Critical Environment Technologies YESAIR Operation Manual

YESAIR
8-Channel IAQ Monitor
www.critical-environment.com
Rev. K | 2018.02 | For instrument firmware version 3.2.3 & up.
Rev. K | 2018.02 YESAIR Operation Manual
2 © 2018 All rights reserved. Data subject to change without notice.
TABLE OF CONTENTS
1 POLICIES ............................................................................................... 4
1.1 Important Notes .......................................................................................... 4
1.2 Warranty Policy ........................................................................................... 4
1.3 Service Policy ............................................................................................. 5
1.4 Copyrights ................................................................................................... 5
1.5 Disclaimer ................................................................................................... 6
1.6 Revisions .................................................................................................... 6
2 INTRODUCTION .................................................................................... 7
2.1 Contents ..................................................................................................... 7
2.2 General Description .................................................................................... 8
2.3 Key Features ............................................................................................... 9
3 INSTRUMENT SPECIFICATIONS ...................................................... 10
3.1 Technical Specifications ........................................................................... 10
3.2 Enclosure Dimensions .............................................................................. 12
4 SENSOR SPECIFICATIONS ............................................................... 13
4.1 Overview ................................................................................................... 13
4.2 Plug & Play Sensor Gas Types ................................................................. 14
5 FEATURES & FUNCTIONS ................................................................ 16
5.1 Front View ................................................................................................. 16
5.2 Bottom View .............................................................................................. 17
5.3 Left Side View ........................................................................................... 17
5.4 Rear View ................................................................................................. 19
5.5 Top View of YESAIR Pump Model ............................................................ 20
5.6 Top View of YESAIR Diffusion Model ....................................................... 21
6 OPERATION ........................................................................................ 21
6.1 Initial Startup Instructions (with included rechargeable batteries) ............. 21
6.2 Display and Buttons .................................................................................. 22
6.2 Switching Instrument On & Off .................................................................. 23
6.3 Battery & Battery Warnings ....................................................................... 23
6.4 Main Menu Function ................................................................................. 25
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 3
7 MENU FUNCTION DETAILS ............................................................... 26
7.1 Calibrate Menu .......................................................................................... 26
7.2 Settings Menu ........................................................................................... 27
7.3 Datalog Menu ............................................................................................ 30
7.4 Alarm Menu ............................................................................................... 33
7.5 Info Menu .................................................................................................. 34
7.6 USB Menu................................................................................................. 34
8 CALIBRATION PROCEDURES .......................................................... 34
8.1 Requirements & Cautions ......................................................................... 35
8.2 Calibration Process: Zero ......................................................................... 35
8.3 Calibration Process: 3-Point Span (For CO2 sensors only) ....................... 37
8.4 Calibration Process: 1-Point Span ............................................................ 38
9 ADDING OR CHANGING PLUG & PLAY SENSORS ........................ 39
9.1 Dummy Sensor Plugs ............................................................................... 41
9.2 Sensor Location Restrictions .................................................................... 42
10 YESAIR DUAL PROBE MODEL ....................................................... 43
10.1 Probes .................................................................................................... 44
10.2 Instrument Kits for Dual Probe Applications ............................................ 45
10.3 Application Setup and Configuration ....................................................... 46
11 INSTALLING THE YES VIEWER SOFTWARE ................................ 47
12 MENU ARCHITECTURE ................................................................... 48
13 MAINTENANCE ................................................................................. 49
14 TROUBLE SHOOTING ...................................................................... 49
15 ACCESSORIES ................................................................................. 50
15.1 External Battery Pack for Extended Operation........................................ 50
15.2 YESAIR Pump Handheld Gas Sample Probe ......................................... 50
15.3 YES Logger Package .............................................................................. 51
15.4 YES Viewer Software .............................................................................. 51
Rev. K | 2018.02 YESAIR Operation Manual
4 © 2018 All rights reserved. Data subject to change without notice.
1 POLICIES
1.1 Important Notes
Read and understand this manual prior to using this instrument. Carefully read the warranty policy, service policy, notices, disclaimers and revisions on the following pages.
