factory set) Switch time 10 milliseconds after command to switch Contact resistance 10, < 1 typ Configuration SPDT Connectors, data DB9, Female Conn, alarm/controls Barrier Strip
Controls
MANUAL SELECT Manually select CH1, CH2, or AUTO operation. If operating in the ICS mode,
the last channel manually selected (CH1 or CH2) will be the initial channel if
both channel alarms are clear or both channels are in alarm. SWITCH RESET Resets switch to CH1 if it is good and switch is in the latch mode, Also Resets REMOTE by returning operation to AUTO
Indicators, LEDs
CH1 ON-LINE Turns green when Channel 1 is selected CH2 ON-LINE Turns green when Channel 2 is selected MANUAL Turns red when the Manual Select switch manually selects channel 1 or 2. ALARM CH1 Turns red when CH1 data alarms or on external alarm input (closure or open, selectable) ALARM CH2 Turns red when CH2 data alarms or on external alarm input (closure or open, selectable) POWER 1 Turns green when power is applied to AC1 input on the rear panel POWER 2 Turns green when power is applied to AC2 input on the rear panel REMOTE Turns amber when REMOTE control is active
Other
Mechanical 19 inch standard chassis 1.75”high X 12” deep Power Redundant power supplies;100-240 ±10% VAC, 47 - 60Hz, 2A max
*Specifications subject to change without notice 1582-03 Manual, Rev. C Page 4 4/13/09