CRMET CH2165, CH2160, CH2124 Datasheet

HIGH SPEED INTERNET MODEM FAMILY
CH2124 - Send/Retrieve Email. 2 I/O Ports 2400bps. CH2160 - Send/Retrieve Email. 2 I/O Ports, V.90.
CH2165 - Send/Retrieve Email. Unlimited Email, V.90
2003 Cermetek Microelectronics, Inc. Page 1 Document No. 607-0017 Revision H2 (11/03)
Replaces conventional modems using the world wide web for communication.
Transparent internet operations of Point-to-Point Protocol (PPP), Password Authentication Protocol (PAP) and Challenge Authentication Protocol (CHAP) to connect to the Internet.
Built-in TCP/IP and SMTP to send emails, TCP/IP and POP3 to retrieve and/or delete emails.
On Demand and I/O pin event driven email transmission and retrieval.
Send/Retrieve streaming email of unlimited length; or pre-stored email up to 5M bytes in RAM (CH2165).
Retrieve multiple messages (CH2165) or select individual message (CH2124/60).
Once online CH2165 can stay online and send, retrieve and/or delete email.
Programmable using serial interface (CH2124/60/65).
Remote programming using PSTN (CH2124/60).
Resident modem supports: V.90, V.34bis, V.34,
V.22bis, V.22A/B V.23, V.21, Bell 212A and 103, (depending on model) and can be used in conventional modem mode.
Error correcting: V.42 LAPM, MNP 2-4 and MNP10.
Automatic baud rate adaptability utilizing speed
sensing, flow control and data buffers.
Serial interface, V.24 (EIA 232-E), 5 volts.
NVRAM for stored modem (S-Registers) profiles.
Cermetek @T
®
AT-like Commands.
Built-in DAA with 1500 VAC RMS isolation 2122V peak surge protection.
UL 1950 and CSA C22.2 950 (Third Edition) Listed, reference UL File E104957.
FCC Part 68 Approved/DOT CSA CS-03 Part I approvable.
Pin-for-Pin compatible family.
+5 Volt operation.
Small size: 1.35” x 1.97” x 0.55” (nominal).
Low Cost 2400bps version (CH2124).
Use with any Non-proprietary commercial or private
ISP.
Cermetek’s iModem Network ISP has 1000s of local access numbers world wide.
Failsafe back up 1-800 access number, auxiliary
and alternative telephone numbers available.
Low cost iModem Network ISP providing email to Voice, Fax, and email re-routing services.
90 day free trial subscription to iModem Network ISP provided with each iModem.
INTRODUCTION
Direct machine-to-machine interaction represents the next logical extension of the internet. Cermetek internet modem (iModem) products are designed to exploit the internet to facilitate the utilization of machine-to­machine interactions. Using email, information can easily be transferred between systems and can be transmitted/retrieved at will. Internet email provides low cost, near real time multi-path communication. Replacing conventional modems and long distance telephone lines with local access internet connections reduces fixed asset and maintenance costs, limits communication expenses and saves money.
USER FRIENDLY INTERFACE LAYER
All Cermetek iModem products contain a user friendly interface layer that provides the user transparent access to the internet. This interface layer, consisting of various @T
®
macro commands, has the look and feel
of conventional modem AT commands. With the @T
®
macro commands the user can direct the iModem to compose, edit/modify, send, retrieve and delete email messages. Internet and email activity status is reported via the iModem’s V.24 (EIA 232-E) serial interface.
COMPARISON OF CH21XX iMODEM DEVICES
The CH2165 represents the next generation in internet enabled devices. This product provides the user with unsurpassed command and control capabilities. The CH2165 communicates asynchronously with the host controller (via the serial port) and the internet (via the PSTN connection) simultaneously. Consequently, the user can intersperse CH2165 specific management commands with internet commands. Further, commands can be queued. The CH2165 will also send or retrieve email messages of virtually unlimited length by using streaming email techniques. The CH2165 is ideal for applications where larger data transfers are required and/or where large amounts of data must be stored locally on the iModem device.
Cermetek Microelectronics, Inc. High Speed Internet Modem Family
2003 Cermetek Microelectronics, Inc. Page 2 Document No. 607-0017 Revision H2 (11/03)
Figure 1. Conceptualized Block Diagram illustrating the Cermetek CH21XX iModem product family performing the embedded internet application function.
The CH2124/60 products are the first generation internet enabled devices. These products excel at sending and retrieving modest amounts of data. Email messages of approximately 125 ASCII characters in length can be stored in internal Flash ROM for later transmission.
