P/N 197220100A (0905)
Table of Contents
Important Safety Instructions ................................................ 2 Reversing door .............................................................. 14-15
Pre-installation Requirements ................................................ 2 Accessories/Replacement parts ............................................ 16
Installation Requirements .................................................. 3-7 Francais .............................................................................. 17
Installed Dimensions ............................................................. 8 Espahol............................................................................... 32
Installation Instructions ................................................... 9-13
Important Safety Instructions
Foryour safety the information in this manual must be followed to minimize the risk of fire or explosion or to
prevent property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Recognize safety symbols, words and labels
Safety items throughout this manual are labeled with a
WARNING or CAUTION based on the risk type as described:
- RISK OF FIRE - Read all of the following instructions before installing and using this appliance:
• Destroy the carton and plastic bags after the dryer is unpacked. Children might use them for play. Cartons covered with
rugs, bedspreads, or plastic sheets can become airtight chambers causing suffocation. Placeall materials in a garbage
container or make materials inaccessible to children.
Clothes dryer installation and service must be performed by a qualified installer, service agency or the gas supplier.
Install the clothes dryer according to the manufacturer's instructions and local codes.
The electrical service to the dryer must conform with local codes and ordinances and the latest edition of the National
Electrical Code, ANSI/NFPA70, or in Canada, the Canadian electrical code C22.1 part 1.
The gas serviceto the dryer must conform with local codes and ordinances and the latest edition of the National Fuel Gas
Code ANSI Z223.1, or in Canada, CAN/ACG B149.1-2000.
The dryer is designed under ANSI Z 21.5.1 or ANSI/UL2158 - CAN/CSA C22.2 No. 112 (latest editions) for HOME USE
only. This dryer is not recommended for commercial applications such as restaurants, beauty salons, etc.
Do not install aclothes dryer with flexible plastic venting material. Flexible venting materials are known to collapse, be eas-
ily crushed and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
The instructions in this manual and all other literature included with this dryer are not meant to cover every possible
condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and
maintaining any appliance.
may cause serious body harm, death or property damage.
_This symbol alerts you to situations that may
cause bodily injury or property damage.
This symbol alerts you to situations that
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Clear the room, building or area of all occupants.
Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Save these instructions for future reference.
Pre-lnstallation Requirements
Tools and materials needed for installation:
Adjustable pliers
Phillips, straight, & square bit screw-
drivers
Adjustable wrench
Pipe wrench for gas supply (gas dryer)
LP-resistant thread tape (for natural
gas or LPsupply, gas dryer)
Carpenter's level
External vent hood
4-inch (10.2 cm), rigid metal or semi-
rigid metal exhaust duct work
3-wire or 4-wire 240 volt cord kit
(electric dryer)
4 in. (10.2 cm) clamp
Gas line shutoff valve (gas dryer)
1/2NPT union flare adapters (x2) and
flexible gas supply line (gas dryer)
Metal foil tape (not duct tape)
Electrical System Requirements
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered gen-
erators, solar powered generators, wind powered generators or any other generator other than the local utility company is not
recommended.
Electrical requirements for electric dryer
CIRCUIT- Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWERSUPPLY- 3-wire or 4-wire, 240 volt, single phase, 60 Hz, Alternating Current.
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada.
Only a 4-conductor cord shall be used when the appliance is installed in a location where grounding through the neutral
conductor is prohibited. Grounding through the neutral link is prohibited for: (1) new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral.
OUTLETRECEPTACLE- NEMA 10-30R or NEMA 14-30R receptacle to be located so the power supply cord isaccessiblewhen the
dryer is in the installed position.
GROUNDING CONNECTION - See "Grounding requirements" in Electrical Installation section.
3-WIRE POWER SUPPLY CORD KIT (not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor power supply cord
NEMA 10-30 type SRDTrated at 240 volt AC minimum,
30 amp, with 3 open end spade lug connectors with
upturned ends or closed loop connectors and marked
for use with clothes dryers. For 3-wire cord connection
instructions see ELECTRICALCONNECTIONSFORA
3-WIRE SYSTEM.