This instrument should be inspected and calibrated regularly by a qualified and trained technician.
This instrument has not been designed to be intrinsically safe. For your safety, do not use it in classified hazardous areas (explosion-rated environments).
This instrument is not intended for use in a clean room application.
INSTRUMENT SERIAL NUMBER:
________________________________________________________________
PURCHASE DATE:
________________________________________________________________
PURCHASED FROM:
________________________________________________________________
1.2 Warranty Policy
Critical Environment Technologies Canada Inc. (the manufacturer) warrants this instrument, (excluding sensors, battery packs, batteries, pumps and filters), to be free from defects in materials and workmanship for a period of two years from the
date of purchase from our facility. The sensors have a warranty period of one year on a pro-rated basis from the date of purchase from our facility. If the
product should become defective within this warranty period, we will repair or replace it at our discretion.
The warranty status may be affected if the instrument has not been used and maintained as per the instructions in this manual or has been abused, damaged or modified in any way. This instrument is only to be used for purposes stated herein. The manufacturer is not liable for auxiliary interfaced equipment or consequential damage.
Due to ongoing research, development and product testing, the manufacturer reserves the right to change specifications without notice. The information
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 5
contained herein is based on data considered accurate. However, no warranty is expressed or implied regarding the accuracy of this data.
All goods must be shipped to the manufacturer by prepaid freight. All returned goods must be pre-authorized by obtaining a return merchandise authorization (RMA) number. Contact the manufacturer for a number and procedures required for product transport.
1.3 Service Policy
Critical Environment Technologies Canada Inc. (CETCI) maintains an instrument service facility at the factory. Some CETCI distributors / agents may also have repair facilities; however, CETCI assumes no liability for service performed by anyone other than CETCI personnel.
Repairs are warranted for 90 days after date of shipment (sensors, pumps, filters and batteries have individual warranties).
Should your instrument require non-warranty repair, you may contact the distributor from whom it was purchased or you may contact CETCI directly.
Prior to shipping equipment to CETCI, contact our office for an RMA #. All returned goods must be accompanied with an RMA number.
If CETCI is to do the repair work, you may send the instrument, prepaid, to:
Attention: Service Department Critical Environment Technologies Canada Inc. Unit 145, 7391 Vantage Way Delta, BC, VGN 1M3
Always include your Returned Merchandise Authorization (RMA) number, address, telephone number, contact name, shipping / billing information, and a description of the defect as you perceive it. You will be contacted with a cost estimate for expected repairs, prior to the performance of any service work.
For liability reasons, CETCI has a policy of performing all needed repairs to restore the instrument to full operating condition.
Pack the equipment well (in its original packing if possible), as we cannot be held responsible for any damage incurred during shipping to our facility.
1.4 Copyrights
This manual is subject to copyright protection; all rights are reserved. Under international and domestic copyright laws, this manual may not be copied or translated, in whole or in part, in any manner or format, without the written permission of CETCI.
Rev. K | 2018.02 YESAIR Operation Manual
6 © 2018 All rights reserved. Data subject to change without notice.
All software which CETCI utilizes and / or distributes holds a proprietary interest and is also subject to copyright protection and all rights are reserved. No party may use or copy such software in any manner or format, except to the extent that CETCI grants them a license to do so. IF THIS SOFTWARE IS BEING LOADED ONTO
MORE THAN ONE COMPUTER, EXTRA SOFTWARE LICENSES MUST BE PURCHASED.
Reference important notes under 1.1 Important Notes and 6.2 Switching
Instrument On / Off.
1.5 Disclaimer
Under no circumstances will CETCI be liable for any claims, losses or damages resulting from or arising out of the repair or modification of this equipment by a party other than CETCI Service Technicians, or by operation or use of the equipment other than in accordance with the printed instructions contained within this manual or if the equipment has been improperly maintained or subjected to neglect or accident. Any of the forgoing will void the warranty.
