1 Introduction
Figure 2.1: Sample System Layout
1.1 This guide contains brief configuration procedures for the GN-9284 CC-Link IE Field Basic Remote IO adaptor.
This adaptor functions as a slave on programmable logic controllers and other devices that function as a CC-Link IE Field
Basic master. For the purposes of this quick start guide, the focus will be on GX-Works3 compatible products like the iQF and iQ-R PLCs.
2 Example System Layout
2.1 This section is a system example that will be utilized for this guide. For simplicity, the system will be limited to a
master PLC and a single slave GN-9284 adaptor.
PLC: FX5UC-32MT/DSS-TS
Remote IO: GN-9284
Slice #1: GT-1238 8 pt, IN
Slice #2: GT-2328 8 pt, OUT
Slice #3: GT-3424 4 pt, Analog IN
Slice #4: GT-4424 4 pt, Analog OUT
Page 2
![](/html/58/586a/586a3728df7d56c4c78e334189d12bf8bb1235d3b7eee47bf378c9b519b73d14/bg3.png)
Figure 3.1: Adaptor Power Connections
Figure 4.1: Register Profile
3 Connections
3.1 Wire the system and field power as in Figure 3.1.
4 Register Profile
4.1 Download the GN-9284 CSPP profile and register in GX-Works3.
Tool Profile Management Register