Electrical requirements for gas dryer
CIRCUIT- Individual, properly polarized and grounded 15
amp. branch circuit fused with 15 amp. time delay fuse or
circuit breaker.
POWERSUPPLY- 2-wire, with ground, 120 volt, single phase,
60 Hz, Alternating Current.
POWERSUPPLYCORD - The dryer is equipped with a 120 volt
3-wire power cord.
GROUNDING CONNECTION - See "Grounding requirements"
in Electrical Installation section.
4-WIRE POWER SUPPLY CORD KIT (not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor power supply cord
NEMA 14-30 type SRDTor ST(as required) rated at 240
volt AC minimum, 30 amp, with 4 open end spade lug
connectors with upturned ends or closed loop connectors
and marked for usewith clothes dryers. For4-wire cord
connection instructions see ELECTRICALCONNECTIONS
FORA 4-WIRE SYSTEM.
Dryers manufactured for sale in Canada have factory-
installed, 4-wire power supply cord (NEMA 14-30R).
Do not, under "_
any circumstances,
cut, remove,
or bypassthe
,_grounding prong. _,
Powercord with
3-prong grounded plug
]
Gas supply requirements
- EXPLOSION HAZARD - Uncoated copper
tubing will corrode when subjected to natural gas, causing
gas leaks. Use ONLY black iron, stainless steel, or plastic-coat-
ed brass piping for gas supply.
1. Installation MUST conform with local codes, or in the
absence of local codes, with the National FuelGas Code,
ANSI Z223.1 (latest edition).
2. The gas supply line should be 1/2 inch (1.27 cm) pipe.
3. If codes allow, flexible metal tubing may be used to
connect your dryer to the gas supply line. The tubing
MUST be constructed of stainless steel or plastic-coated
brass.
4. The gas supply line MUST have an individual shutoff valve.
Exhaust system requirements
Use only 4 inch (10.2 cm) diameter (minimum) rigid or flexible
metal duct and approved vent hood which has a swing-out
damper(s) that open when the dryer is in operation. When
the dryer stops, the dampers automatically closeto prevent
drafts and the entrance of insects and rodents. Toavoid
restricting the outlet, maintain a minimum of 12 inches (30.5
cm) clearance between the vent hood and the ground or any
other obstruction.
5. A 1/8 inch (0.32 cm) N.RT. plugged tapping, accessible
for test gauge connection, MUST be installed immediately
upstream of the gas supply connection to the dryer.
6. The dryer MUST be disconnected from the gas supply
piping system during any pressure testing of the gas
supply piping system at test pressures in excess of 1/2 psig
(3.45 kPa).
7. The dryer MUST be isolated from the gas supply piping
system during any pressure testing of the gas supply
piping system at test pressures equal to or lessthan 1/2
psig (3.45 kPa).
8. Connections for the gas supply must comply with the
Standard for Connectors for Gas Appliances, ANSI Z21.24.
- FIRE HAZARD - Failure to follow these in-
structions can create excessive drying times and fire hazards.
The following are specific requirements for
proper and safe operation of your dryer.
- FIRE HAZARD - Do not install a clothes
dryer with flexible plastic or metal foil venting materials.
Flexible venting materials are known to collapse, be easily
crushed and trap lint. These conditions will obstruct clothes
dryer airflow and increase the risk of fire.
If your present system is made up of plastic duct or metal foil
duct, replace it with a rigid or semi-rigid metal duct. Also,
ensure the present duct isfree of any lint prior to installing
dryer duct.
Correct
ii
Correct
'1i
Incorrect
'1ii
Incorrect
Exhaust system requirements, continued
- FIRE HAZARD - A clothes dryer must be
exhausted outdoors. Do not exhaust dryer into a chimney, a
wall, a ceiling, an attic, a crawl space or any concealed space
of a building. A clothes dryer produces combustible lint. If
the dryer is not exhausted outdoors, some fine lint will be
expelled into the laundry area. An accumulation of lint in any
area of the home can create a health and fire hazard.
The dryer must be connected to an exhaust outdoors.
Regularly inspect the outdoor exhaust opening and remove
any accumulation of lint around the outdoor exhaust opening
and in the surrounding area.
