|nstallation instructions
READ BEFORE iNSTALLiNG UNiT
Compact Window Mounting
Your air conditioner is designed to install in standard 
double hung windows with opening widths of 23 to 36
inches (584 mm to 914 ram) (FIG. l) 
Lower sash must open sufficiently to allow aclear vertical
opening of 14-1/2 inches (368 mm). Side louvers and the 
rear of the AC must have clear air space to allow
enough airflow through the condenser, for heat removal. 
The rear of the unit must be outdoors, not inside a
building or garage.
Fig. 1
EXTERIOR
When handling unit, be careful to avoid cuts 
from sharp metal edges and aluminum fins on
front and rear coils.
Before installing unit, the top rail must be 
assembled on the unit.
Top Rail Hardware Qty.
3/8" Screw 4
Top Rail l
NOTE: SAVE CARTON and these INSTALLATION
INSTRUCTIONS for future reference. The carton is the
best way to store unit during winter, or when not in use.
Some assembly is required. Please read these instructions
carefully.
,f
Mounting Hardware
3/4" screws
lock flame
sash lock
TOOL NEEDED: 
, Phillips Screwdriver
A. Remove the air
conditioner from the 
carton and place on a
fiat surface. Packaging
B. Remove top rail from
the rear of the 
packaging material as
shown in Fig. A
C°
Align the hole in the
top rail with those in 
the top of the unit as
shown in Fig. B
D,
Secure the top rail to
the unit with the 3/8"
Screws as shown in
Fig. C
Top 
Rail
TOOLS NEEDED:
• PhillipsScrewDriver 
, Drill(Ifpilotholesareneeded)
NOTE: DO NOT USE ANY SCREWS OTHER THAN 
THOSE SPECIFIED HERE
NOTE: FOR SAFETY REASONS, ALL 
FOUR (4) SCREWS MUST BE SECURELY
FASTENED.
P/N 2020215A0201

How to Install
NOTE: "Fop Rail and Sliding Panels at each side are
offset to provide the proper pitch to the rear of (5/16"). 
This is necessary for proper condensed water utilization 
and drainage. If you are not using the Side Panels for 
any reason, this pitch to the rear must be maintained!
Place unit on floor, a bench or a table. There is a 
Left and Right Window Filler Panel - be sure to
use the proper panel for each side.When installed 
the flange for securing the panel in place to the window sill 
will be facing into the room.
A. Hold the
Accordion 
Panel in one
hand and 
gently pull
back the 
center to free
the open end.
See Figure 2.
Co
Once the panel 
has been
installed on the 
side of the
cabinet, make 
sure it sits
securely inside 
the frame
channel by 
making slight
adjustments. Slide the top and bottom ends of the frame 
into the top and bottom rails of the cabinet. Figure 5.
D. Slide the panel all the way in and repeat on the other
side.
B. Slide the free end (" I "section) of the pane! into
the cabinet as shown in Figures 3A, 3B & 4. Slide the 
panel down. Be sure to leave enough space to slip the
top and bottom of the frame into the rails on the cabinet.
NOTE: If stormwindowblocksAC,seeFIG. 14.
Keep a firm grip on the air conditioner, carefully 
place the unit into the window opening so the
bottom of the air conditioner frame is against the 
window sill (FIG. 6 & FIG. 6A). Carefully close the 
window behind the top rail of the unit.
WINDOW SILL
Extend the side panels out against the window 
frame (FIG. 7).
2

Place the frame lock between the frame 
extensions and the window sill as shown
(Fig. 8). Drive 3/4" (19 ram) locking
screws through the frame lock and into the sill 
(FIG. 9). NOTE: To prevent window sill from 
splitting, drill 1/8" (3 ram) pilot holes before
driving screws.
Drive 1/2" (13 ram) locking screws 
through frame holes into window sash
(FIG.10/11).
Cut foam seal and insert in the space 
between the upper and lower sashes
(riG.13).
IfAC is Blocked by Storm
Window
Add wood as shown in FIG. 14, or remove storm 
window before air conditioner is installed.
FiG. 14
SASH
STORM WINDOW 
FRAME
OR OTHER 1 1/2" MIN 
OBSTRUCTION (38 ram) .
BOARD 
THICKNESS 
AS REQUIRED,
FOR PROPER 
PITCHTO 
REAR,ALONG 
ENTIRESILL.
FASTENWITH 
NAILS OR 
SCREWS.
To secure lower sash in place, attach right 
angle sash lock with 3/4" (19 ram) screw 
as shown (FIG. 12).
If Storm Window Frame must remain, be sure the 
drain holes or slots are not caulked or painted
shut. Accumulated Rain Water or Condensation 
must be allowed to drain out.
Removing AC From
Window
* Turn AC off, and disconnect power cord. 
* Remove sash seal from between windows,
and unscrew sash lock.
* Remove screws installed through frame and
frame lock.
* Close (slide) side panels into frame. 
* Keeping a firm grip on air conditioner, raise
sash and carefully "rock" air conditioner 
backward to drain any condensate water in
base of unit. Be careful not to spill any 
remaining water while lifting unit from
window. Store parts WITH air conditioner.