The CH2124/60 products are ideal for very low cost controller applications and in applications where limited data transfer is required.
OVERVIEW OF THE CH21XX iMODEM
A conceptual representation of the iModem in an embedded environment is presented in Figure 1. As can be seen in this figure, the iModem requires the input of various internet parameters to function properly: user name, user ID, user password, ISP telephone number, ISP mail server address/name, local email address/name, destination email address and user specified email message/input port status.
Cermetek’s iModem products provide the user with the ability to assign a unique unit name to each iModem thereby creating a customized identity for each system containing an iModem product.
Each iModem device stores the user-supplied parameters in internal memory. These parameters are retained when power is removed. The user supplied parameters are loaded into the iModem via the iModem’s serial interface port utilizing either Cermetek’s iNetWizard
®
telecommunications software
package or, alternatively, one of a variety of commercially available terminal emulation software
packages. iNetWizard
®
is available free of charge and
runs on any standard PC operating Microsoft Windows.
Internet Connectivity. The CH21XX iModem uses the user supplied parameters to establish an internet connection and then send, retrieve and/or delete email. After completion of the required internet activities, the iModem terminates the internet connection.
Send, Retrieve and Delete Email: CH2165. The CH2165 has the ability to send and retrieve emails of virtually unlimited length by employing a technique referred to as streaming email. Once in streaming email mode, the user simply continues to supply data to the CH2165’s serial port, and terminates the data stream with a <CR>.<CR>. Alternatively, messages of finite length can pre-stored locally on the CH2165 in RAM memory and then sent when needed. The data stream termination sequence for pre-stored messages is the CTRL D characters.
The total CH2165 RAM memory available to the user is approximately 5M bytes. For messages that need to be stored semi-permanently, the user has access of up to 1M byte of Flash ROM for message storage. Messages stored in ROM can also be sent when needed.
When retrieving emails, the user continues to save the data streaming out of the CH2165’s serial port until a <CR>.<CR> is received.
Refer to Cermetek Application Note # 325, @T
®
Command Set Description and Usage For CH2165 iModem, for more details.
User Name
Password
ISP Telephone Number
Mail Server Address/Name
Local Email Address
Destination Email Address
User Specified Email
Message/Input Port Status
User ID
User Supplied Parameters
Send email
Retrieve email
Delete email
CH21XX iModem Product
Family
Internet
(PPP, SMTP, TCP/IP,
POP3)
Cermetek Microelectronics, Inc. High Speed Internet Modem Family
2003 Cermetek Microelectronics, Inc. Page 3 Document No. 607-0017 Revision H2 (11/03)
Send, Retrieve and Delete Email: CH2124/60. The CH2124/60 products send and retrieve email of modest length. The pre-stored message length is approximately 125 ASCII characters. Messages are stored in Flash ROM. Streaming email is not supported in the CH2124/60 iModem products.
Refer to Cermetek Application Note # 155, @T
®
Command Set Description and Usage For CH2124/60 iModems, for more details.
iModem Hardware Configuration. Each CH2160/65 (CH2124) iModem contains a fully functional 56kbps (2400bps) modem and the hardware and firmware needed to provide the internet capability. Because of the unique architecture of Cermetek iModems, these iModems have the ability to operate as either an internet email transceiver or as a high reliability analog modem. Additionally, the CH2124/60 products support user remote access which can be used to reprogram or reconfigure an iModem deployed in the field.
The iModem Family of products are pin compatible with the CH179X and CH2056 modem products. Referring to Figure 2, the CH21XX iModem Family consists of an industrial grade high speed modem module and a µP controller with associated internal logic. The µP controller and the logic provide all the functions required for internet communication via standard PSTN telephones lines. The CH2165 contains an additional 8 Mbytes of RAM and 2 Mbytes of Flash ROM. All CH21XX iModem products utilize TCP/IP, PPP, PAP, CHAP, SMTP and POP3 internet protocols.
Required External Connections. The iModem requires an external RJ-11C jack for the PSTN line connection. An CCITT V.24 serial interface is required when host processor control of the iModem is required in the specific application. All retrieved emails are presented to the host system for further processing and/or retention via the serial interface.
Approvals. The CH21XX iModem Family is FCC Part 68 approved, UL 1950 and CSA C22.2 950 (Third Edition) listed and Canadian DOT CSA CS-03 approvable.