- FIRE HAZARD -
• Do not allow combustible materials (for example: clothing,
draperies/curtains, paper) to come in contact with exhaust
system. The dryer MUST NOT be exhausted into a chim-
ney, a wall, a ceiling, or any concealed space of a building
which can accumulate lint, resulting in a fire hazard.
Do not screen the exhaust ends of the vent system, or use
any screws, rivets or other fasteners that extend into the
duct to assemble the exhaust system. Lint can become
caught in the screen, on the screws or rivets, clogging the
duct work and creating a fire hazard as well as increasing
drying times. Use an approved vent hood to terminate
the duct outdoors, and sealall joints with metal foil tape.
All male duct pipe fittings MUST be installed downstream
with the flow of air.
- FIRE HAZARD - Exceeding the length of
duct pipe or number of elbows allowed in the "MAXIMUM
LENGTH" charts can cause an accumulation of lint in the ex-
haust system. Plugging the system could create a fire hazard,
as well as increase drying times.
MAXIMUM LENGTH
of 4" (10.2cm) Rigid Metal Duct
VENT HOOD TYPE
o
o_
0
1
2
3
4
o
(lO.2cm)
(Preferred)
4"
64 ft. (19.5 m)
52 ft. (15.9 m)
44 ft. (13.5 m)
32 ft. (9.8 m)
28 ft. (9.5 m)
Iouvered
2.5"
(6.35cm)
48 ft. (14.6 m)
40 ft. (12.2 m)
32 ft. (9.8 m)
24 ft. (7.3 m)
16 ft. (4.9 m)
- FIRE HAZARD -
Do not install flexible plastic or flexible foil venting mate-
rial.
If installing semi-rigid venting, do not exceed 8 ft. (2.4 m)
duct length.
Install male fittings in correct direction:
CORRECT INCORRECT
Exhaust system requirements, continued
In installations where the exhaust system is not described in
the charts, the following method must be used to determine
if the exhaust system is acceptable:
1. Connect an inclined or digital manometer between the
dryer and the point the exhaust connects to the dryer.
2. Set the dryer timer and temperature to air fluff (cool
down) and start the dryer.
3. Readthe measurement on the manometer.
4. The system back pressure MUST NOT be higher than
0.75 inches of water column. If the system back pressure
is lessthan 0.75 inches of water column, the system is
acceptable. If the manometer reading is higher than .075
inches of water column, the system is too restrictive and
the installation is unacceptable.
Although vertical orientation of the exhaust system is
acceptable, certain extenuating circumstances could affect
the performance of the dryer:
• Only the rigid metal duct work should be used.
Venting vertically through a roof may expose the exhaust
system to down drafts causing an increase in vent
restriction.
Running the exhaust system through an uninsulated area
may cause condensation and faster accumulation of lint.
Compression or crimping of the exhaust system will cause
an increase in vent restriction.
The exhaust system should be inspected and cleaned a
minimum of every 18 months with normal usage. The
more the dryer is used, the more often you should check
the exhaust system and vent hood for proper operation.
Exhaust direction
Directional exhausting can be accomplished by installing a
quick-turn 90° dryer vent elbow directly to exhaust outlet of
dryer. Dryer vent elbows are available through your local parts
distributor or hardware store.
See also CLEARANCE REQUIREMENTSon the next page.
Use of 90° quick-turn elbow required to meet mini-
mum installation depth of free-standing dryer:
Straight back venting allows for 0" (0 cm) installation.
Venting right with 90° elbow allows for 0.75" (2 cm)
installation.
Venting downward with 90° elbow allows for 0.75" (2 cm)
installation.
Venting left with short, straight adapter and 90° elbow
allows for 3.75" (9.5 cm) installation.
Venting upward with short, straight adapter and 90°
elbow allows for 4" (10.5 cm) installation.
Manufactured or mobile home installation
1. Installation MUST conform to current Manufactured
Home Construction & Safety Standard, Title 24 CFR, Part
32-80 (formerly the Federal Standard for Mobile Home
Construction and Safety, Title 24, HUD Part 280) or
Standard CAN/CSAZ240 MH.
