AIRCONDITIONER
For questions about features, operation/performance, par[s,
accessories or service call: 1-800-253-1301
Table of Contents ................................................ 2
1188226
TABLEOF CONTENTS
AIR CONDITIONER SAFETY ......................................................... 2
INSTALLATION REQUIREMENTS ................................................ 3
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 3
Electrical Requirements ............................................................... 4
INSTALLATION INSTRUCTIONS .................................................. 5
Unpack the Air Conditioner .......................................................... 5
Window Installation ...................................................................... 6
SMART-MOUNT TM Tray Assembly ................................................ 6
Prepare Air Conditioner for Window Installation ......................... 8
Position the Air Conditioner in Window ....................................... 9
Complete Installation ................................................................. 10
Through-the-Wall Installation ..................................................... 11
SMART-MOUNT TM Tray Assembly .............................................. 12
Position the Air Conditioner Through the Wall ............................
Complete Installation.................................................................. 16
AIR CONDITIONER USE .............................................................. 16
Starting Your Air Conditioner--Digital Control .......................... 16
Starting Your Air Conditioner-- Rotary Control .......................... 19
Changing Air Direction ............................................................... 20
Normal Sounds ........................................................................... 20
AIR CONDITIONER CARE ........................................................... 21
Cleaning the Air Filter ................................................................. 21
Cleaning the Front Panel ............................................................ 21
Repairing Paint Damage ............................................................ 21
Annual Maintenance ................................................................... 21
TROUBLESHOOTING .................................................................. 22
ASSISTANCE OR SERVICE ......................................................... 23
In the U.S.A................................................................................ 23
Accessories ................................................................................ 23
AIRCONDITIONERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all
safety messages.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or
This is the safety alert symbol.
"WARNING." These words mean:
You can be killed or seriously injured if you don't
immediately follow instructions.
You can be killed or seriously injured if you don't
follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you
what can happen if the instructions are not followed.
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: To reduce the risk of fire, electrical shock or injury when using your air conditioner, follow these basic precautions:
[] P(ug into a grounded 3 prong outlet. [] Do not use an extension cord.
[] Do not remove ground prong. [] Unp(ug air conditioner before servicing.
[] Do not use an adapter. [] Use two or more people to move and install air conditioner.
SAVE THESE iNSTRUCTiONS
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
• Flat-blade and Phillips
screwdrivers
• 1/4"nut driver
• 7/16" wrench
• Scissors
Through-the-Wall Installation
In addition to the tools listed above, the following tools are
needed for through-the-wall installation.
• Saw • Caulk
• Wood preservative • 1" (2.5 cm) or thicker
• Pencil
• Tape measure
• Level
• Drill
• %2" or smaller drill bit
lumber
Parts supplied
Check that all parts are included in parts package.
Air conditioner installation
G
IMPORTANT: Observe all governing codes and ordinances.
Check the location where the air conditioner will be installed.
Proper installation is your responsibility. Make sure you have
everything necessary for correct installation.
The location should provide:
• Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
• Free movement of air in room to be cooled.
• A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
• Adequate wall support for weight of air conditioner. Air
conditioner weighs 80 Ibs (36.3 kg) to 125 Ibs (56.7 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
A_
A. Window-lock bracket
B. #8 x _" pan-head screws (6)
C. #8 x ¾" round-head screws (3)
D. #10 x _" pan-head screws (3)
SMART-MOUNT" tray assembly installation
D
E F G H I J
E.Side curtains (2)
F. Top channel
G. Foam seal
H. Side curtain frames (2)
H
Window Installation
Window opening measurements:
• 27" (68.6 cm) minimum to 40" (101.6 cm) maximum opening
width.
• 19" (48.3 cm) minimum opening height.
A. Cabinet louvers
At_
B
( (_
LL r
A.27" (68.6cm) minimum, 40" (101.6 cm)maximum
B. 19" (48.3cm) minimum
A. Tray back
B. Tray center
C. Tray sides (2)
D. Support legs (2)
E.#8- 18x _"hex- H. Hexnuts(4)
head screws (4) L Carriage bolts (4)
F. Flatwashers(4) J.#10-12x1½"slot-
G. Lock washers (4) head wood screws (2)
Through-the-Wall Installation
The wall opening measurements should be:
• Height: 18" (45.7 cm) plus twice the thickness of wood used
to build frame.
• Width: 26" (66 cm) plus twice the thickness of wood used to
build frame.
• Depth: 2" (5 cm) minimum to 8" (20.3 cm) maximum.
t
C
A. 18" (45.7 cm) C. Wood thickness
B. 26" (66 cm) D. 2" (5 cm) minimum to 8" (20.3 cm) maximum
E_ectricaJ Shock Hazard
Plug into a grounded 3 prong outJet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord Wiring requirements
• 115 volt (103.5 min. -
126.5 max.)
• 0-12 amps
• 15-amp time-delay fuse or
circuit breaker
• Use on single outlet circuit
only.
• 230 volt (207 min. -
IA,, 253 max.)