Physical Dimensions. The modules are designed for PCB through-hole mounting and are 1.35” x 1.97” x
0.55” in size.
iMODEM EVALUATION BOARD
Cermetek manufactures a companion evaluation board that is designed to simplify the hardware connections required to program the iModem as well as providing a reliable platform to assist with system level debugging. Contact Cermetek and ask for the CH21XX iModem Evaluation Board.
iMODEM NETWORK ISP
A valid ISP account ID and password are required to access the internet. As a convenience to our customers, and to facilitate operational use of the iModem, Cermetek supplies each iModem with a pre­programmed account on the Cermetek iModem Network ISP. This account is provided on a 90 day free trial offer basis. Cermetek established the iModem Network ISP to provide embedded internet appliance users with features and services tuned to the unique demands of the internet appliance environment. In addition to standard email service, the iModem Network ISP can provide: email to FAX, email to Voice, email to dynamic web page update, and email re­routing. Refer to Cermetek Application Note # 149, Cermetek Internet Service (ISP) Description of Features and Services, for more details.
The CH2165 can utilize any non-proprietary commercial or private ISP for internet access as well as the Cermetek iModem Network ISP. We recommend the Cermetek iModem Network ISP because of its machine friendly features and low cost $2.00 per month access. Please see www.imodem.net
for more details.
iMODEM CONTROL METHODOLOGIES
The iModem receives @T® commands from the host processor or receives an event status flag on the Send Email Control Pin (Pin #6 – CH2124/60) and proceeds to dial up the local POP, log on to the internet, authenticate and verify the user ID and password, and either sends or retrieves email depending on the command/status flag received. For CH2124/60 products, see Table 1 for a summary of available @T
®
commands. For CH2165 products, see Table 2.
The iModem Family offers a variety of internet communication features ranging from simple on demand event triggered email transmission to full send and retrieve email capability. User Control of the internet communication activity of the iModem device typically falls into one of the following basic control strategies:
1. Fully Autonomous or event driven pin control requiring no host processor intervention. A pre­stored message is sent on a pin transition (CH2124/60).
2. Semiautonomous control, requiring one command to be issued from the host processor. A pre-stored message is sent on command.
3. Complete host intervention and supervision requiring each command to be issued from the host. Message is constructed and sent in real time.
Cermetek Microelectronics, Inc. High Speed Internet Modem Family
2003 Cermetek Microelectronics, Inc. Page 4 Document No. 607-0017 Revision H2 (11/03)
Figure 2. Functional Block Diagram of Cermetek CH21XX iModem Products. Note the additional RAM and ROM provided in the CH2165 iModem product.
Fully Autonomous On Demand Event Driven Control: CH2124/60. This is the simplest method of
operational control. Application of a 50ms TTL Low going pulse or level to the Send Email Control pin (Pin # 6) will cause the CH2124/60 iModem to send an email using its internal internet configuration profile. This profile is pre-programmed at the factory and can be modified by the user as necessary. No host processor intervention is required. The DTE serial interface is not required for fully autonomous on demand or event driven control. The CH2124/60 iModem will abort email related activities and return to the idle state if a low going TTL pulse is presented to the SEND Email Control Pin (Pin # 6) at any time during or after initiation of email send.
Semi-Autonomous Control: CH2124/60. This method requires a minimal amount of host processor intervention and requires that the DTE serial port be operational. Semi-autonomous control is a special case of full Host Supervised Control and relies on the preprogrammed default internet configuration profile contained within the iModem. Initiation of an email activity occurs with the issuance by the host processor to the iModem the appropriate @T
®
command to
send/retrieve/delete email. PSTN dial-up, logon,
authentication and email transmission, retrieval, and/or deletion are performed automatically by the iModem in the same fashion as for the Fully Autonomous On­Demand control method described above.
Host Supervised Control: CH2124/60. This method is the most flexible, but requires issuance by the host processor of the necessary @T
®
commands in the required order from the host processor. When choosing an implementation scheme utilizing a host processor, the host controls the iModem by using Cermetek @T
®
commands. These commands are
similar to the standard Hayes AT command set.
Although the DTE serial port is required to be operational for this method of control, an additional feature of this method is the ability of the host to over­ride the preprogrammed parameters (including the email message content) by simply entering the applicable information using the appropriate @T
®
Command.
Delete Email: CH2124/60. The user may selectively delete any email message (by specifying the message number) or delete all messages cached on the POP3 server.