2. Dryer MUSTbe exhausted outside (outdoors, not beneath
the mobile home) using metal ducting that will not support
combustion. Metal ducting must be 4 inches (10.16 cm)in
diameter with no obstructions. Rigid metal duct ispreferred.
3. If dryer is exhausted through the floor and area beneath
the mobile home is enclosed, the exhaust system MUST
terminate outside the enclosure with the termination
securely fastened to the mobile home structure.
4. Refer to previous sections in this guide for other important
exhaust venting system requirements.
5. When installing a gas dryer into a mobile home, a
provision must be made for outside make up air. This
provision isto be not lessthan twice the area of the dryer
exhaust outlet.
6. Installer MUST anchor this (1) dryer or (2) dryer mounted
on pedestal to the floor with approved Mobile Home
Installation Kit- P/N 137067200.
Clearance requirements
- EXPLOSION HAZARD - Do not install the
dryer where gasoline or other flammables are kept or stored.
If the dryer is installed in a garage, it must be a minimum
of 18 inches (45.7 cm) above the floor. Failure to do so can
result in death, explosion, fire or burns.
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains,
drapes, or anything that will obstruct the flow of com-
bustion and ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of
1 inch (2.54 cm).
INSTALLATION IN A RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recessor closet,
MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the
same closet asthe gas dryer.
3. Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid door.
4. Closet door ventilation required: A minimum of 120
square inches (774.2 cm2)of opening, equally divided at
the top and bottom of the door, is required. Openings
should be located 3 inches (7.6 cm) from bottom and top
of door. Openings are required to be unobstructed when
a door is installed. A Iouvered door with equivalent air
openings for the full length of the door is acceptable.
MINIMUM INSTALLATIONCLEARANCES -Inches (cm)
SIDES REAR TOP FRONT
Alcove 0" (0 cm) 0" (0 cm)* 0" (0 cm) n/a
Under-
Counter
Closet 0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.5 cm)
* For other than straight back venting, a quick-turn 90°
dryer vent elbow (vented right or down in free-standing
dryer or right on pedestal-mounted dryer) must be
installed to achieve 0" (0 cm)installation.
0" (0 cm) 0" (0 cm)* 0" (0 cm) 1" (2.5 cm)
ii
ii
0" -----I1_ _---
(0cm) _ I
_L
0
! t
!
ii ii
ii H
1" --"!l_h _--" 0" _"'€_ m "_'-_
(2.54cm) i _ (Ocm) ii
closet door
i
To achieve an installation with 0" (0 cm) clearance
for the back of the dryer (for other than straight back vent-
ing), a quick-turn 90° dryer vent elbow must be installed as
described previously in this manual.
Installed dryer dimensions
._=== 48.25" (122.5cm)'
to clear open door
freestand dryer
on floor
.......... fLo_r=l_ = = =
30.5" (77,5cm)* _-
to front of dosed door
51,25"
(130cm)
36.0"
(91.5cm)
gas supply
pipe on rear
of gas unit
27.0"
(68.5cm)
0
electrical
supply on
rear of unit
c_'_enterline
height for
rear vent
dryer mounted on
optional pedestal
* To obtain these minimal depth dimensions, dryer must be vented straight back.
Using a quick-turn 90 ° elbow (right or down on freestanding dryer) adds approximately
0.75 in. (2.0 cm) to instanation depth. Upward venting of exhaust on pedestal-mounted
or freestanding dryer adds approximately 4 in. (10.2 cm) to installation depth. Leftward
venting on pedestal-mounted or freestanding dryer adds approximately 3.75 in. (9.5 cm)
to installation depth. Downward venting of exhaust on pedestal-mounted dryer adds
approximately 2.25 in. (5.7 cm) to installation depth.
_,_===48.25" (122.5cm)'
to clear open door
f 6.9"
(43cm)
3.75"_ _l====
(9.5cm) _==== 13.50"_
gas supply
pipe on
of gas unit
(34.5cm)
to center of rear vent
27,0'
(68.5cm)
0
19.0"
(48cm)
electrical
supply on
rear of unit
centerline
height for
rear vent
0
l
39"
(99cm)
* To obtain these minimal depth dimensions, dryer must be vented straight back. Using a quick-turn 90 ° elbow (right) adds approximately 0.75 in. (2 cm) to
installation depth. Upward venting of exhaust on stacked dryer adds approximately 4 in. (40.2 cm) to installation depth. Downward venting of exhaust on
stacked dryer adds approximately 2.25 in. (6.5 cm) to installation depth. Leftward venting of exhaust on stacked dryer adds approximately 3.75 in. (9.5 cm) to
installation depth.