Under most local electrical codes, low voltage wires cannot be run within the same conduit as line voltage wires. It is CETCI policy that all wiring of our products meet this requirement. It is CETCI policy that all wiring be within properly grounded (earth or safety) conduit.
1.6 Revisions
This manual was written and published by CETCI (the manufacturer). The manufacturer makes no warranty or representation, expressed or implied including any warranty of merchantability or fitness for purpose, with respect to this manual.
All information contained in this manual is believed to be true and accurate at the time of printing. However, as part of its continuing efforts to improve its products and their documentation, the manufacturer reserves the right to make changes at any time without notice. Revised copies of this manual can be obtained by contacting CETCI or visiting www.critical-environment.com.
Should you detect any error or omission in this manual, please contact CETCI at the following address:
Critical Environment Technologies Canada Inc.
Unit 145, 7391 Vantage Way Delta, BC, V4G 1M3 Canada
Toll Free: +1.800.940.8741 Tel: +1.604.940.8741 Fax: +1.604.940.8745 Website: www.critical-environment.com
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 7
In no event will CETCI or its officers or employees be liable for any direct, special, incidental or consequential damages resulting from any defect in any manual, even if advised of the possibility of such damages.
2 INTRODUCTION
2.1 Contents
This checklist ensures that you have received everything required to run your IAQ monitor / logger.
If you do not receive any of the items listed below, contact the factory immediately:
YESAIR multi-gas monitor / logger
AC wall adapter 6 V @ 850 mA
Nickel-metal hydride rechargeable batteries (3 x “AA”)
Battery cover
Calibration tubing with fitting
Operation Manual
YES Viewer Data Logging Software (optional)
Communications cable (optional)
Extended battery pack (optional)
DATE:
________________________________________________________________
CHECKED BY:
________________________________________________________________
Rev. K | 2018.02 YESAIR Operation Manual
8 © 2018 All rights reserved. Data subject to change without notice.
2.2 General Description
Thank you for purchasing our YESAIR, a multi-sensor, battery powered, handheld air quality detection and data logging instrument designed for intermittent or continuous indoor air quality monitoring. It can be handheld, fixed to a wall or set on a desk or tripod.
The YESAIR is available three models:
YESAIR Pump that draws in sample air through a nozzle with an internal pump on the top of the unit.
YESAIR Diffusion that works by sample air passing through the sensor openings by natural circulation of air on top of the unit.
Dual Probe that draws in sample air using the internal pump, through an attached temperature and relative humidity probe and high humidity gas probe. This model is specifically for CO
2
and O2 sampling in high humidity environments such incubator chambers and horticultural applications (greenhouses, mushroom farms, etc).
NOTE: Specific Dual Probe model information can be found in Section 10 in this manual. The rest of this manual is devoted to the Pump and Diffusion models and shared specifications of all three models.
The Pump and Diffusion YESAIR models are equipped with a top mounted temperature and relative humidity sensor to aid in verifying readings, providing a comprehensive indication of air quality. The Dual Probe model comes with a handheld temperature/relative humidity probe and a high humidity gas sampling probe, both of which attach to the top of the instrument.
Sensor readings, battery level and data logging status can be viewed live on the multi-line, backlit, LCD display. The YESAIR can reliably record time-based
information, which can be downloaded via a USB port. Any computer capable of running Microsoft Windows 2000 or higher (with an available USB communications port) can accommodate CETCI’s proprietary YES Viewer Software. The YES Viewer Software allows users to analyze and graph the data.
In addition to the temperature and RH sensors, the YESAIR can handle up to 5 additional internal plug & play sensors consisting of a maximum of 3 electrochemical toxic gas or oxygen sensors, and 2 high current draw sensors such as an infrared PID or catalytic sensor, plus 1 remote particulate sensor such as the YESDUST. Choose from a selection of up to 30 different sensors to best suit your application specifications. Reference the list of available sensors under 4.2 Plug &
Play Sensor Gas Types.
Most of the sensor modules can be changed in the field and are operable within minutes (accurate readings will require more time as each sensor type has a
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 9
different warm up / stabilization period before they are able to perform to publish specifications).