PSTN
Input 1
Input 2
SEND EMAIL CONTROL PIN
INPUT
SENSE
AND
OUTPUT
PINS
Interface
Circuitry
SERIAL
INTERFACE
V-24
EIA-232-E or
UART
MODEM
V.90 (CH2160/65) V.22bis (CH2124)
MODEM INTERFACE
DAA
CH21XX
RXD RTS
DCD DSR
RI
CTS TXD
DTR
TIP
Ring
EMAIL ACCEPTED INDICATOR PIN
Flash ROM
32Kx8
(CH2124/60)
Network Protocol
SMTP
TCP
IP
PPP
POP 3
µ
P
RST
SPK
+5V
GND
Flash ROM
2Mx8
(CH2165)
RAM
8Mx8
(CH2165)
Cermetek Microelectronics, Inc. High Speed Internet Modem Family
2003 Cermetek Microelectronics, Inc. Page 5 Document No. 607-0017 Revision H2 (11/03)
Email and Internet Activity Status: CH2124/60. The CH2124/60 provides activity status messages on the iModem’s serial port. These status messages consist of a series of ASCII characters. Some examples are: BAD MESSAGE NUMBER, CONNECT, HANGING UP, MESSAGE ACCEPTED, MESSAGE DELETED. For a more detailed discussion of CH2124/60 status messages, refer to Cermetek Application Note # 155,
@T
®
Command Set Description and Usage For
CH2124/60 iModems.
Send Email: CH2165. To send email messages, the user must explicitly open the TCP socket connection using the @TCP command. This command automatically dials the specified local access POP phone number, performs user authentication, establishes a PPP connection and obtains an IP address.
Once connected to the internet, the user may use one of two methods to send email messages: use pre­stored messages contained in resident memory or use streaming messages obtained in real-time from the CH2165’s DTE serial I/O port. In either case, multiple email destination addresses are allowed.
For the case of pre-stored messages, each message is associated with a user defined message name. The user enters the @TD=msgname command (where msgname is the message file name) and the CH2165 sends the email using the SMTP protocol.
For the case of streaming email, the user enters the @TD=0 command (where 0 is a reserved name and signals the CH2165 that streaming email is desired). The CH2165 then sends the appropriate SMTP email headers and prompts the user to supply the body of the message. The user presents as many ASCII characters as desired to the CH2165’s DTE serial port. When finished, the user must end the streaming input with a <CR>.<CR>. The CH2165 will then terminate the SMTP message and close the SMTP connection. If the SMTP inactivity timer limit is exceeded (currently set at 90 seconds), the CH2165 will automatically terminate the message and close the SMTP connection. To end the internet session, the user must explicitly close the TCP connection and terminate the PSTN dial-up phone call by entering the @TCT command.
When using pre-stored messages in resident memory, the user is responsible for message memory management and utilization. Exceeding the memory limits will cause memory wrap around and messages may become lost or corrupted.
Retrieve Email: CH2165. The CH2165 will retrieve email from POP3 servers complying with applicable internet governing RFCs. By executing the @TES command, the user may obtain an inventory listing
containing Subject Line and Message Number of all messages currently cached on the POP3 server. The user may selectively down load individual messages (by message number) or may retrieve all messages on the server. Messages retrieved are provided to the user on the iModem’s serial port and are not stored in CH2165 resident memory.
Delete Email: CH2165. The user may selectively delete any email message (by message number) or all messages cached on the POP3 server.
Email and Internet Activity Status: CH2165. Currently, the CH2165 provides two levels of internet and email status information. Using the @TCS=PPP command, the user can monitor all the internet PPP communication. Additionally, the user can determine internet connectivity status by issuing the @TCS=PING command. The @TCS=PING command causes the iModem to send four successive PING commands directly to the internet host. Responses from the host include Host IP address and connectivity information.
Back-up and Alternative POP access Phone Numbers. Cermetek iModem products allow usage of
an alternative local access POP phone number or, if available, a 1-800 number, should the iModem fail to connect to the primary POP. The user can establish the number of attempts made to the primary POP before the back up POP is attempted.
DESCRIPTION OF FUNCTIONAL BLOCKS AND DISCUSSION OF BASIC OPERATIONS
Each CH21XX iModem product consists of the following functional blocks:
1. µP controller with Network Protocols and Flash
ROM.