Electrical installation
The following are specific requirements for proper and safe
electrical installation of your dryer. Failure to follow these
instructions can create electrical shock and/or a fire hazard.
- ELECTRICAL SHOCK HAZARD -
• This appliance MUST be properly grounded. Electrical
shock can result if the dryer is not properly grounded.
Follow the instructions in this manual for proper ground-
ing.
Do not use an extension cord with this dryer. Some ex-
tension cords are not designed to withstand the amounts
of electrical current this dryer utilizes and can melt, creat-
ing electrical shock and/or fire hazard. Locate the dryer
within reach of the receptacle for the length power cord
to be purchased, allowing some slack in the cord. Refer
to the pre-installation requirements in this manual for the
proper power cord to be purchased.
longer drying times than dryers operating on 240 volt power
supply.
Grounding requirements - Electric dryer (USA)
- ELECTRICAL SHOCK HAZARD - Improper
connection of the equipment grounding conductor can result
in a risk of electrical shock. Check with a licensed electrician
if you are in doubt as to whether the appliance is properly
grounded.
For a grounded, cord-connected dryer:
1. The dryer MUST be grounded. In the event of a
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance for
electrical current.
2. After you purchase and install a 3 wire or 4 wire power
supply cord having an equipment-grounding conductor
and a grounding plug that matches you wiring system,
3. DO NOT modify the plug you've installed on this
For a permanently connected dryer:
1. The dryer MUST be connected to a grounded metal,
- ELECTRICAL SHOCK HAZARD -
A U.L.-approved strain relief must be installed onto pow-
er cord. If the strain relief is not attached, the cord can be
pulled out of the dryer and can be cut by any movement
of the cord, resulting in electrical shock.
Do not use an aluminum wired receptacle with a copper
wired power cord and plug (or vice versa). A chemical
reaction occurs between copper and aluminum and can
cause electrical shorts. The proper wiring and receptacle
is a copper wired power cord with a copper wired recep-
tacle.
Dryers operating on 208 volt power supply will have
the plug MUST be plugged into an appropriate, copper
wired receptacle that is properly installed and grounded
in accordance with all local codes and ordinances. If in
doubt, call a licensed electrician.
appliance. If it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
permanent wiring system; or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead
on the appliance.
Grounding requirements - Electric dryer (Canada)
- ELECTRICAL SHOCK HAZARD - Improper
connection of the equipment grounding conductor can result
in a risk of electrical shock. Check with a licensed electrician
if you are in doubt as to whether the appliance is properly
grounded.
For a grounded, cord-connected dryer:
1. The dryer MUST be grounded. In the event of a
malfunction or breakdown, grounding will reduce the
risk of electrical shock by a path of least resistance for
electrical current.
2. Since your dryer is equipped with a power supply
cord having an equipment-grounding conductor and
a grounding plug, the plug must be plugged into an
appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances. If in
doubt, call a licensed electrician.
3. DO NOT modify the plug provided with this appliance. If
it will not fit the outlet, have a proper outlet installed by a
qualified electrician.
1.Thedryerisequippedwithathree-prong(grounding)plug
foryourprotectionagainstshockhazardandshouldbe
pluggeddirectlyintoaproperlygroundedthree-prong
receptacle.
2. Theplugmustbepluggedintoanappropriateoutletthat
isproperlyinstalledandgroundedinaccordancewithall
localcodesandordinances.Ifindoubt,callalicensed
electrician.
3. DONOTmodifytheplugprovidedwiththisappliance.If
itwillnotfit theoutlet,haveaproperoutletinstalledbya
qualifiedelectrician.
Gas connection
Grounding type
wall receptacle
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong,
Powercord with
3-prong grounded plug
,J
"X
/
1. Remove the shipping cap from gas pipe at the rear of the
dryer.