An optional gas sampling probe is available with the Pump model. The probe has a 10 in / 25.4 cm wand and 30 in / 76 cm of tubing that fits onto the nozzle and allows you to reach into areas that are difficult to access.
Calibration and repairs are available at our manufacturing facility and through some of our authorized and trained Distributors.
If after reading through this manual, you have any questions, please do not hesitate to contact our Service Department for technical support.
2.3 Key Features
Light weight, contoured and comfortable to hold.
Flame rated ABS / Polycarbonate enclosure.
Displays readings for all installed sensors simultaneously on backlit LCD
display.
Multi-function, easy to use menu.
Operates from nickel metal hydride (NiMH) rechargeable batteries
(standard), or alkaline batteries, or continuously from the plug-in power adapter.
Hangs on a wall (rear slot molded in), mounts on a camera tripod or sits on
a desk.
Accommodates a standard cable lock for securing the instrument in place.
Samples air with an internal sample draw pump or by diffusion.
Accommodates electrochemical, catalytic, PID or infrared sensor types.
30 different plug & play sensors available to choose from.
Logs and stores information and events on an internal 2GB memory card
USB data downloading and auxiliary up loading capability from remote
probes
Optional YES Viewer software is Windows XP, VISTA, 7, 8 & 10 compatible
Rev. K | 2018.02 YESAIR Operation Manual
10 © 2018 All rights reserved. Data subject to change without notice.
3 INSTRUMENT SPECIFICATIONS
3.1 Technical Specifications
MECHANICAL
Enclosure Rugged ABS / Polycarbonate (UL94 rated)
Weight 567 g / 20 oz
Size 7.8” x 3.1” x 3.9”/ 197 mm x 78 mm x 98 mm
Covers
Sensor cover (removable; top of enclosure) Battery cover (removable; bottom of enclosure)
Security Slot for cable lock (lower right side)
ELECTRICAL
Power Standard
Optional
Continuous
Rechargeable 3.6 V NiMH battery pack (8 hours continuous operation time c/w plug-in battery charger / wall adapter (100 - 240 V, 50 - 60 Hz). Note: A “protection diode” in the circuit provides safety protection when the batteries are accidently inserted with reversed polarity.
Alkaline AA batteries x 3 See section 6.3 Battery & Battery Warnings.
Plug-in, 6VDC, Class-III, 2 A DC max. wall adapter
Sampling Modes
Pump
Diffusion
Internal, automatic sample pump draws in sample of target environment. (Pump and Dual Probe models)
Sample air is diffused naturally over the sensors for quick, direct reading. (Diffusion model)
Memory
> 1 million data points data logging to SD memory card (optional)
Calibration Automated through keypad
Information Recording
12 bit, multi-channel, user configurable with removable 2GB SD memory card.
Optional YES Logger package includes: 2GB SD memory card and card reader, 6 foot USB cable and YES Viewer software.
Circuit Microprocessor, user configurable.
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 11
Communication
Miniature USB port for changing settings and configuring logging functions and auxiliary port for using a remote sensor (i.e. YESDUST)
USER INTERFACE
Display Back-lit, multi-line LCD alphanumeric display
Buttons
3 tactile push buttons with audible sound for user access
Audible
Internal 80 Db @ 4ft / 1.2 m. One set point adjustment. Audible can be switched off through menu.
ENVIRONMENTAL (sensor dependent)
Operating Temperature 5°C to 50°C (41°F to 122°F)
Operating Humidity 0 - 99% RH non-condensing
Storage Temperature -20°C to 60°C (-4°F to 140°F)
Storage Humidity 0 - 99% RH non-condensing
CERTIFICATION
CE Certified
CE standards for safety: I .S. EN61010-1:2001 (Ed.2) CE standards for emissions: EN 50270:2006 CE standards for immunity: EN 50270:2006
Flammability UL94 rating
YES Viewer Data Logging Software (Optional)
Minimum system requirements to operate the optional YES Viewer Data Logging Software:
Descriptions
Microprocessor
Personal computer with Pentium III class processor or better
RAM
512MB RAM (minimum)
Operating System
Windows XP, Vista, 7, 8 or 10
Disk Space
At least 1 MB of available disk space. Additional space is required to store logger files and graph files.
