Crompton Instruments Saxon Indicators Data Sheet

Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002
Analogue Instruments
Saxon Indicators
Features
Three case sizes IP54 (NEMA 3) protection Withstands high levels of
Complies with: ANSI C39.1 (IEC 51)
UL Approved (File No. E203000)
Instruments comply with BSEN61010-1 and meet IEC414 (BS5458) Dielectric Test (2600V for 1min)
Taut Band Mechanisms as standard
The Saxon range offers 2
1
/
2
",
3
1
/
2
" and 4
1
/
2
" surface mount panel meters designed to perform in demanding environmental applications sealed to IP54, NEMA 3, UL52 type 12/13.
Elapsed Time Meter and Frequency Meter
Accuracy: 0.15 = 60Hz
1.25 = 400Hz
0.15 = 50Hz
0.25 = 55Hz
Voltage: 110/130V
200/250V
Frequency: 50Hz or 60Hz Burden: 4VA Maximum
Dimensions
Specify number of fixing studs when ordering
Iron Vane A.C. Ammeter & Voltmeter
Accuracy: ±2% Rating:
Ammeters: 1 to 30A Voltmeters: 10V to 600V
Overload:
Ammeters: x1.2 for 2 hours
x10 for 5 seconds
Voltmeters: x1.2 for 2 hours
x2 for 5 seconds
Burden:
Ammeters: 0.5VA Voltmeters: 4.5VA maximum
Moving Coil D.C. Ammeter & Voltmeter
Accuracy: ±2% Rating:
Ammeters: 100µA to 30A Voltmeters: 50mV - 600V
Operating Temp: -20°C to 60°C Storage Temp: -30°C to 70°C
ABCDEFGHJKLMNPQ
2 1⁄2 mm 68.6 68.6 11.8 14.6 32.0 25.4 10.4 12.7 55.9 31 46.5 26.9 23.9 47.8 23.9
inch 2.70 2.70 0.46 0.57 1.26 1.00 0.41 0.50 2.20 1.22 1.83 1.06 0.94 1.88 0.94
3 1⁄2 mm 88.9 88.9 11.8 14.6 36.0 25.4 10.4 12.7 69.9 40.2 60.3 34.8 28.5 57.0 28.5
inch 3.5 3.5 0.46 0.57 1.42 1.00 0.41 0.50 2.75 1.58 2.37 1.37 1.12 2.24 1.12
4 1⁄2 mm 112.0 123.2 12.7 16.3 30.5 28.4 0.38 12.7 70.9 51.6 90.4 50.8
inch 4.41 4.85 0.50 0.64 1.20 1.12 0.41 0.50 2.78 2.03 3.56 2.00
Panel cut-out
Web: www.crompton-instruments.com • Email: crompton.info@tycoelectronics.com 2002
Analogue Instruments
Saxon Indicators
Rating Scaling Catalogue No.
A.C. Ammeter True RMS Reading - Accuracy ±2% ES
5A 0-5a (01*)-75AA-lsls-C6-B* 10A 0-10a (01*)-75AA-mtmt-C6-B* 15A 0-15a (01*)-75AA-ndnd-C6-B* 20A 0-20a (01*)-75AA-ngng-C6-B* 30A 0-30a (01*)-75AA-nlnl-C6-B* 1A Transformer Rated (01*)-75AA-LA**-C6-B* 5A Transformer Rated (01*)-75AA-LS**-C6-B*
A.C. Voltmeter True RMS Reading - Accuracy ±2% ES
150v 0-150V (01*)-75VA-PZPZ-C6-B* 300v 0-300V (01*)-75VA-RXRX-C6-B* 600v 0-600V (01*)-75VA-SJSJ-C6-B* 150V transformer Rated (01*)-75VA-PZ**-C6-B*
D.C. Ammeters - Accuracy ±2% ES
0-1mA To Suit Requirements (01*)-01AA-FA**-B* 0-5mA 0-5mA (01*)-01AA-FXFX-B* 0-10mA 0-10mA (01*)-01AA-GZGZ-B* 0-20mA 0-20mA (01*)-01AA-HFHF-B* 0-50mA 0-50mA (01*)-01AA-HYHY-B* 0-100mA 0-100mA (01*)-01AA-JRJR-B* 0-200mA 0-200mA (01*)-01AA-KAKA-B* 0-500mA 0-500mA (01*)-01AA-KMKM-B* 0-600mA 0-600mA (01*)-01AA-KPKP-B* 0-1A 0-1A (01*)-01AA-LALA-B* 0-2A 0-2A (01*)-01AA-LELE-B* 0-4A 0-4A (01*)-01AA-LLLL-B* 0-5A 0-5A (01*)-01AA-LSLS-B* 0-6A 0-6A (01*)-01AA-LWLW-B* 0-10A 0-10A (01*)-01AA-MTMT-B* 0-50mV To Suit (01*)-01AA-EC**-B* 0-100mV To Suit (01*)-01AA-GB**-B*
Milliammeters Suppressed Zero - Accuracy ±2% ES
4-20mA To Suit Requirements (01*)-01RA-HG**-B*
**Specify scale value
D.C. Voltmeters Sensitivity 1000/Volt - Accuracy ±2% ES
0-15V 0-15V (01*)-01VA-NDND-B* 0-30V 0-30V (01*)-01VA-NLNL-B* 0-50V 0-50V (01*)-01VA-NTNT-B* 0-150V 0-150V (01*)-01VA-PZPZ-B* 0-300V 0-300V (01*)-01VA-RXRX-B* 0-600V 0-600V (01*)-01VA-SJSJ-B*
Frequency Meters 120V - Self Contained
50Hz 45-55Hz (01*)-41SA-PNAG-AG-B* 55Hz 45-65Hz (01*)-41SA-PNAJ-AJ-B* 60Hz 55-65Hz (01*)-41SA-PNAN-AN-B*
Elapsed Time Meters 99999.99 hours - non reset
110/130V, 50Hz - (01*)-155A-PNZH-C5-B* 200/250V, 50Hz - (01*)-155A-RNZH-C5-B* 480V, 50Hz - (01*)-155A-SEZH-C5-B* 110/130V, 60Hz - (01*)-156A-PNZH-C6-B* 200/250V, 60Hz - (01*)-156A-RNZH-C6-B* 480V, 60Hz - (01*)-156A-SEZH-C6-B*
A.C. Ammeter
A.C. Voltmeter
Frequency Meter
To denote the required case size, replace the 01* in the catalogue number with 012, 013 or 014 for 2
1
/
2", 3
1
/
2" or 4
1
/
2" respectively.
To denote the required stud fixing configuration, replace B* with B2 (2 stud), B3 (3 stud) or B4 (4 stud)
For an alternate voltage rating of 200-250V use code RN instead of PN
For an alternate voltage rating of 380-480V use code SE instead of PN