DO NOT connect the dryer to L.R gas service
without converting the gas valve. An L.R conversion kit must
be installed by a qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D. semi-rigid or approved
pipe from gas supply line to the 3/8 inch (0.96 cm) pipe
located on the back of the dryer. Use a 1/2 inch to 3/8
inch (1.27 cm to 0.96 cm) reducer for the connection.
Apply an approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe connections.
Manual GASFLOW
Shutoff Flare _ Flare
Valve Union Union
; 1 1
--los R Nipple Flexible Inlet Plpeon
Open Connector Back of Dryer
All connections must be wrench-tightened
The supply line must be equipped with an ap-
proved manual shutoff valve. This valve should be located in
the same room asthe dryer and should be in a location that
allows easeof opening and closing. Do not block accessto
the gas shutoff valve.
3. Open the shutoff valve in the gas supply line to allow gas
to flow through the pipe. Wait a few minutes for gas to
move through the gas line.
Shutoff Valve-
Open position
4. Check for gas system leaks with a manometer. If a
manometer is not available, test all connections by
brushing on a soapy water solution.
- EXPLOSION HAZARD - NEVERtest for gas
leaks with an open flame.
10
3-wire receptacle
(NEMA type 10-30R)
- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
,
Install a UL-approved strain relief according to the power
cord/strain relief manufacturer's instructions in the power
cord entry hole below the accesspanel. At this time, the
strain relief should be loosely in place.
4. Thread an UNPLUGGED,UL-approved, 30 amp. power
cord, NEMA 10-30 type SRDT,through the strain relief.
5. Attach the power cord neutral (center wire) conductor to
the SILVERcolored center terminal on the terminal block.
Tighten the screw securely.
6. Attach the remaining two power cord outer conductors
to the outer, BRASScolored terminals on the terminal
block. Tighten both screws securely.
_ _ Access cover
screw
Terminal
_S ____ block
_______f (BRASS terminal)
___ (BRASS terminal)
........... UL-approved
.................. _// strain relief here
___ Install
Line 2
Neutral
Internal ground
(GREENscrew)
Terminal screw
recovery slot
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
7. Follow manufacturer's guidelines for firmly securing the
strain relief and power cord.
8. Reinstall the terminal block cover.
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal ground from
the center terminal back to the GREENscrew next to the
terminal block.
If a terminal screw falls during cord installation, it
can be retrieved in the terminal screw recovery slot below the
access panel.
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
11
Electrical connection (non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
- ELECTRICAL SHOCK HAZARD - Failure
to disconnect power source before servicing could result in
personal injury or even death.
-- Neutral
',WHITEwire)
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block access
cover in the lower corner on the back of the dryer.
3. Install a UL-approved strain relief according to the power
cord/strain relief manufacturer's instructions in the power
cord entry hole below the accesspanel. At this time, the
strain relief should be loosely in place.
4. Thread an UNPLUGGED,UL-approved, 30 amp. power
cord, NEMA 14-30 type ST or SRDT,through the strain
relief.
5. Disconnect the internal (BLACK) dryer harness ground
wire from the (GREEN)ground screw next to the terminal
block.
6. Attach the ground (GREEN)power cord wire to the
cabinet with the ground (GREEN)screw. Tighten the
screw securely.
7. Move the internal dryer harness ground (BLACK) wire to
the terminal block and attach it along with the neutral
(WHITE) power cord wire conductor to the center, SILVER
colored terminal on the terminal block. Tighten the screw
securely.
8. Attach the REDand BLACK power cord conductors to
the outer, BRASScolored terminals on the terminal block.
Tighten both screws securely.
- ELECTRICAL SHOCK HAZARD - Do not
make a sharp bend or crimp wiring/conductor at connections.
9. Follow manufacturer's guidelines for firmly securing the
strain relief and power cord.
10. Reinstall the terminal block cover.
Access cover
screw
block
Line 2
(BRASSterminal)
Neutral
(SILVERterminal)
Line 1
(BRASSterminal)
Internal ground
(GREENscrew)
............ UL-approved
____ Install
strain relief here
Terminal screw
recovery slot
If a terminal screw falls during cord installation, it
can be retrieved in the terminal screw recovery slot below the
access panel.