Interface
An available USB port
Rev. K | 2018.02 YESAIR Operation Manual
12 © 2018 All rights reserved. Data subject to change without notice.
3.2 Enclosure Dimensions
3.06 (7.8 cm)
7.8” (19.8 cm)
NOTE: The model
shown is the YESAIR. The Dual Probe model dimensions are the same.
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 13
4 SENSOR SPECIFICATIONS
4.1 Overview
The YESAIR has the capacity for 7 internal sensors – one temperature sensor, one RH sensor and 5 plug and play gas sensors; plus one remote sensor such as the YESDUST Particulate Sensor.
The YESDUST is connected via the auxiliary port and is a general purpose particulate sensor that counts particulates between 1 and 10 microns in size. The YESDUST uses the YESAIR’s data logging capabilities to record data and adds this information to the log file along with the YESAIR’s data records. If you would like more information on the YESDUST please visit our website.
NOTE: Neither the YESAIR nor the YESDUST are intended for use in clean room applications.
The YESAIR has plug and play smart sensors and placement of those sensors is an important consideration. With the display facing you, look at the top of the YESAIR and you will see five gas sensor sockets. The three sockets closest to the back edge are for electrochemical toxic gas sensors, with SLOT 2 configured specifically for an Oxygen sensor. SLOTS 4 and 5, towards the front edge are for CO2, PID or combustible gas sensor types. If a Nitric oxide (NO) sensor requiring electronic bias within the circuit is used, it must be fitted to one specific sensor location (left rear position, determined by looking at the front of the instrument). Two sensors requiring bias cannot be fitted in the same instrument at the same time. Reference the photo in 9.2 Sensor Location Restrictions.
Sensors can be added or changed as required. However, an instrument that is configured for Nitric oxide, Hydrogen chloride, Ethylene oxide, Hydrazine or Formaldehyde cannot be swapped with a different sensor type without hardware modification and cannot be placed in any other socket than SLOT 1 or 3. If this change is desired, the unit needs to be sent back to the factory to be reconfigured.
Sticky gas sensors (ie. Chlorine (Cl
2
), Hydrogen chloride (HCl), Ozone (O3),
Hydrogen fluoride (HF), Fluorine (F
2
)) used in the Pump model should be installed in SLOT 1, closest to the inlet port for calibration. The shorter the distance the sticky gas needs to travel, the more accurate the calibration will be.
If the YESAIR is ordered with only a couple gas sensors, the unused sockets will be populated with a dummy sensor plug to ensure a good seal and circulation of air for sensing purposes. The dummy sensor plugs can be removed and replaced with gas sensors as mentioned above, and vice versa. To remove a dummy sensor plug, gently push inwards and turn, releasing the plug from the socket. See section 9.1 Dummy Sensor Plugs.
Rev. K | 2018.02 YESAIR Operation Manual
14 © 2018 All rights reserved. Data subject to change without notice.