(0.6 cm)
• 15-amp time-delay fuse or
_ • 0-12 amps
Recommended ground method
For your personal safety, this air conditioner must be grounded.
This air conditioner is equipped with a power supply cord having
a grounded 3 prong plug. To minimize possible shock hazard, the
cord must be plugged into a mating, grounded 3 prong outlet,
grounded in accordance with all local codes and ordinances. If a
mating outlet is not available, it is the customer's responsibility to
have a properly grounded 3 prong outlet installed by a qualified
electrical installer.
It is the customer's responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.
Copies of the standards listed may be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
circuit breaker
• Use on single outlet circuit
only.
Power Supply Cord
NOTE: Your unit's device may differ from the one shown.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
B
A. Reset button
B. Test button
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of a second.
ElectricaJShockHazard
Pluginto a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or eJectrical shock.
To test your power supply cord:
1. Plug power supply cord into a grounded 3 prong outlet,
INSTALLATIONINSTRUCTIONS
2. Press RESET.
3. Press TEST (listen for click; Reset button will trip and pop
out).
4. Press and release RESET (listen for click; Reset button will
latch and remain in). The power supply cord is ready for
operation.
NOTES:
• The Reset button must be pushed infor proper operation.
• The power supply cord must be replaced if it fails to trip when
the test button is pressed or fails to reset.
• Do not use the power supply cord as an off/on switch. The
power supply cord is designed as a protective device.
• A damaged power supply cord must be replaced with a new
power supply cord obtained from the product manufacturer
and must not be repaired.
• The power supply cord contains no user serviceable parts.
Opening the tamper-resistant case voids all warranty and
performance claims.
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
Remove packaging materials
• Remove and properly dispose of packaging materials.
Remove tape and glue residue from surfaces before turning
on the air conditioner. Rub a small amount of liquid dish soap
over the adhesive with your fingers. Wipe with warm water
and dry.
• Do not use sharp instruments, rubbing alcohol, flammable
fluids, or abrasive cleaners to remove tape or glue. These
products can damage the surface of your air conditioner.
• Handle air conditioner with care.
1. Locate provided bag of pan-head screws.
2. Place the top channel on top of the air conditioner, lining up
the holes in top channel with the holes on top of air
conditioner.
3. Using 3 - #10 x %" pan-head screws, attach top channel to
air conditioner.
B A B
A. Topchannel
B.#10 x _" pan-head screw
i
3
Using the tray back as a template, center in windowsill
against outside edge of stool.
C
A. Tray back
B. Windowsill
C. Outside edge of stool
2.
Using the 2 inside screw holes in tray back, mark
screw locations on windowsill for mounting the
SMART-MOUNT TM tray.
1. To assemble the tray frame, insert tab on tray back into slot
on tray side. Check to see that the tab is engaged and the
2 pieces are aligned. Insert 2 - #8 - 18 x 1/4"hex-head screws
to secure.
2. Repeat with other tray side.
3.
Remove tray back. Using these marks, drill %2" pilot holes in
the windowsill approximately 11/2"(3.8 cm) deep.
C
A
A. Tray back
B. #8 - 18 x _" hex-head screws
C. Tray side
Attach support legs
1. Determine the correct slots on the tray side from the type of
exterior construction of the building.
Thin wall construction (vinyl, wood, etc.)
A
3. Place one end of tray center over carriage bolt.
A.First and second slots
Thick wall construction (brick}
A
A. Second and third slots
2,
Insert carriage bolt up through slot on tray-frame side and
support leg.
4. Then place flat washer, lock washer and hex nut.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
...........A
.......i%11........
A. Hex nut D. Tray center
B. Lock washer E.Carriage bolt
C. Flat washer
5,
Insert second carriage bolt through tray side and attach other
end of support leg.
NOTE: Do not tighten. The leg must be able to move freely to
adjust angle when installed.
,, c
A.Hox nut C.Flatwasher
B.Lock washer D.Carriagebolt
6,
Install support leg on other side.
D
Install SMART-MOUNT '_Tray Assembly in window
1. From inside, place SMART-MOUNT TM tray, support legs facing
down, in the window. Match the holes in tray side with the
predrilled holes in windowsill.
2. Using 2 - #10 - 12 x 11/2"slot-head wood screws, secure the
tray frame to the window.
A. #10 - 12x 1_" slot-head wood screws
NOTE: If the exterior of building can be damaged by support
legs, place a board between the wall and support legs.
3. With tray center pushed away from the windowsill, place a
level on the angled edge of tray side. Be sure level is against
notch on tray side. Adjust SMART-MOUNT TM tray until bubble
indicates the tray is level.
Install side curtains
NOTE: Attach curtains to unit before placing unit in window.
1. Insert curtain into curtain frame. Make sure curtain end locks
into curtain frame.
A. Place level on angled edge against notch on tray side.
4. Tighten the hex nut just enough to hold tray center in place.
5. Repeat with other side.
6. Tighten hex nuts securely with 7_6"wrench.
2. Push curtain in all the way.
3. Pull curtain toward open end of curtain frame.
4=
Insert top and then bottom of right-hand curtain frame in top
and bottom curtain guides on air conditioner.