Move internal ground (BLACK)
neutral (SILVER)
wire to for 4-wire system. "_h
terminal
/
"\\\
GREEN
|
Neutral
terminal
WHITE
neutral wire
ground screw
12
GREEN
ground wir,
RED power wir
BLACK
or RED
power wire
BLACK or
General installation
.
Connect the exhaust duct to the outside exhaust system
(see pages 4 through 6). Use of a 4" (10.2 cm) clamp (item
A) isrecommended to connect the dryer to the exhaust
vent system. Use metal foil tape to seal all other joints.
.
Carefully slide the dryer to its final position. Adjust one or
more of the legs until the dryer is resting solidly on all four
legs. Place a level on top of the dryer. The dryer MUST be
level and resting solidly on all four legs. Rock alternating
corners to check for stability. Remove and discard door
tape.
Be sure the power isoff at a circuit breaker/
fuse box before plugging the power cord into an outlet.
3. Plug the power cord into a grounded outlet.
4. Turn on the power at the circuit breaker/fuse box.
5. Readthe Use& Care Guide provided with the dryer. It
contains valuable and helpful information that will save
you time and money.
6. If you have any questions during initial operation, please
review the "Avoid Service Checklist" in your Use & Care
Guide before calling for service.
7. Placethese instructions in a location near the dryer for
future reference.
A wiring diagram and technical data sheet are
located inside the dryer console,
wall rece
any circumstances,
Power coid with
3-prong grounded p!ug
13
Window Door Reversal Instructions
Figure I
1.Open door and remove four (4) plugs in the door opening
opposite the hinges. Retain all parts for uses later, unless
otherwise noted. (Figure I) Note: Use care in removing plugs
in not scratching paint on the front panel.
Figure 4
5, Remove two (2) door handle screws and two (2) hole plugs
from door. Again taking care not to scratch paint on door,
(Figure 4)
Figure 2
2, Begin removing the four (4) screws that attach the hinge to
the front panel. (Figure 2) For best results, start by only
removing one screw per hinge. Then only loosen the two
remaining screws while firmly holding door to prevent damage
to hinge, front panel or door. After the remaining screws are
loosened, continue to remove all.
Figure 3
3. Place door on a towel or pad handle side down to prevent
any possible scratches to door. Remove all remaining four (4)
screws between hinge and door. (Figure 3)
Figure 5
6. Pull handle away from door assembley, (Figure 5)
Figure 6
7. Separate the outer door from the inner door assembly with
a putty knife or flat screw driver, (Figure 6)
4. Remove four (4) screws from side of door opposite of where
hinge was mounted,
14
Figure 7
8. Remove lens locating screw. (Figure 7)
11.Reassemblelenstotransitionringwithholesto install
handleonright-handsideofdoorassembly.Forproperfit
insuretheretentiontabsontransitionringareontopoflens
Figure 11
12. Reassembly outer door to inner door assembly. (Figure 11)
13. Install four (4) screws securing hinge to door assembly in
the new location, take note to place hinge in correct
orientation.
14. Install four (4) screws into holes that had secured the
hinge.
15. Remove striker and discard.
Figure 8
9. Disengaging several of the retention tabs and pull lens away
from the transition ring. (Figure 8)
Figure 9
16. Remove square plug and reinstall in hole striker was just
removed.
17. Install striker (included in literature bag) into hole square
plug was previously installed.
Figure 12
18. Reinstall door handle by placing the handle mounting
bossesthrough holes in lens and transition ring and installing
screws through inner door and tighten into handle bosses.
(Figure 12).
Figure 10
10. Remove two (2) transition ring plugs and reinstall on
previous handle side. (Figures 9 and 1O)
19. Grasping firmly the top of the door, position the door near
the door opening and align the top hinge hole to the top hole
in the front panel door opening. Once the first screw is started,
attach the second screw to the lower hinge. Once both screws
are tightened, instal{ the remaining two screws.
20. Install four (4) plugs into the front panel door opening
where hinges were originally installed.
15