2. Serial interface buffer.
3. Input/Output interface circuitry.
4. Internal modem (V.90 or V.22bis).
5. Modem interface circuitry.
6. DAA (Data Access Arrangement) PSTN interface.
7. Additional Flash ROM (CH2165 only).
8. Additional RAM (CH2165 only).
Figure 2 contains a schematic drawing illustrating the interconnectivity of the various functional blocks comprising the CH21XX iModem products.
Each iModem performs the following internet connectivity functions automatically:
1. Dials local POP and Connects to ISP.
2. Authenticates user ID and logs onto the internet.
3. Sends (or Retrieves) email to (from) the server
address/name specified using the ISP’s SMTP (POP3) Mail Server.
4. Terminates ISP session after all data is sent (or
retrieved) (CH2124/60 only).
Cermetek Microelectronics, Inc. High Speed Internet Modem Family
2003 Cermetek Microelectronics, Inc. Page 6 Document No. 607-0017 Revision H2 (11/03)
5. The CH2124/60 sends an ASCII MESSAGE ACCEPTED activity response message and sends a TTL LOW Pulse to Pin 8 indicating that the ISP Mail Server has accepted the email message.
Control of the internet capabilities of the iModem can be either event driven or initiated and controlled by a system level host processor. Refer to Table 3 for a complete set of pin descriptions.
When not utilized in the internet connectivity role, the iModem will function as a standard analog modem.
KEY FEATURE
The user has complete control of the level of autonomy the iModem exercises in the user’s application. This is a unique feature of Cermetek’s iModem products.
µP Controller. The µP controller performs the required internet operations by interpreting each specific @T
®
command and executing the appropriate internet commands. The necessary internet protocol firmware is resident in flash ROM. The @T
®
commands function as an extension to the industry standard Hayes AT command set.
Internal Modem. The internal modem is used to establish a data connection with the ISP. The CH2160/65 contains a V.90 internal modem while the CH2124 contains a V.22bis internal modem. The internal modem can be controlled with Hayes AT commands and is compatible with industry standard communication software. Refer to Cermetek publication, AT Commands and S-Registers
, for a more detailed discussion of the Hayes AT commands supported by the iModem product family.
When operating in standard analog modem mode, the maximum Data Terminal Equipment (DTE)/Host system communication speed is established by the maximum speed available from the DTE/Host and is not limited by the iModem product.
IMPORTANT NOTICE
AS DELIVERED FROM THE FACTORY, all @T® command communication between the CH2160/65 (CH2124) iModem and the host processor is conducted over the serial interface at 57.6/19.2kbps (2400bps).
CH21XX DTE Speed. AS DELIVERED FROM THE FACTORY, the CH2160/65 iModem will only communicate with the DTE at 57.6/19.2 kbps and the
CH2124 at 2400bps. However, the user may modify the DTE speed with the appropriate @T
®
commands.
Refer to Application Note # 155, @T
®
Command Set Description and Usage For CH2124/60 or to Application Note # 325, @T
®
Command Set Description and Usage For CH2165. When the user changes the DTE communication speed to any speed other than the default value set of the factory, the user must ensure that the DTE supports the speed selected. Failure to do so could adversely affect communication with the iModem device or, worst-case, disable communication with the internal µP controller. Refer to Application Note # 158, Cermetek iModem Caveats and Definitions
,
for a more detailed discussion of this issue.
Refer to Cermetek’s High Speed Modem and FAX Family product data sheet for a complete Description of the internal modem’s capabilities and functions.
Serial Host Interface Buffer. The iModem utilizes a serial V.24 EIA 232-E 5V interface to communicate with the internal modem and to communicate with the internal µP.
Telephone Line Interface or DAA. The iModem family includes a unique low distortion DAA designed for optimal performance over all PSTN line conditions thereby achieving the most reliable and best performance PSTN connections.
The CH21XX iModem family is designed to meet North American telephone standards as set by FCC Part 68
IMPORTANT NOTICE
If the user wants to change the DTE/Host communication speed to any speed other than the factory set speed of 57.6/19.2kbps for the CH2160/65 or 2400bps for the CH2124, the user must first change the DTE speed of the iModem using the appropriate all @T® commands before changing the DTE/Host speed. Refer to Application Note # 158, Cermetek iModem Caveats and Definitions, for a more detailed discussion of this issue.
(USA) and CSA CS-03 Part I (Canada). Each iModem product is shipped from the factory with an FCC label indicating the FCC registration number and ringer equivalent. The PSTN line interface is UL1950 and CSA listed. Consequently, the iModem family of products satisfies U.S. and Canadian requirements, and will meet other international approval agency requirements that specify these levels of isolation.