4.2 Plug & Play Sensor Gas Types
SENSOR TYPE RANGE
PRODUCT
CODE
Carbon dioxide (CO2) IR 0 - 5,000 ppm PNP-A+
Carbon dioxide (CO2) IR 0 - 10,000 ppm PNP-A1
Carbon dioxide (CO2) IR 0 - 20% volume PNP-A2
Carbon dioxide (CO2) IR 0 - 5% volume PNP-B
Carbon dioxide (CO2) IR 0 - 100% volume PNP-B1
Methane (CH4) IR 0 - 5% volume PNP-B+
Ammonia (NH3) EC 0 - 50 ppm PNP-H
Arsine (AsH3) EC 0 - 2 ppm PNP-R
Carbon monoxide (CO) EC 0 - 50 ppm PNP-C
Carbon monoxide (CO) EC 0 - 50 ppm PNP-C
Carbon monoxide (CO), H2 compensated for use in H
2
background
EC 0 - 50 ppm PNP-C1
Chlorine (Cl2) EC 0 - 5 ppm PNP-I
Chlorine dioxide (ClO2) EC 0 - 1 ppm PNP-J
Ethylene (C2H4) EC 0 - 200 ppm PNP-E1
Ethylene oxide (C2H4O) EC 0 - 20 ppm PNP-E2
Fluorine (F2) EC 0 - 2 ppm PNP-S
Formaldehyde (CH2O) EC 0 - 5 ppm PNP-Q
Hydrogen (H2) EC 0 - 1,000 ppm PNP-K
Hydrogen chloride (HCl) EC 0 - 30 ppm PNP-M
Hydrogen cyanide (HCN) EC 0 - 100 ppm PNP-N
Hydrogen fluoride (HF) EC 0 - 10 ppm PNP-O
Hydrogen sulphide (H2S) EC 0 - 50 ppm PNP-L
Nitric oxide (NO) EC 0 - 100 ppm PNP-E
Nitrogen dioxide (NO2) EC 0 - 5 ppm PNP-D
Oxygen (O2) EC 0 - 25% volume PNP-F
Ozone (O3) EC 0 - 1 ppm PNP-G
Phosphine (PH3) EC 0 - 1 ppm PNP-V
Silane (SiH4) EC 0 - 50 ppm PNP-W
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 15
Sulphur dioxide (SO2) EC 0 - 20 ppm PNP-P
Combustibles (CH4, H2, C3H8) CAT 0 - 100% LEL PNP-X
TVOCs PID 0 - 300 ppm PNP-Y+
TVOCs PID 0 - 30 ppm PNP-Z+
Legend:
EC Electrochemical CAT Catalytic IR Infrared PID Photo Ionization Detector
NOTES:
1. Not all of the above sensors are available from stock. Delivery time for sensors
ordered will vary depending on which sensors are ordered, how many are ordered and measurement range desired.
2. Other measurement ranges are available for some sensors. Contact factory
with desired range to confirm availability.
3. Some of these sensors must be calibrated with correlation gases because they
are more readily available. If the customer wishes them to be calibrated with the exact target gas, extra charges will apply to acquire the specific gas if and when available. In these cases, customer will be required to take delivery of the special cylinder of span gas and dangerous goods and shipping costs will apply.
4. Some of the above sensors have cross sensitivities to other gases (interfering
gases). Please refer to the sensor specification chart before ordering a specific sensor if your application may have some of the interfering gases present.
Rev. K | 2018.02 YESAIR Operation Manual
16 © 2018 All rights reserved. Data subject to change without notice.
5 FEATURES & FUNCTIONS
5.1 Front View
NUMBER FEATURE FUNCTION
Temperature / RH Sensor Shroud (Pump and Diffusion models only)
Protects from everyday ruggedness and responds quicker to changes in RH and temperature.
Sensor Cover / Cap Keeps sensors secured inside device.
A
ir Vents For venting heat build-up from internal sensors.
A
udible Alarm
Internal 80 dB @ 4ft / 1.2 m. One setpoint adjustment. Can be disabled through the menu.
Lexan Label
Visually appealing, protects display, houses push buttons.
Digital Display
User interface; Multi-line, back-lit, LCD, alphanumeric display
Rubber Boot Cover
Covers the USB download slot, auxiliary upload slot and the SD memory card slot for data logging.
Cable Lock Slot
Secures cable lock similar to what is typically used for laptop computers.
Rev. K | 2018.02 YESAIR Operation Manual
© 2018 All rights reserved. Data subject to change without notice. 17
Keypad
3 tactile push buttons with audible sound to maneuver through display menu.
5.2 Bottom View
NUMBER FEATURE FUNCTION
Brass Thread For camera tripod mounting
Battery cover door Secures batteries in the device
5.3 Left Side View
Loading...
+ 37 hidden pages